  Only hard drives and CD / DVD rom in which there is still a mechanical mechanism, but both devices are still said to be electronic devices. Electronic devices process signals through electronic circuits that work together / integrated in a system. 


                  Use the CD-ROM drive as a audio CD player without the computer


Most of the CDROMS available have an Audio-Out Output to either plug in the headphones or connect it to an amplifier.
This circuit enables one to use the CDROM as a stand alone Audio CD player without the computer.

This circuit is nothing but a power supply which supplies +5v, +12V and Ground to the CDROM drive and hence can be used without the computer.
You should buy a D-type power connecter to connect this circuit’s outputs to the CDROM.
The details of the D connector are shown along with the circuit diagram.

Note that the D-connector goes into the CDROM in only one way and hence prevents any damage due to wrong connection.
Ensure that the 12V(yellow) wire is connected to the right of the D-connector(as seen from behind ,i.e the connector holes away from you with the curved portion of the connector upwards)

As soon as an Audio CD is inserted, the CD begins to play. To move to the next track, press the Skip-Track button on the CDROM front Panel.


   



   Stock Photo - Circuit board of CD ROM drive
Circuit board of CD ROM drive Stock Photo - 4355326  
Circuit board of CD ROM drive  
 
 
      CD-ROM Generator   
 
   Hasil gambar untuk electronic circuit cd room  
 
 
 
                                              Working of DVD Player  
 
 


   WORKING OF DIGITAL VERSATILE DISC (DVD)
Now we are going to look at how a DVD player works and the essential components for its working.

Parts of a DVD Player

The DVD player is not only used for playing the data present in a DVD, but also to write the content onto a DVD. To know this process it is essential to know the basics of a DVD.
As told earlier, DVD’s have pits and bumps in their track which holds the information that is required to be played. This information can be a video, audio or a mixture of both. When a DVD player reads this data, the smooth surface is usually taken as a ‘0’ and pits are usually taken as a ‘1’.
In order to create as well as read these data, a red laser with a wavelength of 600 nanometers. This is about 180 nanometers lesser than the wavelength of CD, which enables it to have a higher density of pits. Thus the size of the DVD increases. Though the first released DVD’s were only a single layer, 2 layered discs have been released nowadays. Single layer can hold only up to 4.7 GB of data while double layered DVD can hold up to 17 GB of data. The DVD design is similar to a CD a reflective silver layer in the centre and a semi-transparent gold layer on the top of it.
A DVD does not have the capacity to hold hi-def movies. So a MPEG-2 compression system is introduced. As this is used, the data will be encoded onto the DVD as elements of the changing frames. This has to be successfully decoded and decompressed by the DVD player.
Thus the parts of a DVD player are

1. Disc drive mechanism

The disc drive mechanism consists of a motor that will drive the disc in a circular motion. The mechanism will also have a disc feed – a loading tray that is used to accept the DVD from the user. Thus the entire disc drive is basically a spindle that holds the disc and a motor that is used to circle the disc. The spindle is held in its position with the help of small gears and belts that are attached internally. Some players have an automatic feed system in which, there will be no tray. Instead the disc will be automatically recognized after inserting a part of it.

2. Optical system

The optical system mainly consists of the laser beam, lenses, prism, photo-detectors and also mirrors. The output of this mechanism will be the input for the disc-drive. The laser beam will be a red laser diode which works at a wavelength of 600 nanometers. The optical system also requires a motor to drive it. The laser system and photo-detector is placed together on a single platform. The laser diode as well as other diodes is made with the help of glass.

3. Printed Circuit Board

The PCB is similar to that of any other electronic circuits. The electronic outline must be drawn on the PCB with the correct placement of all the IC’s resistors as well as capacitors. After the outline has been drawn, the components must be soldered to their respective places. All this must be done in a very clean environment so that the board does not become contaminated by dust. All the primary components of the electronic circuit should be made out of silicon.

Working of DVD Player

Take a look at the basic block diagram of how a DVD player works.

Block Diagram of DVD Player
Block Diagram of DVD Player
DVD Player-Block Diagram
DVD Player-Block Diagram
The pits and bumps in the DVD are hit by the laser from the optical mechanism of the DVD player. This laser will be reflected differently according to the change of pits and bumps. Though the laser hits a single spot, the DVD moves in a circular motion so that the entire area is covered. Mirrors are also used to change the spot.
These reflected laser beams are then collected by a light sensor (eg. photo-detector) which converts the different signals into a binary code. In short, the optical system helps in converting the data from the DVD into a digital code.
The binary signal is then sent to a Digital to Analog converter which will be setup in the PCB. Thus the corresponding analog signal of the DVD is obtained. The PCB also has amplifiers which amplify the signal and then sends it to the graphic and audio systems of the computer/TV. Thus, the corresponding audio/video signal is obtained. The basic working of a DVD player is shown below.
Working of DVD Player
Working of DVD Player

Assembling a DVD Player

As the different parts of the DVD player are all complicated electronic circuits, they are all manufactured by different people. They are later brought together and assembled at one place. During the assembling, the PCB will be connected to the rest of the machine and all the components are placed in the right positions. The whole package is then placed inside an outer plastic housing with a front panel with the buttons for various operations. This DVD player is then sent to a packaging station where they are placed safely inside boxes along with the respective power cords, operating manual, installing disks and so on. They are then taken by the distributors to various shops and then sold to customers.

Cautions while assembling a DVD Player

A DVD player will only be satisfactory to a customer only if it has a high performance. The degree of quality varies according to the flaws in the assembling process. Thorough inspections in both the visual as well as electrical divisions must be done most of the time. Flaws in the positioning of the different components can also cause the player to become faulty. After manufacturing the DVD also, the working performance is tested. To see the adverse effects of these players in different temperatures, the tests will be carried out in excessive heat as well as humidity. Since most of the parts of a DVD player is made by suppliers, they rely on other companies for good quality. The DVD assemblers will set a minimum standard for the supplies that they buy from outside. This specification must be met by them. The lenses and mirrors should be highly polished and cleaned before placing them.
 
 
  
 
 
   
Fig. 4. Block diagram of CD player test configuration.  
                 
 
 Block diagram of CD player test configuration. ' from publication 'Automotive VHDL-AMS Electro-Mechanics Simulations' on ResearchGate, the professional network for scientists.
 
 
 concept cd and dvd room  is an inverted microscope with electronic focusing 
 
May be the word 'electronic' is a little confusing: indeed it's not a REAL electronic microscope, because electron beams aren't easily usable by amateurs. However the term is justified: all its components, lens excepted, are electronic devices: LED for lighting, CCD (webcam) to take pictures and the most amazing....: electronic focusing!! Another feature of interest: it's a cheap microscope you can make yourself and experiment with.  
 But what is the use of a such microscope: it's an inverted design, the objective is located UNDER the slide and illuminator above (long distance working distance). So you have more room on the stage to put large vials containing water or culture box and to access the cells for handling for example... Besides, objectives are never in contact with liquid... 
 But how will we make this microscope? You can obtain the main device from a discarded CD-ROM reader (or reader/writer**) which you can find for free in computer repair shops for example. When you disassemble such a component, you can see, near the CD axis, an assembly of 2 main parts: first an optical device, including a little plastic lens which can move up/down and front/rear using 2 groups of coils. Secondly and below the first, an aluminum block which includes one infrared laser diode lighting the lens through a semi-transparent mirror and at the bottom of the block, an optical sensor used to read the CD and ensure tracking. Note: often, in the laser light path, is located a little cylindrical part which is a diffusion grating. You can see an aspect of the grating in the righthand picture below (with a scale added for comparison). You can use the grating (3 mm diameter ) like a slide micrometer! The aluminum block has bearings which can slide on two steel rods when it follows CD tracks. ( ** Probably a discarded music CD or DVD player ... will work well too.) (Safety note: the CD-ROM device must not be powered up when disassembled as the laser maybe dangerous to view.) 
 
 
   
 
 You may have already understood that the lens will be the objective in our microscope. First, you must identify the terminals which are used to displace the up/down coil, which is the 'focusing' coil. In fact the coil acts like a loudspeaker coil...  
 
 
 
 
 It's not difficult to make the little accessory below to test pins in pairs: when the lens moves up (or down) you have found the usable coil. You can solder - with care - two little wires on the pins.  
 
 
 The coil resistance is around 8 ohms and working current around 100 mA: you must make an electronic circuit like that below (in fact a variable power supply!) to feed the coil. Lens displacement will be around 1 to 1,5 mm, controlled by the potentiometer. It's easier to use 2 x 4,5 volts batteries in series (9 volts), to replace the transformer, rectifiers and 1000 µF capacitor. If you want to displace the lens up AND down with the same potentiometer, you must use a bipolar power supply, and the circuit becomes more complex.  
 
 
 
 On the prototype, the slide is supported by a thin plate - here a printed circuit board - the distance between plate and lens must be adjusted with several washers on struts so that, with coil unpowered, focus is made 0,2 mm BELOW slide surface (slide thickness is often around 1,2 mm ). So you have more than 1 mm to focus on the sample. If you want to use homemade well slides (by gluing a coverslip below an 18 - 20 mm diameter tube for example), focus with the lens unpowered and the well must be made on bottom of the coverslip... Picture below is an example of design, lefthand picture with white led illumination (led located in small tube with 2 mm hole in bottom ) and in righthand picture there's an LED torch in place of the led...  
 
 
 
 
 Below is a schematic of the whole microscope: some features can be experimented with, for example: diaphragms with 1,5 to 2 mm hole in front of the LED and between lens and webcam, little lens in front of the led.... The webcam lens MUST be removed: avoid dust or particles falling on the CCD surface! A coverslip lightly glued on webcam thread is useful. 
  
 
 You can improve constrast by using a diaphragm (washer with 2 mm hole) below the lens: see picture below.  
 
 
 
 
 The equivalent magnification (ie: magnification of a real objective, if webcam was fitted on the 16 cm tube of a classical microscope) is between 6 times and 10 times according to distance: Lens - CCD (respectively 4 and 6 cm). A x6 magnification is quite ideal to explore quickly a sample and to pick the more interesting subjects with a micro pipette. 
 
 
 
 But probably you are impatient to see pictures! They are not equivalent to plan achromat objective pictures, of course: don't forget that the lens is a plastic lens!! But in the top righthand corner picture below, you can see ribs on butterfly scale! This picture is taken with x10 equivalent objective, all the others with x6 equivalent objective. Pictures are not enhanced nor retouched. Subjectsinclude those from old slides mounted in glycerin gelly, some of them are colored with methylene blue.  
 
 
 
 Magnification is around X6 with CCD located 4 cm from the lens. All the CCD field of view is covered by the beam. If CCD is moved 6 cm from lens, the magnification becomes a x10 objective equivalent but beam overflow field of CCD.  
 
 
 
 
 The results are interesting and probably can be improved if you try a more elaborate lighting assembly: for example with a small lens located 2 cm below LED: pictures taken with an LED torch are better. It's important to align correctly center of lens and CCD and be sure than lens CCD planes are parallel. If you want to improve focusing distance, you can use a bipolar power supply: in this case the lens displaces itself up and down in a range of + or - 1,5 mm and you can use deeper well slides. Note: don't discard steel rods used to guide aluminum block: you can use the block to fix the slide and move it in front of the lens (a kind of half X-Y stage!!)  
 At this point, another idea could be developed: a portable inverted microscope, batteries powered to observe sample on land, Something like McArthur Open University microscope, but a little more rustic...It could be designed according schematic below,.... maybe a future article?! 
 If some readers are interested in experimenting with these devices, please don't hesitate to contact me...
Comments to the author Jean-Marie Cavanihac are welcomed.
 
 
 
 
 
 
 
 
      Generic Optical Tweezer Diagram 
 
      File:Generic Optical Tweezer Diagram.jpg 
 
  DIC Light Path 
 
   File:DIC Light Path.png  
 
   
OPT301 Laser Receiver Schematic


 
       Hasil gambar untuk electronic circuit cd room 
 
 
 

INTERNAL 24X DVD REWRITER WITH M-DISC™ SUPPORT

       

Key Features

  • Max. 24X DVD±R Write Speed
  • Super-Multi: CD-R/RW/DVD-R/-R/DL/-RW/+R/+R DL/+RW/RAM Read and Write Compatible, CD Family and DVD-ROM Read Compatible
  • M-DISC Support
  • 0.5MB Buffer Memory
 
 
   

Superior data protection with M-DISC™ Support

The M-DISC™uses a patent rock-like recording surface instead of organic dye to etch your data onto a disc. The M-DISC has been tested and proven to outlast standard DVDs currently on the market.

Silent Play

The Silent Play technology helps reduce noise during playback by recognizing different multimedia and automatically adjusting the playback speed according to its criteria for optimal performance.

Super Multi Compatibility

LG Super Multi Compatibility optical drives can read and write different types of disc formats in one convenient package.
1. DVD+R 2. RW DVD-R 3. RW DVD-RAM
This gives you the option to choose the media best suited for each task 
 
 
 

Superior data protection with   

 

Introduction

Compact discs and the digital audio revolution

The transformation of CD players and CDROMs from laboratory curiosities to the economical household appliances that have revolutionized the musical recording industry and have made possible multimedia computing depend on the availability of two technologies: low power low cost solid state laser diodes and mass produced large scale integrated circuits. Without these, a CD player using 1960's technology would be the size of dishwasher!
Most of us take all of this for granted rarely giving any thought to the amazing interplay of precision optics and complex electronics - at least until something goes wrong. The purpose of this document is to provide enough background on CD technology and troubleshooting guidance so that anyone who is reasonably handy whether a homeowner, experimenter, hobbiest, tinkerer, or engineer, can identify and repair many problems with CD players and possibly laserdisc players, CDROM drives, and optical storage drives as well.
Even if you have trouble changing a light bulb and do not know which end of a soldering iron is the one to avoid, reading through this document will enable you to be more knowledgeable about your CD player. Then, if you decide to have it professionally repaired, you will have a better chance of recognizing incompetence or down right dishonesty when dealing with the service technician. For example, a bad laser is not the most likely cause of a player that fails to play discs - it is actually fairly far down on the list of typical faults. A dirty lens is most likely. There - you learned something already!

Scope of this document

This document was developed specifically for the troubleshooting and repair of the CD players in component stereo systems, compact stereos, boomboxes, car units and portables, as well as CDROM drives (including the Sony Playstation).
The primary differences between these types will relate to how the disc is loaded - portables usually are top loaders without a loading drawer or tray:
However, as a result of the level of miniaturization required for portables and to a lesser extent, CDROM drives, everything is tiny and most or all of the electrical components are surface mounted on both sides of an often inaccessible printed circuit board with the entire unit assembled using screws with a mind of their own and a desire to be lost.
For other types:

  • DVD (Digital Versatile - or Video - Disc) players (which are now widely available and will completely replace CD players in a few years), suffer from many of the same problems as CDs and Laser Discs. Thus, a familiarity with the operating and repair of current technology will give you a head start on the amazing wonders (and similarly amazing problems) to come. There is a great deal of information on DVD technology in the DVD FAQ. Electronics Now, December, 1997, has a nice article by Steven J. Bigelow covering everything from the DVD format to installing and using a DVDROM drive in your PC. While the digital processing of the data from a DVD is fundamentally different than that of a CD, the most likely failures are still in the optical pickup and front-end electronics. While details differ, the troubleshooting ends up being very similar.
  • BD (Blu-ray) and HD DVD players and recorders. Much of the information on CD and DVD technology applies to these next generation high capacity video and computer storage devices as well. These are now becoming mainstream, though when and if they will replace CD and DVD entirely is not known.
  • Laserdisc players and optical disk storage units have much in common with CD players with respect to the mechanical components and front-end electronics. Therefore, the information contained in this document can represent a starting point for their troubleshooting as well. However, they may include additional servo systems (optical pickup tilt, for example), as well as additional and/or different signal processing subsystems. See the document: Optical Disc Players and Optical Data Storage Drives.
Note that throughout this document, the term 'CD player' is used most often. However, it should be understood that in most cases, the information applies to CDROM drives, game machines using CDs like the Sony Playstation, laserdisc players, MiniDisk players/recorders, DVD players, and other types of optical disk systems. Also see the document specifically devoted to these other technologies: "Notes on the Troubleshooting and Repair of Optical Disc Players and Optical Data Storage Drives". Also, where I remember, the term 'disc' is used to denote a read-only medium (e.g. a regular audio CD or LD) while 'disk' is used for one that is recordable (e.g., CD-R or MiniDisk).
Note: Links to all the diagrams and photographs referenced from this document can be found in Sam's CD FAQ Files.

Types of problems found in CD players

Many common problems with CD players can be corrected without the need for the service manual or the use of sophisticated test equipment (though a reliable multimeter will be needed for any electrical tests and an oscilloacope of at least 5 MHz bandwidth is highly desireable for servo alignment and more advanced troubleshooting). The types of problems found in a CD player can be classified into several categories:

  1. Mechanical - dirt, lubrication, wear, deteriorated rubber parts, dirty/bad limit switches, physical damage. A dirty lens (coated with dust, tobacco smoke residue, or condensed cooking grease) - easily remedied - is probably the number one cause of many common problems: discs not being recognized, seek failure, audible noise, and erratic tracking, sticking, or skipping. Even many professionals may mistake (either accidentally or on purpose) these symptoms being due to much more serious (and expensive) faults. Don't be fooled! Cleaning of the lens and any other accessible optical components (usually only the turning mirror, if that) and a mechanical inspection should be the first things done for any of these problems (and as periodic preventive maintenance especially if the equipment is used in a less than ideal environment). See the section: General inspection, cleaning, and lubrication.
  2. Electrical Adjustments - coarse tracking, fine tracking, focus, laser power. However, some CD players no longer have some of these adjustments. The servo systems are totally digital - they either work or they don't.
  3. Power problems (mostly portables) - weak batteries, inadequate, defective, or improper AC wall adapter.
  4. Bad connections - broken solder on the pins of components that are stressed like limit or interlock switches, or audio or power jacks, internal connectors that need to be cleaned and reseated, broken traces on flexible cables, or circuit board damage due to a fall.
  5. Electrical Component Failure. These are rare except for power surge (storm and lightning strike) related damage which if you are lucky will only blow out components in the power supply. (Or, plugging a 3 V portable into the 12 V of your automobile. You can probably forget about this even being a CD player again.)
  6. Incompatible geographic location. :-) This doesn't really apply to CD players but may be a factor with equipment like Sony PlayStations and very likely with DVD players. In their infinite wisdom (or greed), manufacturers are including 'country codes' on the discs so that a game or movie sold in one place cannot be used in another. So, if you bought a disc on the other side of the world and it doesn't work at home, thank the lawyers.....
You can often repair a CD player which is faulty due to (1) or (2) except for laser power which I would not attempt except as a last resort without a service manual and/or proper instrumentation if needed - improper adjustment can ruin the laser. If discs are recognized at all or even if the unit only focuses correctly, then laser power is probably ok. While the laser diodes can and do fail, don't assume that every CD player problem is laser related. In fact, only a small percentage (probably under 10%) are due to a failure of the laser diode or its supporting circuitry. Mechanical problems such as dirt and lubrication are most common followed by the need for electrical (servo) adjustments.
The solutions to category (3) and (4) problems are obvious - but it may take a conscious effort to remember to check these out before assuming that the fault is due to something much more serious.
Category (5) failures in the power supply of component (AC line powered) CD players can also be repaired fairly easily.
Most other electrical failures will be difficult to locate without the service manual, test equipment, and a detailed understanding and familiarity with audio CD technology. However, you might get lucky. I have successfully repaired problems like a seek failure (replaced a driver chip because it was running excessively hot) and a door sensor failure (traced circuitry to locate a bad logic chip). Since so much of the intelligence of a CD player is in the firmware - the program code inside the microcontroller, even the schematic may be of only marginal value since I can pretty much guarantee that the firmware will not be documented. The service manuals rarely explain *how* the equipment is supposed to work - and then perhaps only in poorly translated Japanese!
You can pretty much forget about repairing electrical problems in portable equipment other than perhaps bad connections (usually around the audio or power jacks, internal connectors, interlock switch (since it is stressed), or elsewhere due to the unit being dropped). Nearly everything in a portable (and most CDROM drives for that matter though this is not quite as bad) is itty-bitty surface mount components. There is generally only minimal useful information printed on the circuit board. Tracing the wiring is a nightmare. Even the test points and adjustments may be unmarked!

Repair or replace?

While CD players with new convenience features are constantly introduced, the basic function of playing a CD has not changed significantly in 15 years. None of the much hyped 'advancements' such as digital filters, oversampling, one bit D/As, and such are likely to make any difference whatsoever in the listening pleasure of most mortals. The people who care, do so only because they are more concerned with the technology than the musical experience. Most of these so called advances were done at least in part to reduce costs - not necessarily to improve performance.
Therefore, unless you really do need a 250 disc CD changer with a remote control that has more buttons than a B777 cockpit and 2000 track programmability, a 10 year old CD player will sound just as good and repair may not be a bad idea. Many older CD players are built more solidly than those of today. Even some new high-end CD players may be built around a mostly plastic optical deck and flimsy chassis.
If you need to send or take the CD player or CDROM drive to a service center, the repair could easily exceed the cost of a new unit. Service centers may charge up to $50 or more for providing an initial estimate of repair costs but this will usually be credited toward the total cost of the repair (of course, they may just jack this up to compensate for their bench time). Parts costs are often grossly inflated as well - possibly due to a deliberate effort on the part of manufacturers to discourage repair of older equipment. However, these expensive parts do not really fail nearly as often as is commonly believed - the laser is not the most likely component to be bad! Despite this, you may find that even an 'authorized' repair center will want to replace the expensive optical pickup even when this is not needed. I do not know how much of this is due to dishonesty and how much to incompetence.
If you can do the repairs yourself, the equation changes dramatically as your parts costs will be 1/2 to 1/4 of what a professional will charge and of course your time is free. The educational aspects may also be appealing. You will learn a lot in the process. Thus, it may make sense to repair that bedraggled old boombox after all.
 
 

CD Digital Audio Technology

General Introduction to CD Technology

Information on a compact disc is encoded in minute 'pits' just under the label side of the CD. The CD itself is stamped in much the same way as an old style LP but under much more stringent conditions - similar to the conditions maintained in the clean room of a semiconductor wafer fab. The CD pressing is then aluminum coated in a vacuum chamber and the label side is spin-coated with a protective plastic resin and printed with the label.
CD-Rs - recordable CDs use a slightly different construction. CD-R blanks are prestamped with a spiral guide groove and then coated with an organic dye layer followed by a gold film, resin, and label. The dye layer appears greenish and deforms upon exposure to the focused writing laser beam to form pits and lands.
DVDs or Digital Versatile Disks (or Digital Video Disks depending on who you listen to) - implement a number of incremental but very significant improvements in technology which in total add up to a spectacular increase in information density - almost 10:1 for the same size disc. These include higher frequency laser (670 or shorter visible wavelength), closer track spacing, better encoding, and a double sided disc. According to early reports on the final specifications, DVDs will be able to store 8 times the audio of current CDs at a higher sampling rate and bit resolution, 2 hours of MPEG encoded high quality movies, and all kinds of other information. Raw data capacity is somewhere between 5 and 10 GBytes. See the section: Comparison of CD and DVD Specifications for additional information.
And the "Blu-ray" standard uses a blue-violet laser to achieve even higher capacity for multimedia and computer storage applications. See the section: Comparison of CD, DVD, BD Specifications

CD information storage and playback

The actual information to be recorded on a CD undergoes a rather remarkable transformation as it goes from raw audio (or digital data) to microscopic pits below the disc's surface. For commercial or professional audio recording, the process starts with pre-filtering to remove frequencies above about 20 kHz followed by analog-to-digital conversion, usually at a sampling rate of 48 K samples/second for each stereo channel. The resulting data stream is then recorded on multi-track digital magnetic tape. All mixing and pre-mastering operations are done at the same sampling rate. The final step is conversion through re-sampling (sample-rate conversion including some sophisticated interpolation) to the 44.1 K samples/second rate actually used on the CD (88.2 K total for both channels). (In some cases, all steps may be performed at the 44.1 K rate.)
That is followed by extremely sophisticated coding of the resulting 16-bit two's-complement samples (alternating between L and R channels) for the purpose of error detection and correction. Finally, the data is converted to a form suitable for the recording medium by Eight-to-Fourteen modulation (EFM) and then written on a master disk using a precision laser cutting lathe. A series of electroplating, stripping, and reproduction steps then produce multiple 'stampers', which are used to actually create the discs you put in your player (more below).
Of course, it is possible to create your own CDs with a modestly priced CD-R recorder (which does not allow erasing or re-recording). Now, re-writable CD technology with fully reusable discs enables recording and editing to be done more like that on a cassette tape
Like a phonograph record, the information is recorded in a continuous spiral. However, with a CD, this track (groove or row of pits - not to be confused with the selections on a music CD) starts near the center of the CD and spirals (counterclockwise when viewed from the label side) toward the outer edge. The readout is through the 1.2 mm polycarbonate disc substrate to he aluminized information layer just beneath the label. The total length of the spiral track for a 74 minute disc is over 5,000 meters - which is more than 3 miles in something like 20,000 revolutions of the disc!
The digital encoding for error detection and correction is called the Cross Interleave Reed-Solomon Code or CIRC. To describe this as simply as possible, the CIRC code consists of two parts: interleaving of data so that a dropout or damage will be spread over enough physical area (hopefully) to be reconstructed and a CRC (Cyclic Redundancy Check) like error correcting code. Taken together, these two techniques are capable of some remarkable error correction. The assumption here is that most errors will occur in bursts as a result of dust specs, scratches, imperfections such as pinholes in the aluminum coating, etc. For example, the codes are powerful enough to totally recover a burst error of greater than 4,000 consecutive bits - about 2.5 mm on the disc. With full error correction implemented (this is not always the case with every CD player), it is possible to put a piece of 2 mm tape radially on the disc or drill a 2 mm hole in the disc and have no audio degradation. Some test CDs have just this type of defect introduced deliberately.
Two approaches are taken with uncorrectable errors: interpolation and muting. If good samples surround bad ones, then linear or higher order interpolation may be used to reconstruct them. If too much data has been lost, the audio is smoothly muted for a fraction of a second. Depending on where these errors occur in relation to the musical context, even these drastic measures may be undetectable to the human ear.
Note that the error correction for CDROM formats is even more involved than for CD audio as any bit error is unacceptable. This is one of many reasons why it is generally impossible to convert an audio CD player into a CDROM drive. However, since nearly all CDROM drives are capable of playing music CDs, much can be determined about the nature of a problem by first testing a CDROM drive with a music CD.

CD (disc) construction

The information layer as mentioned above utilizes 'pits' as the storage mechanism. (Everything that is not a pit is called a 'land'.) Pits are depressions less than 0.2 um in depth (1/4 wavelength of the 780 nm laser light taking into consideration the actual wavelength inside the polycarbonate plastic based on its index of refraction). Thus, the reflected beam is 180 degrees out of phase with incident beam. Where there is a pit, the reflected beam from the pit and adjacent land will tend to cancel. This results in high contrast between pits and lands and good signal to noise ratio. In the far field (at the detector), the pit will appear dark and the land will appear breight. Pits are about 0.5 um wide and they come in increments of 0.278 um as the basic length of a bit (encoded, see below) on the information layer of the disc.
Each byte of the processed information is converted into a 14 bit run length limited code taken from a codebook (lookup table) such that there are no fewer than 2 or more than 10 consecutive 0s between 1s. By then making the 1s transitions from pit to land or land to pit, the minimum length of any feature on the disc is no less than 3*p and no more than 11*p where p is 0.278 um. This is called Eight-to-Fourteen Modulation - EFM. Thus the length of a pit ranges from 0.833 to 3.054 um.
Each 14 bit code word has 3 additional sync and low frequency suppression bits added for a total of 17 bits representing each 8 bit byte. Since a single bit is 0.278 um, a byte is then represented in a linear space of 4.72 um. EFM in conjunction with the sync bits assure that the average signal has no DC component and that there are enough edges to reliably reconstruct the clock for data readout. These words are combined into 588 bit frames. Each frame contains 24 bytes of audio data (6 samples of L+R at 16 bits) and 8 bits of information used to encode (across multiple frames) information like the time, track, index, etc:
                Sync                    (24 + 3).
                Control and display     (14 + 3).
                Data                    (12 * 2 * (14 + 3).)
                Error correction        ( 4 * 2 * (14 + 3).)
                                        --------------------
                                        588 total bits/frame
A block, which is made up of 98 consecutive frames, is the smallest unit which may be addressed on an audio CD and corresponds to a time of 1/75 of a second. Two bits in the information byte are currently defined. These are called P and Q. P serves a kind of global sync function indicating (among other things) start and end of selections and time in between selections. Q bits accumulated into one word made of a portion of the 98 possible bits in a block encodes the time, track and index number, as well as many other possible functions depending where on the disc it is located, what kind of disc this is, and so forth.
Information on a CD is recorded at a Constant Linear Velocity - CLV. This is both good and bad. For CD audio - 1X speed - this CLV is about 1.2 meters per second. (It really isn't quite constant due to non constant coding packing density and data buffering but varies between about 1.2 and 1.4 meters per second). CLV permits packing the maximum possible information on a disc since it is recorded at the highest density regardless of location. However, for high speed access, particularly for CDROM drives, it means there is a need to rapidly change the speed of rotation of the disc when seeking between inner and outer tracks. Of course, there is no inherent reason why for CDROMs, the speed could not be kept constant meaning that data transfer rate would be higher for the outer tracks than the inner ones. Modern CDROM drives with specs that sound too good to be true (and are) may run at constant angular speed achieving their claimed transfer rate only for data near the outer edge of the disc.
Note that unlike a turntable, the instantaneous speed of the spindle is not what determines the pitch of the audio signal. There is extensive buffering in RAM inside the player used both as a FIFO to smooth out data read off of the disc to ease the burden on the spindle servo as well as to provide temporary storage for intermediate results during decoding and error correction. Pitch (in the music sense) is determined by the data readout clock - a crystal oscillator usually which controls the D/A and LSI chipset timing. The only way to adjust pitch is to vary this clock. Some high-end players include a pitch adjustment. Since the precision of the playback of the any CD player is determined by a high quality quartz oscillator, wow and flutter - key measures of the quality of phonograph turntables - are so small as to be undetectable. Ultimately, the sampling frequency of 44.1 K samples per second determines the audio output. For this, the average bit rate from the disc is 4.321 M bits per second.
Tracks are spaced 1.6 micrometers apart - a track pitch of 1.6 um. (This is the nominal specification but may vary somewhat and will be less on those CDs that contain more than 74 minutes of music or 650 MB of data. However, unlike LPs, the pitch is not affected in the slightest by the content.) Thus a 12 cm disc has over 20,000 tracks for its 74 minutes of music. Of course, unlike a hard disk and like a phonograph record, it is really one spiral track over 3 miles long! However, as noted above, the starting point is near the center of the disc. The width of the pits on a track is actually about 0.5 um. The focused laser beam is less than 2 um at the pits. Compare this to an LP: A long long playing LP might have a bit over 72 minutes of music on two sides or 36 minutes per side. (Most do not achieve anywhere near this much music since the groove spacing needs to vary depending on how much bass content the music has and wide grooves occupy more space.) At 33-1/3 rpm, this is just over 1,200 grooves in about 4 inches compared to 20,000 tracks on a CD in a space of just over 1.25 inches! The readout stylus for an LP has a tip radius of perhaps 2 to 3 mils (50 to 75 um).

CD (disc) manufacturing

(From: Reinhart (Lasernut23@aol.com).)
An LP is pressure pressed using a solid vinyl biscuit. A CD, on the other hand, is not manufactured in this manner. CDs are replicated through injection molding, where molten polycarbonate is injected into a mold under high pressure. CDs *must* be manufactured in strict clean room environments. On a side note, when LaserDiscs were released to market by MCA DiscoVision in 1978, this requirement wasn't recognized, or ignored by MCA Corporate in an attempt to keep manufacturing costs of these silver platters down. The first discs were manufactured in an environment similar to an LP plant. As a result, the finished product, while looking visibly okay when observed casually, had major problems playing reliably on many LaserDisc players. Now, of course, we know better, although Pioneer recognized these requirements far more quickly than MCA. Even RCA's Videodisc plant for their needle-in-grove CED (SelectaVision Videodisc) format recognized these requirements better than MCA! CED's market introduction in 1981 did not start as catastrophically like LaserDisc did as a result.

And you thought driving on a narrow winding country road was tough!

To put the required CD player servo system performance into perspective, here is an analogy:
At a constant linear velocity of about 1.2 meters per second, the required tracking precision is astounding: Proper tracking of a CD is equivalent to driving down a 10 foot wide highway (assuming an acceptable tracking error of less than +/- 0.35 um) more than 3,200 miles for one second of play or over 14,400,000 miles for the entire disc without accidentally crossing lanes! Actually, it is worse than this: focus must be maintained all this time to better than 1 um as well (say, +/- 0.5 um). So, it is more like piloting a aircraft down a 10 foot wide flight path at an altitude of about 12 miles (4 mm typical focal length objective lens) with an altitude error of less than +/- 7 feet! All this while the target track below you is moving both horizontally (CD and spindle runout of 0.35 mm) 1 mile and vertically (disc warp and spindle wobble of up to 1 mm) 3 miles per revolution! In addition, you are trying to ignore various types of garbage (smudges, fingerprints, fibers, dust, etc.) below you which on this scale have mountain sized dimensions. Sorry for the mixed units. My apologies to the rest of the world where the proper units are used for everything).
The required precision is unbelievable but true using mass produced technology that dates to the late 1970s. And, consider that a properly functioning CD player is remarkably immune to small bumps and vibration - more so than an old style turntable. All based on the reflection of a fraction of a mW of invisible laser light!
Of course, this is just another day in the entertainment center for the CD player's servo systems. Better hope that our technological skills are never lost - a phonograph record can be played using the thorn from a rosebush using a potter's wheel for a turntable. Just a bit more technology is needed to read and interpret the contents of a CD!
And, for a DVD with its narrower longer track (0.74 um compared to 1.6 um and more than twice as long), it's even more of a challenge!

Why does focus need to be so precise?

Since a laser printer doesn't need to have so precise a focus (afterall, paper isn't that smooth), what's all this fuss about focusing with respect to CD, DVD, and other optical disc/k systems? Laser beams remain fairly parallel, no?
Wrong.
First, laser light that remains precisely parallel - doesn't diverge - only can be found in bad Sci-Fi. Laser light still obeys the laws of physics and in order to get the required spot size on the disc - about 1 micrometer (um), 1,000th of a mm, 1,000,000th of a meter, it needs to be focused precisely at the disc surface. Due to manufacturing tolerances for disc flatness (warp), the surface may move up-and-down as much as 100 times this amount. And disc height from player to player isn't that precise either. Large diameter laser beams can be kept quite parallel but a beam 1 um in diameter would diverge at about a 60 degree angle. The lens in the CD player has a focal length of about 4 mm and focuses the light from a beam a couple millimeters in diameter to a 1 um spot on the disc surface and because of the small depth of focus, the distance needs to be kept constant to 1 or 2 um. For DVD systems, the required precision is even greater.
Laser printers DO have focusing optics with correction for the flat surface (in one dimension) of the photosensitive drum. They don't need to be quite as precise because the spot size is much larger than for a CD or DVD player - a 1,200 dpi printer would have a spot on the order of 50 um. Therefore, the lens can be quite far away and the depth of focus is much larger. Thus, no active focusing mechanism is needed.

CD optical pickup operating principles

A diagram showing the major functional components of the three-beam optical pickup described below is available in PDF format: CDT3BP.
This design is typical of older optical pickups (though you may come across some of these). Newer types have far fewer individual parts combining and eliminating certain components without sacrificing performance (which may even be better). Additional benefits result is lower cost, improved robustness, and increased reliability. However, operating principles are similar.
The purpose of the optical pickup in a CD player, CDROM drive, or optical disk drive, is to recover digital data from the encoded pits at the information layer of the optical medium. (With recordable optical disks, it is also used to write to the disk medium.) For CD players, the resulting datastream is converted into high fidelity sound. For CDROMs or other optical storage devices, it may be interpreted as program code, text, audio or video multimedia, color photographs, or other types of digital data.
Most of the basic operating principles are similar for single-beam CD pickups and for pickups used in other digital optical drives.
It is often stated that the laser beam in a CD player is like the stylus of a phonograph turntable. While this is a true statement, the actual magnitude of this achievement is usually overlooked. Consider that the phonograph stylus is electromechanical. Stylus positioning - analogous to tracking and focus in an optical pickup - is based on the stylus riding in the record's grooves controlled by the suspension of the pickup cartridge and tone arm. The analog audio is sensed most often by electromagnetic induction produced by the stylus's minute movements wiggling a magnet within a pair of sense coils.
The optical pickup must perform all of these functions without any mechanical assistance from the CD. It is guided only be a fraction of a mW of laser light and a few milligrams of silicon based electronic circuitry.
Furthermore, the precision involved is easily more than 2 orders of magnitude finer compared to a phonograph. Sophisticated servo systems maintain focus and tracking to within a fraction of a micrometer of optimal. (1 um is equal to 1/25,400 of an inch). Data is read out by detecting the difference in depth of pits and lands of 1/4 wavelength of laser light (about 0.15 um in the CD)!

  • The laser beam is generated by a solid state laser diode emitting at 780 nm (near IR). Optical power from the laser diode is no more than a couple of mW and exits in a wedge shaped beam with a typical divergence of 10x30 degrees in the X and Y directions respectively. Note that despite what some people believe, the laser diode in a CD or DVD player is a true laser and not just a glorified LED. It has a gain medium (the semiconductor), mirrors (on the cleaved parallel ends of the crystal), and an means of excitation (electric current). Its nearly monochromatic single spatial mode (TEM00) beam can be focused to a spot less than 2 um in diameter. No LED or other non-laser light source is capable of this kind of performance.
  • A diffraction grating splits the beam into a main beam and two (first order) side beams. (The higher order beams are not used). Note that the diffraction grating is used to generate multiple beams, not for its more common function of splitting up light into its constituent colors. The side beams are used for tracking and straddle the track which is being read. The tracking servo maintains this centering by keeping the amplitude of the two return beams equalized.)
  • Next, the laser beam passes through a polarizing beam splitter (a type of prism or mirror which redirects the return beam to the photodiode array), a collimating lens, a quarter wave plate, a turning mirror, and the objective lens before finally reaching the disc.
  • The collimating lens converts the diverging beam from the laser into a parallel beam.
  • The quarter wave plate converts the linearly polarized beam into a circularly polarized beam. The purpose of this obscure step will become clear below.
  • A turning mirror (optional depending on the specific optical path used) then reflects the laser light up to the objective lens and focus/tracking actuators.
  • The objective lens is similar in many ways to a high quality microscope objective lens. It is mounted on a platform which provides for movement in two directions. The actuators operate similarly to the voice coils in loudspeakers. Fixed permanent magnets provide the magnetic fields which the coils act upon. The focus actuator moves the lens up and down. The tracking actuator moves the coil in and out with respect to the disc center.
  • The collimated laser beams (including the 2 side beams) pass through the objective lens and are focused to diffraction limited spots on the information - pits - layer of the disc (after passing through the 1.2 millimeters of clear polycarbonate plastic which forms the bulk of the disc).
  • The reflected beams retrace the original path back through the quarter wave plate and polarizing beam splitter. However, the reflected circularly polarized beam in passing through the quarter wave plate gets converted back into a linearly polarized beam but at an orientation 90 degrees to the original! So, the polarizing beam splitter is able to divert it to the photodiode array. To repeat in different words: The polarizing beam splitter passes the (horizontally polarized) laser beams straight through. However, two passes (out and back) through the quarter wave plate rotates the polarization of the return beam to be vertical instead and it is reflected by the polarizing beam splitter toward the photodiode array. Sorry, an explaination of why quarter wave plates and polarized laser beams behave this way is somewhat beyond the scope of this document.
The return beams from the disc's information layer are used for servo control of focus and tracking and for data recovery.
  • A cylindrical lens slightly alters the horizontal and vertical focal distances of the resulting spot on the photodiode array. The spot will then be perfectly circular only when the lens is positioned correctly. To close or to far and it will be elliptical (e.g., elongated on the 45 degree axis if too close but on the 135 degree axis if too far). The central part of the photodiode array is divided into 4 equal quadrants labeled A,B,C,D. Focus is perfect when the signal = (A+C)-(B+D) = 0. The actual implementation may use a thick beam splitter mirror (which adds astigmatism) or an astigmatic objective lens rather than a separate cylindrical lens to reduce cost but the effect is the same. Since the objective lens is molded plastic, it costs no more to mold an astigmat (though grinding the original molds may have been a treat!). It is even possible that in some cases, the natural astigmatism of the laser diode itself plays a part in this process.
  • The side beams created by the diffraction grating are positioned forward and back of the main beam straddling the track of pits being followed (not directly on either side as shown in the diagram - but that was easier to draw!). Segments on either side of the photodiode array designated E and F monitor the side beams. Tracking is perfect when the E and F signals are equal.
  • The data signal is the sum of A+B+C+D.
In essence, the optical pickup is an electronically steered and stabilized microscope which is extracting information from tracks 1/20 the width of a human red blood cell while flying along at a linear velocity of 1.2 meters per second! See the sections: "Parts of a CD Player or CDROM Drive" and "Startup Problems" for more information on the components and operation of the optical pickup and descriptions and photos of some typical laser diodes, optical pickups, and optical decks. The Laser Fundamentals Page has an interactive tutorial (requires JAVA) illustrating the operation of an optical pickup in very simplified form. It doesn't really have much detail but if the explanation above makes no sense, it may be worth viewing.

Optical pickup complexity

The opto-mechanical design of optical pickups varies widely. Originally, they were quite complex, bulky, heavy, and finicky with respect to optical alignment. However, in their continuing effort to improve the design, reduce the size and mass, and cut costs, the manufacturers have produced modern pickups with remarkably few distinct parts. This should also result in better performance since each optical surface adds reflections and degrades the the beam quality. Therefore, the required laser power should be reduced and the signal quality should improve.
  • Generally, the most complex types are also the oldest. With these, there were individual optical elements for each stage in the beam path and completely separate laser diode and photodiode array packages. In short, while details varied, the overall construction was very similar to the diagram and description given in the section: CD optical pickup operating principles. These also had several optical adjustments - which in some cases needed frequent attention. An example of this type is the Sony KSS110C Optical Pickup. Most components perform individual functions and it is larger and heavier than more modern designs.
  • The most common types still have a separate laser diode and photodiode array but may have eliminated the cylindrical and collimating lenses and perhaps the polarizer and quarter wave plate. There are few if any adjustments. The Sony KSS361A Optical Pickup is typical of these mainstream designs. With very minor variations (mostly in mounting), various models may be found in all types of CD players and CDROM drives manufactured by Sony, Aiwa, and others. Another similar design is used in the Sanyo K38N Optical Pickup which is somewhat newer and more compact. For a diagram and detailed description of these mainstream pickups, see the section: Sony KSS series optical pickups.
  • Some manufacturers have gone to a combined laser diode/photodiode (LD/PD) array package which looks like a large LD but with 8 to 10 pins. Aside from the objective lens assembly, the only other part may be the turning mirror, and even this is really not needed. Such a pickup can be very light in weight (which is good for fast-access drives) and extremely compact. Eliminating the components needed to separate the outgoing and return beams should result in substantial improvement in optical performance. The only disadvantage would be that the beams are no longer perfectly perpendicular to the disc 'pits' surface and this may result in a very slight, probably negligible reduction in detected signal quality - more than made up for by the increased signal level. The CMKS-81X Optical Pickup and Optical Pickup from Philips PCA80SC CDROM are typical of these modern designs. The smallest ones such as the Optical Pickup from the Philips CR-206 CDROM are only about 1/2" x 5/8" x 3/4" overall - just about the size of the lens cover! For this single-beam pickup, there are absolutely NO additional optical elements inside. A three-beam pickup would have a diffraction grating in front of the laser diode. Some of these use what are known as "hologram lasers" (a designation perhaps coined by Sharp Corporation). With these, the functions previously performed by multiple optical components. can be done by a "Holographic Optical Element" or HOE. The HOE can simply be a diffraction grating replacement or can be designed to perform some more complex beam forming. The typical hologram laser (versions for CD, DVD, and other types of optical storage devices) eliminate the normal diffraction grating in the three-beam pickup as well as the polarizing beam splitter and associated components making for a very simple, compact, low cost unit. DVD Laser Holographic Optical Element shows the HOE glued to the front of a DVD laser diode assembly.  


 For more information on CD technology 

  • A Fundamental Introduction to the Compact Disc Player is a somewhat more theoretical discussion of compact disc audio technology with diagrams and even some equations. If it doesn't put you to sleep, you will find quite a bit of interesting information in this article. In either case, it may prove of value.
  • The University of Washington has at least one course in consumer electronics which varies from year to year. Last year (2000) it was on CD technology but most of that info has disappeared. However, there is an on-line tutorials which appears to be an excellent resource providing easy to understand discussions with many diagrams:
  • The How Stuff Works Web site has some really nice introductory material (with graphics) on a variety of topics relating to technology in the modern world. Of relevance to this document are articles on CD technology, motors, remote controls, power adapters, etc.
  • The following site has a variety of information on CD and DVD technology: A site with CD-R specific information including some repair tips is: An extensive amount of information on other optical disc/k technologies with many useful links can be found at:

    CD Player Placement, Preventive Maintenance, and CD Care

    General CD player placement considerations

    Proper care of a CD player does not require much. Following the recommendations below will assure peak performance and long life, and minimize repairs.
    • Locate the CD player in a cool location. While the CD player is not a significant heat producer, keeping it cool will reduce wear and tear on the internal components and assure a long trouble free life.
    • Don't locate CD players in dusty locations or areas of high (tobacco) smoke or cooking grease vapors. I cannot force you to quit smoking, but it is amazing how much disgusting difficult to remove brown grime is deposited on sensitive electronic equipment in short order from this habit.
    • Make sure all audio connections are tight and secure to minimize intermittent or noisy sound.
    • Finally, store CDs away from heat. The polycarbonate plastic used to mold CDs is quite sturdy but high temperatures will eventually take their toll. Return them to their jewel cases or other protective container when not being played.

    Preventive maintenance

    You no doubt have heard that a CD should be cleaned and checked periodically. "Purchase our extended warranty" says the salesperson "because CD players are very delicate and require periodic alignment". For the most part, this is nonsense. CD players, despite the astonishing precision of the optical pickup are remarkably robust. Optical alignment is virtually never needed for a component CD player and is rarely required even for portable or automotive units. In fact, modern CD players often don't even have any of these adjustments - the components of the optical pickup are aligned at the factory and then fixed in place with hardening sealer.
    An occasional internal inspection and cleaning is not a bad idea but not nearly as important as for a VCR. Realistically, you are not going to do any of this anyway. So, sit back and enjoy the music but be aware of the types of symptoms that would be indications of the need for cleaning or other preventive or corrective maintenance - erratic loading, need to convince the CD player to cooperate and play a disc, audio noise, skipping, sticking, and taking longer than usual to recognize a disc or complete a search. If you follow the instructions in the section: A HREF="#cdgicl">General inspection, cleaning, and lubrication, there is minimal risk to the CD player. However, don't go overboard. If any belts are in good condition (by appearance and stretch test), just clean them or leave them alone. Except for the Sony drawer loading mechanism, belts are rarely as much of a problem in CD players as in VCRs. Of course, acute symptoms like refusal to play or open the door is a sign of the need for emergency treatment. This still may mean that a thorough cleaning is all that is needed.

    CD lens cleaning discs

    Every CD, stereo equipment, department, discount, store - and even sidewalk venders - carries CD lens cleaning discs. Are they of any value? Can they cause damage?
    I generally don't consider CD lens cleaning discs to be of much value for preventive maintenance since they may just move the crud around. However, for pure non-greasy dust (no tobacco smoke and no cooking grease), they may not hurt and could even do a good enough job to put off a proper cleaning for a while longer. However, it's also possible they will ruin the lens. Consider that the worst thing to do to a precision optical surface is to wipe it with a dry cloth as this is likely to scratch the surface as it rubs the dust over it. To the lens, a speck of dust is like a boulder. Once the lens is scratched, replacement of the entire optical pickup is the only remedy. And, since there are absolutely no sorts of standards for these things, it is possible for a really poorly designed cleaning disc to damage the lens even if the dust itself is non-abrasive. In addition, if the cleaning disc doesn't look like a CD to the optical pickup or disc-in sensor, the lens it may not even spin. So, the drawer closes, the drawer opens, and NOTHING has been accomplished! (But at least no damage will be done.) As if this isn't enough, NEVER put one into a high-X CDROM (DVD player or DVDROM drive). The high speed rotation may cause the cleaning disc and/or player/drive to self destruct. And, don't try a cleaning disc on an automotive CD player that sucks in the disk - it will get stuck.

    CD protection and handling

    Although CDs are considerably more tolerant of abuse than LPs, some precautions are still needed to assure long life. Also, despite the fact that only one side is played, serious damage to either side can cause problems during play or render the CD totally useless.
    It is important that the label side of a CD be protected from major scratches which could penetrate to the information layer. Even with the sophisticated error correction used on the CD, damage to this layer, especially if it runs parallel to the tracks, can make the CD unusable. (This differs from a common single-sided DVD where there is a 0.6 mm layer of plastic between the label and the information layer. So, minor damage to the label-side of a DVD will generally not affect playback.) The CD is read by focusing a laser beam through the bottom 1.2 mm of polycarbonate. As a result of the design of the optical system used in the pickup, at the bottom surface, the beam diameter is about 1 mm and thus small scratches appear out of focus and in many cases are ignored and do not cause problems. At the information layer with the pits, the beam diameter has been reduced to under 2 um. Still, scratches running parallel to the tracks are more problematic and can cause the optical pickup to get stuck repeating a track, jumping forward or back a few seconds, or creating noise or other problems on readout. In severe cases, the CD may be unusable especially if the damage is in the directory area. This is why the recommended procedure for cleaning a CD is to use soap and water (no harsh solvents which may damage the polycarbonate or resin overcoat) and clean in a radial direction (center to edge, NOT in the direction of the tracks as you would with an LP). While on the subject of CD care, CDs should always be returned to their original container for storage and not left out on the counter where they may be scratched. However, if there is a need to put one down for a moment, here are some considerations:
    • The label side is probably to be preferred since minor scratches have no effect on performance as long as they do not penetrate to the storage layer below (in which case the CD is probably history). Protectors are available to prevent damage to the label side of the disc. Personally, I think this is taking care to an excessive level but, hey, if you use your CDs as frisbies, go for it!
    • However, the opposite argument may apply as well: Slight damage to the readout-side will be ignored by the optical system or corrected for by the decoding process And, there are ways of dealing with scratches should they occur.
    Thus, I won't offer a hard and fast rule other than to avoid leaving CDs out where the dog can get to them. :) Never apply sticky labels to the readout-side of a disc or to the label-side of a CD unless they are specifically designed for this application. And, if a label was stuck on despite the warnings, don't attempt to remove it (or at least exercise the utmost care) as the lacquer layer and some of your valuable bits may come away with it. This is especially critical for CD-Rs (and maybe CD-RWs) which seem to be more fragile than normal CDs. I've seen samples of CD-Rs literally self destruct due to slight stress on the label side. Once any sort of defect was introduced, it was possible to literally blow the entire information/dye layer off of the disc with low pressure air or water. Remember Bernoulli's prinsciple? :)

    CD cleaning

    You do not need a fancy CD cleaning machine.
    Use a soft cloth, tissue, or paper towel moistened with water and mild detergent if needed. Wipe from center to edge - NOT in a circular motion as recommended for an LP. NEVER use any strong solvents. Even stubborn spots will eventually yield to your persistence. Washing under running water is fine as well. Gently dry with a lint free cloth. Do not rub or use a dry cloth to clean as any dirt particles will result in scratches. Polycarbonate is tough but don't expect it to survive everything. Very fine scratches are not usually a problem, but why press your luck?  

    The method I use for CD/DVD cleaning is to put my pinky finger through the center of the disc holding and turning the edge with my thumb while holding it at an angle (more vertical than horizontal) under running water from a faucet such that the water runs from the center to the edge of the disc (barely missing the pinky). This way, any abrasive dust moves in the direction which does the least damage and the water tends to get under the dust and transport it safely across the disc.
    The disc needs to be dried afterwards. I am usually too impatient to air dry so I wipe with a loosely held wadded up paper towel (the idea is that you do not apply pressure directly from your hand - any pressure is absorbed by the bending of the paper) from center to edge. You can also blot by laying the disc on a couple layers of paper towel. Remove any water that has gotten on the top surface as well, though usually I do not get any water on the top surface using this method. Remember that on CDs, but not DVDs, the top (label surface) of the disc is even more susceptible to damage than the bottom surface (since the data is actually stored just below the printed label). Therefore, use the same care if you clean the label side of the disc and if the disc has abrasive dust on the label side it should be cleaned off. In terms of scratching, wet cleaning is safer than dry. Some computer printed discs may use water soluble ink-jet inks; sometimes a protective finish is applied over top (it may even be ink-jet printed on top). This does not tend to be a problem on commercial discs but if the disc is a low volume (duplicated instead of replicated) or home printed disc, you should be aware that the label might be vulnerable and test for smearing on an unimportant part of the Some. label markers used to write on CD/DVD discs are also water soluble. Some computer printed disk labels can be wet washed without smearing.

    Should I really worry about cleaning my CDs?

    Something that not everyone is aware of is the multilevel error handling technology in a CD player. Therefore, a dirty CD may not produce instantly obvious audio problems but can nonetheless result in less than optimal audio performance.
    Very severe errors - long bursts - will result in audible degradation including noise and/or muting of the sound. Even this may not always be detectable depending on musical context. Shorter runs of errors will result in the player interpolating between what it thinks are good samples. This isn't perfect but will probably not be detected upon casual listening. Errors within the correcting capability of the CIRC code will result in perfect reconstruction. Not all players implement all possible error handling strategies. Therefore, it is quite possible for CD cleaning to result in better sound. However, a CD that is obviously clean will not benefit and excessive cleaning or improper cleaning will introduce fine (or not so fine) scratches which can eventually cause problems.

    Can a dirty CD or dirty lens damage my player?

    So the droid in the CD store warned you that dirty CDs could do irepairable harm to your CD player, your stereo, your disposition, etc. "Buy our $19.95 Super-Laseriffic CD cleaning kit".
    The claim made at one major chain was that dirt or dust on the laser eye would cause heat build-up that would burn out the mechanism. This is different from a dirty disc. The cleaner he was pushing was a little brush attached to a CD that brushed off the lens as it played. This is total rubbish. The power of a CD laser is less than 1 mW and is not concentrated at the lens. And, as noted elsewhere, those cleaning CDs with the little brush are next to useless on anything but the smallest amount of dry dust. There are a lot of suckers out there. Save your money. The worst that can happen is the CD will not play properly. There may be audible noise, it may fail to track properly, abort at random times, or not even be recognized. The electronics will not melt down. It is just about impossible for a dirty CD to do any damage to the player. A dirty lens will only result in disc recognition or play problems similar to those caused by a dirty CD. The laser will not catch fire. The only way damage could occur is if you loaded a cracked CD and the crack caught on the lens. You do not need any fancy CD cleaners in any case - soap or mild detergent and water and a soft cloth are all that are required. If the CD looks clean, it probably will be fine. If there are serious smudges or fingerprints, then cleaning could make a significant difference in performance. For further information, see the sections "CD cleaning" and "General inspection, cleaning, and lubrication".

    Rental or library CD considerations

    Unlike old or worn video tapes, it is unlikely that a 'bad' CD could damage your player. If the borrowed CD is dirty, clean it as described in the section: CD cleaning. If it is badly scratched, the worst that will happen is that it will sound bad - skipping and audible noise. No damage to your player will result. However, if the CD is cracked or broken (this is really difficult to do but I have gotten cracked CDs from public libraries), don't even attempt to load it - a broken edge could catch on the lens and ruin the optical pickup entirely. An improperly made or defective CD could result in seek/search problems which could eventually overheat and/or damage components but you'd probably notice the lack of music before anything irreversible happened.  

    There seems to be a new risk in playing CDs or CD-ROMs borrowed from a public library.
    New, because of the fact that (at least at our library) they have a small metallic strip attached to the top of the CD, apparently as a measure against theft. The strip can be activated/deactivated at the counter, just like the system in use in most department stores. The risk comes from the fact that these strips can come off if you happen to have a CD-ROM player that plays at speeds higher than 40X. There is a warning on the box not to use plates over 40X but who reads the warnings!

    Can a CD player damage CDs?

    The perhaps unexpected answer is a definite *yes* even though everyone has heard about the virtues of non-contact laser playback. There are several ways that a broken or poorly designed or manufactured player can result in scratched discs:
    • If the lens moves too high while attempting to focus and the mechanical stop does not prevent it from hitting the disc, scratches can occur. On some players, the objective lens can easily go this high if focus is not found on the first pass. Note that in most cases, the lens will not suffer since it is protected by a raised ridge which is what actually scratches the disc.
    • Mechanical misalignment of the spindle motor or plastic cabinet parts can result in the disc touching the bottom or top of the disc compartment and this can leave scratches. This could be the result of poor or cheap design, shoddy manufacturing, or damage from a fall or other abuse.
    • If the control logic gets confused, it may allow you to eject a disc while it is still spinning and not fully supported by the spindle platter. A dirty disc that resulted in failure of the CLV servo to lock can result in a disc speed runaway condition with some players. If the drawer is then opened too soon, the disc will still be spinning because the controller has no way of knowing its present status and will not have provided enough reverse torque to stop the spindle motor - or too much and it will be spinning in reverse.
    The likelihood of any of these is increased with dirty, smudged, warped, or previously damaged discs. Minor scratches may not result in a serious problem and there are products to polish them - don't know how well they work. However, if these scratches can be proven to be a direct consequence of a defective player still under warranty, you should try to get some compensation from the manufacturer for any seriously damaged and now unplayable CDs. The one thing that is extremely unlikely is that the laser beam itself is damaging the disc. Although this IS in principle possible IF the disc is stationary AND the laser is on and focussed properly, AND laser power were high enough, at most what would happen is that the information layer would have a microscopic hole blown in it (and this would be taken care of by the error correction processing). However, this really is extremely improbable in a normal CD player or CDROM drive with normal CDs, especially if the unit is working otherwise since the disc starts spinning as soon as focus is established. Forget it. Mechanical causes of damaged discs are about a zillion times more likely! :-) Thus, there is absolutely no way for a software command to the CDROM drive to affect the contents of the disc in any way. The laser power is simply too low to affect the CD and there is no way to boost it, even for an instant. Anything you've heard to the contrary it total rubbish. However, a faulty CD-R or CD-R/W writer could indeed result in damage to CD-R and CD-R/W media from its higher power laser but that's another story.

    Repairing a scratched CD

    So your five year old decided that your favorite CD would make nice frisbee - didn't really know much about aerodynamics, did he?
    Now it sounds like a poor excuse for a 78 rpm record. What to do? There seem to be about as many ways of fixing scratches on CDs as producing them in the first place. However, they fall into 3 classes of techniques:
    1. Mild abrasives: plastic or furniture polish, silver polish, toothpaste. These will totally remove minor scratches. DO NOT use anything that contains solvents including petroleum distillates - if it smells like kerosene, it will likely attack the polycarbonate plastic of the CD rendering it useless. Brasso(tm), a popular product may fall into this category but I've also heard that it works fine without damaging the CD.
    2. Fillers: turtle wax, car wax, furniture wax. Apply over the whole disc and buff out with a lint free cloth. Filling larger scratches should be fairly effective but the disc will be more prone to damage in the future due to the soft wax.
    3. Motorized buffing wheel. Sort of a miniature version of what is used for polishing your car. :) See the details below.
    4. Blowtorch. At least one person who claims to have worked for several years in used CD store swears by this technique. Supposedly, he uses a pencil-type pocket butane torch and with great dexterity fuses the surface layer of the readout side of the disc so that all of those scratches and unsightly blemishes-well-melt away. Obviously, there are dangers in using fire on plastic and this is likely a last resort. I would assume that you are rolling with hysterical laughter at this point. In any case, I would not take this approach too seriously :-).
    For (1) and (2), as with cleaning a CD, when applying or rubbing any of these materials, wipe from the center to the outside edge. A CD player can generally track across scratches that are perpendicular to its path reasonable well, but not those that run the parallel to the tracks. A mild abrasive will actually remove the scratch entirely if it is minor enough. This is probably more effective where the surface has been scuffed or abraded rather than deeply scratched. Wax-like materials will fill in the space where the scratch is if the abrasive was not successful. Even deep scratches may succumb to this approach. A combination of (1) and (2) may be most effective. Commercial versions of these materials are available specifically marketed for repair of CDs. However, the common abrasives and waxes should work about as well. Some are priced exorbitantly for what they contain but I am not familiar with them all. If you'd rather try a commercial CD repair kit, one option is CD Doctor.com. I cannot comment on the use of the blowtorch or how many years of practice is required to get you CD repair license with this technique. However, I am highly skeptical that this works at all and suspect that destruction of the CD is the most likely outcome - totally melting, warping, or cracking or shattering from the thermal stress. In other words, I don't recommend trying the Blowtorch approach unless you have a stack of AOL or MSN CDs to sacrifice and you have sufficient accident insurance! Even some of other solutions may make the problem worse or destroy the CD entirely if not done correctly or if the wrong materials or technique is used. So, test any method on a CD you don't care about first. An alternative to CD home repair are companies specializing in this service. A couple of these are: Aural Tech CD and CD Repairman. I do not have information as to their effectiveness or cost. However, if you have a very special irreplaceable CD that someone used as a skateboard, one of these may be worth considering. (From: Shawn Stopper (shstop@prodigy.net).) In the CD repair process, I use a 1/4 horse electric motor, cotton buff, 2 hose clamps, 2 washers, a screw, and brown tripoli rouge. The motor should be mounted to a surface for permanent use. The first hose clamp should be mounted about halfway back on the motor shaft. A shaft about 4 inches in length will be necessary for this application. after mounting the first hose clamp, apply a washer, the buff, another washer, and the final hose clamp. Mount a screw about 1/2 inch above the motor shaft where the outer clamp can be twisted around the screw to keep the buff spinning. When buffing cds, start out using brown tripoli rouge and slowly move the cd from inside to out. Do not apply too much pressure on the CD because this will cause the CD to "splinter", and it will be ruined. Patience is the key to CD buffing. The first few you do may take longer than you expect, but the more you do the better you get at it. At this time, I can buff about 3 to 4 CDs in five minutes. Once again, practice is the key!

    Repairing top-side problems on CDs

    If scratches penetrate to the information layer, all bets may be off. Much of the optical system compliance with respect to damage depends on the short depth of focus assuring that surface scratches *on the bottom* will be out of focus and ignored. This is not possible with damage to the pits. Even though the CIRC code should be able to deal with thousands of bad bits, such damage can confuse the tracking servos to the point where the disc will be unusable.
    What if the aluminum (or gold) reflective layer has come off with no damage to the plastic underneath? First of all, I don't know how this could occur unless you were attempting to clean them with a strong solvent. Any physical damage which removed the mirror coating will also damage the pits and recoating will be useless. (Note that I have unintentionally removed the gold coating on a CD-R using a solvent similar to what is in Liquid Wrench(tm). I was actually trying to remove the label but went a little too far! The solvent apparently dissolved the greenish coating or binding underneath allowing the gold film and label to just flake off - very strange behavior. Most of the green layer was still intact. I now have a nice greenish somewhat transparent plastic coaster.) Some discs may still work on some players or drives without the aluminum coating. However, this isn't that likely. How to replace it? Ideally, vacuum deposition is needed. The problem isn't only the reflectance but the micro structure - the original coating was vacuum deposited to conform to the pits and lands of the information layer. It is perfectly uniform below the resolution of the laser beam. Modeling (silver or gold colored) paint is amorphous and rough at these feature sizes and floppy disk write protect stickers or other adhesive backed reflective films don't even come close to contacting the information layer consistently. Mirror paint may work but is a long-shot.

    Air purifiers and rubber parts

    Some types of electronic air purifiers may accelerate the deterioration of certain types of rubber materials in electronic equipment as well as household items like carpet pads and door seals. There are also issues with respect to claimed health benefits as well as adverse health effects but that discussion is for a different forum.
    The type of air cleaner that's most likely to be a problem are probably those that supposedly emit negative ions and/or ozone (activated oxygen, O3). These are typically more expensive and some models show up on eBay and in up-scale catalogs.  

    CD Player and CDROM Drive Troubleshooting

    SAFETY

    While there are far fewer potential dangers involved in servicing a CD or DVD player compared to a TV, monitor, or microwave oven, some minimal precautions are still required when working with the cover removed. These relate to electrical connections to the AC line and exposure to the laser beam:
    • Electrical: There may be a few exposed electrically live parts from the power line, usually around the power cord entrance, power transformer, and on/off switch. If there are, tape them over or cover them somehow so you need not be concerned with a low tech shock! Unless you are troubleshooting a primary side power supply problem, there will be no need to go near the AC line.
    • Laser (CD): The laser in a CD player is infra red, near IR - 780 nm - border of visible range but for all intents and purposes invisible. However, it is very low power (generally under 1 mW at the lens) and due to the optics, extremely unlikely that you could be in any danger. Nonetheless, don't go out of your way to look closely into the lens while the unit is on! As long as the lens is intact, the beam is highly divergent and at anything beyond a few inches, especially at an oblique angle, is quite safe. The only possibility of risk would be if the lens fell out and you were looking directly into a collimated beam from above. While the power is less than that of most laser pointers, there would be no aversion reflex to the nearly invisible IR. And, yes, some models of CD players are known to drop their lenses! CAUTION: There is usually a very low intensity (in appearance) emission from an IR laser which appears deep red. It will be visible as a spot the size of the period at the end of this sentence when the lens is viewed from an oblique angle. For a photo of how it actually looks in the dark, see Appearance of IR (780 nm) Laser in CD Pickup (Original photos courtesy of Gag Helfront (ie.dunster@ukonline.co.u).) This is just your eye's response to the near IR energy of the main beam. (Some people apparently cannot see this at all.) Do not be mislead into thinking that the laser is weak as a result of how dim this is. The main beam is up to 10,000 times more intense than it appears! It's power output is generally around 1 mW - comparable to a laser pointer. Take care. However, the red dot is an indication that the laser is being powered and probably functional, though it is no guarantee of the latter. You really need a laser power meter or at least an IR detector to confirm the existence of an IR laser beam. Whenever a full size (5-1/4") CD is in place, there is absolutely no danger of exposure to the laser beam. Reflections of laser light at these power levels are harmless. However, if you are testing with a 3-1/2" 'single' or homemade cut-down test CD (see the section: Useful ways to mangle CDs, avoid staring into the lens if there is any chance the laser is powered. If you don't want to take even the minimal risk of looking into the lens at all, project the beam onto a piece of paper held close to the lens. In a dark room, it should be possible to detect a red spot on the paper when the laser is powered.
    • Laser (DVD): The DVD laser pickup is very similar to that of the CD player except that the wavelength is in the 635 to 650 nm range which is a very visible red - about the same as the color of newer laser pointers or a helium-neon laser (632.6 nm). The power is still under 1 mW and everything else above is still applicable. One note: If the DVD player is of the dual pickup variety with a separate laser for CDs, that one is IR like a normal CD player and the precautions listed above will apply. Take care because it may not be obvious ahead of time which one (or if both) will be powered!
    • Laser (CD-R, CD-RW, DVD-R, DVD-RW, and other writeable optical drives): These may use laser diodes producing 10s to 100s of mW. A typical CD-R drive sets the laser power at 3 to 5 mW for read and 25 to 30 mW for write. A high performance DVD-R drive may produce 200 mW *or more* for writing. While the basic precautions are the same, much greater care must be taken due to the much higher power when writing. Although it's unlikely for the write laser power to come on while doing most troubleshooting, a fault could allow this to happen so these drives should be treated with respect.

    Troubleshooting tips

    Many problems have simple solutions. Don't immediately assume that your problem is some combination of esoteric complex convoluted failures. For a CD player, it may just be a bad belt or dirty lens. Try to remember that the problems with the most catastrophic impact on operation (a CD player that will not play past track 6) usually have the simplest solutions (the gears that move the optical pickup need lubrication). The kinds of problems that we would like to avoid at all costs are the ones that are intermittent or difficult to reproduce: the occasional audio noise or skipping or a CD player that refuses to play classical CDs (depending on your tastes!) of music composed between the years 1840 and 1910.
    When attempting to diagnose problems with a CDROM drive, start by trying to get it to play an audio CD. Data readback is more critical since the error correction needs to be perfect. However, with audio playback functional, all of the optical pickup and most of the servo systems and front-end electronics must be working. A CDROM drive which cannot even play a music CD will have no chance of loading Windows 95. If you get stuck, sleep on it. Sometimes, just letting the problem bounce around in your head will lead to a different more successful approach or solution. Don't work when you are really tired - it is both dangerous and mostly non-productive (or possibly destructive). Whenever working on precision equipment, make copious notes and diagrams. You will be eternally grateful when the time comes to reassemble the unit. Most connectors are keyed against incorrect insertion or interchange of cables, but not always. Apparently identical screws may be of differing lengths or have slightly different thread types. Little parts may fit in more than one place or orientation. Etc. Etc. Pill bottles, film canisters, and plastic ice cube trays come in handy for sorting and storing screws and other small parts after disassembly. Select a work area which is well lighted and where dropped parts can be located - not on a deep pile shag rug. Something like a large plastic tray with a slight lip may come in handy as it prevents small parts from rolling off of the work table. The best location will also be relatively dust free and allow you to suspend your troubleshooting to eat or sleep or think without having to pile everything into a cardboard box for storage. Another consideration is ESD - Electro-Static Discharge. The electronic components - especially the laser diode - in CD players, CDROM drives, and similar devices, are vulnerable to ESD. There is no need to go overboard but do take reasonable precautions like not wearing clothing made of wool that tends to generate static. When working on component CD and laserdisc players, get into the habit of touching a ground like the metal chassis before touching any circuit components. The use of an antistatic wrist strap would be further insurance especially if the optical pickup assembly needs to be unplugged for any reason. A basic set of precision hand tools will be all you need to disassemble a CD player and perform most adjustments. However, these do not need to be expensive. Needed tools include a selection of Philips and straight blade screwdrivers, needlenose pliers, wire cutters, tweezers, and dental picks. A jeweler's screwdriver set is a must particularly if you are working on a portable CD player or CDROM drive. For making servo adjustments, non-metallic fine tip jeweler's screwdrivers or alignment tools will be essential as some of the front-end circuitry may be sensitive to body capacitance - contact with the slot may alter the behavior of the player (for better or for worse). In a pinch, wrapping electrical tape around the part of a normal jeweler's that you grasp will probably provide enough isolation. However, with a tool with a blade made out of an insulator, you will be less likely to accidentally short things out as well Note that low level signals from the optical pickup like the data (RF) and other photodiode outputs are extremely sensitive to interference picked up from a finger on or near the flex cable, a disconnected ground strap, or possibly even a nearby broadcast antenna. Thus, when the optical deck isn't fully mounted and connected, there may be unusual behavior - this is probably normal. Just be aware of this and don't panic, and adjustments should be made with the unit as close to fully assembled as possible. You should not need any CD specific tools except in the unlikely event you get into optical alignment in which case the service manual will detail what tools and special rigs are needed. A low power fine tip soldering iron and fine rosin core solder will be needed if you should need to disconnect any soldered wires (on purpose or by accident) or replace soldered components. CAUTION: You can easily turn a simple repair (e.g., bad solder connections) into an expensive mess if you use inappropriate soldering equipment and/or lack the soldering skills to go along with it. If in doubt, find someone else to do the soldering or at least practice, practice, practice, soldering and desoldering on a junk circuit board first! See the document: Troubleshooting and Repair of Consumer Electronic Equipment for additional info on soldering and rework techniques. For thermal or warmup problems, a can of 'cold spray' or 'circuit chiller' (they are the same) and a heat gun or blow dryer come in handy to identify components whose characteristics may be drifting with temperature. Using the extension tube of the spray can or making a cardboard nozzle for the heat gun can provide very precise control of which components you are affecting. Basic cleaning supplies include Q-tips (you may know them as cotton buds), lint free cloths or paper towels, water, and isopropyl alcohol (preferably 91 percent medicinal grade or better). Note that isopropyl alcohol also goes by the names isopropanol, 2-propanol, and propan-2-ol. They are all the same thing. For info on useful chemicals, adhesives, and lubricants, see Troubleshooting and Repair of Consumer Electronic Equipment as well as other documents available at this site.

    Test equipment

    Don't start with the electronic test equipment, start with some analytical thinking. Many problems associated with consumer electronic equipment do not require a schematic (though one may be useful). The majority of problems with CD are mechanical and can be dealt with using nothing more than a good set of precision hand tools; some alcohol, degreaser, contact cleaner, light oil and grease; and your powers of observation (and a little experience). Your built in senses and that stuff between your ears represents the most important test equipment you have.
    A DMM or VOM is necessary for checking of power supply voltages and testing of sensors, LEDs, switches, and other small components. This does not need to be expensive but since you will be depending on its readings, reliability is important. Even a relatively inexpensive DMM from Radio Shack will be fine for most repair work. For servo and other electronic problems, an oscilloscope will be useful. However, it does not need to be fancy. A 10 to 20 MHz dual trace scope with a set of 10X probes will be more than adequate for all but the most esoteric troubleshooting of CD players and CDROM drives. To determine if the laser diode is working properly, a laser power meter is very useful. Such a device is expensive but is often essential to properly and safely adjust laser power on many CD players and CDROM drives. However, for many problems, simply knowing that an IR laser beam is being emitted is enough. For this, the simple device described in the section: IR detector circuit is more than adequate. Alternatively, an inexpensive IR detector card or even some camcorders can perform the same function. A stereo amplifier and loudspeakers is essential to allow your most important piece of audio test equipment to function effectively - your ears. A lot can be determined by listening to the audio output to distinguish among dirt, lubrication, servo, control, and other mechanical or electronic problems. I would caution against the use of headphones as a sudden burst of noise could blow your eardrums and spoil your entire day. For testing of optical pickups, some additional equipment will be needed. However, this will be detailed in the section: Testing of Optical Pickup Assemblies.

    Test CDs

    An inexpensive test CD is nice to have just to be able to play known frequencies and volume levels. However, it is not essential - any half decent CD will work just fine for most tests. For many players, even an old CDROM disc will be adequate to diagnose startup problems. However, to fully exercise the limits of the player, a disc with a full 74 minutes of music will be needed - Beethoven's Ninth Symphony is a good choice (even if you are not into classical music) since it is usually very close (or sometimes slightly over) this length of time.
    Keep those old demo CDs or even obsolete CDROM discs - they can be used for testing purposes. Where an optical deck has a servo problem, the disc will end up spinning out of control. Stopping this suddenly may result is the CD scraping itself against the drawer or or base of the deck and getting scratched. Therefore, some 'garbage' discs are always handy for testing purposes. To evaluate tracking and error correction performance, any CD can be turned into a test CD with multiple width strips of black tape, a felt tip marker, or even a hand drill! In fact, some professional test discs are made in exactly this manner. Also see the sections: "Comments on test discs" and "Custom test CDs using CD-Rs".

    Useful ways to mangle CDs

    These suggestions will allow you to put some of those AOL CDs to good use (well, besides making high tech coasters)!
    • For portable CD players where the designers in their infinite wisdom put some of the servo adjustments *under* the spinning disc, a 3-1/2" CD 'single' is extremely handy. A normal CD can be cut down as well - to whatever size you need as long as enough actual tracks are left so that the directory and a few minutes of music/data remain - this could be as little as about 2-1/2" to gain access to the adjustments on some models. This surgery is best done on a band saw with a narrow fine tooth blade. However, tiny cracks may grow in from the edge (overnight, even) if the disc is subjected to any heating or stress from cutting or smoothing. Perhaps some annealing is needed to prevent these from getting started. Note that the lower mass (actually the lower moment of inertia for you purists) of the small CDs may alter the servo response somewhat. Putting a heavy metal ring or washer on top should help. However, this is still much much better than continually having to remove a normal CD to get at the adjustments, incrementally moving them one way or another, and then replacing the CD to see how you made out. One can grow old doing this! The little CDs will enable you to monitor the test points as the adjustments are made which is also a definite advantage :-). The RCA RP-7903A Portable CD Player is an example of a design where this type of modified CD is invaluable for testing.
    • A handy special miniature CD can be made to permit viewing of the focusing action on any CD player or CDROM drive as long as you can get to the top of the deck while testing. Using a band saw, cut a garbage disc down so as to leave only a 1-1/2" diameter center hub with a 1/2" by 1/2" tab sticking out from it. This can then be positioned by hand to just cover the lens while it is supposed to be doing its focus search.
    • An alternative that will permit you to view both the laser output (from a safe distance) and the focusing action is to create a window in a garbage CD by removing the label and aluminum layers from an area of the CD at the inner tracks - at least a square inch worth. Lacquer thinner (nail polish remover, with adequate ventilation) will probably work to remove the label. Fine sand paper or steel wool will remove the aluminum and information pits/lands (grooves). Then polish with a buffing wheel or old rag.
    CAUTION: when using any of these cut-down or windowed test CDs, or 3-1/2" 'singles', avoid staring into the lens when the laser is powered. See the section: SAFETY.

    Getting inside a CD player or CDROM drive

    WARNING: you will void the warranty, if any. You may make the problem worse, possibly much worse. If the player partially worked, it may no longer even recognize the disc directory. You may accidentally damage parts that were perfectly fine. If you should decide to then have the unit professionally serviced, you may find that the shop simply refuses to touch it if they suspect your tampering. There is nothing worse than having to undo 'fixes' introduced by a well intentioned do-it-yourselfer where the state of the player is now a total unknown. At best you will be charged for this effort on a time and materials basis. It may be very costly. It may not be worth the expense.
    A CD player still under warranty should probably be returned for service for any covered problems except those with the most obvious and easy solutions. On the other hand, it is possible that you will do a better job than some repair shops. You will probably have a better understanding of the basic theory and will certainly be able to spend much more time on the problem. And, of course, hobbiest/handyman's time is cheap - as in free.
    • Component CD players. It is generally very easy to remove the top cover on most CD players. There are usually some very obvious screws on the sides and possibly back as well. These are nearly always Philips head type - use the proper screwdriver. Once all the screws are out, the top cover will lift up or slide back and then come off easily. If it still does not want to budge, recheck for screws you may have missed. Once the top cover is removed, the optical deck and electronics board will usually be readily accessible. In rare cases, removing the bottom cover will provide access to the solder side of the electronics board. However, with most CD players, the bottom is solid sheet metal and the entire board would need to be unmounted. On some, the electronics board is mounted upside-down so there is full access to the wiring side once the cover is removed.
    • With most single play designs, the entire optical deck can be lifted out after removing 3 or 4 screws. One screw may have a grounding contact under it. Replace this in exactly the same position. There may be fragile flexible cables. Be careful so as not to damage any. Usually, these cables plug in to connectors on the electronics board and permit the entire optical deck to be easily replaced if needed (not very common, however, despite what you may have heard).
    • For changers, details will depend on the particular model but in general, it is more likely that removal of the entire changer mechanism will be more involved. However, this is usually not needed unless there is an actual mechanical problem with it. With Pioneer cartridge changers, for example, the optical deck is easily removed with just 4 screws.
    • For portables, the bottom plate or top cover usually comes off after removing several very tiny screws - use the proper size Philips blade jeweler's screwdriver and don't lose them. Then, you either have access to the bottom of the mainboard or the top of the mainboard blocked mostly by the optical deck. With the RCA RP-7903A Portable CD Player, it is the latter and the pickup and/or normal size CD conveniently block all access to servo adjustments and test points (which as is often the case, are ummarked in this RCA unit). These types of CD players are usually quite a pain to troubleshoot! Of course, there are also many components including most of the large multilegged ICs surface mounted on the *bottom* side of the mainboard which makes for even more fun should probing be required! You can easily see all the 'stuff' packed into a box just slightly larger than a CD!
    • For CDROM drives, both top and bottom covers may be removable depending on model. These are more wide open than portables, especially the newer models where everything has been shrunk to a tiny optical pickup and circuit board with a few large ICs. Unfortunately, adjustments (if any) and test points are even less likely to be labeled on CDROM drives. All testing will also require a working PC unless your model has built-in audio play capability.
    Make notes of screw location and type and immediately store the screws away in a pill bottle, film canister, or ice cube tray. When reassembling the equipment make sure to route cables and other wiring such that they will not get pinched or snagged and possibly broken, or have their insulation nicked or pierced, and that they will not get caught in moving parts. Replace any cable ties that were cut or removed during disassembly and add additional ones of your own if needed. Some electrical tape may sometimes come in handy to provide insulation insurance as well. (This applies mostly to portables and CDROM drives - component CD players are very wide open.

    CD enhancers

    The process of reading a CD is digital. I have seen and heard advertisements for sonic rings or special magic markers to improve the quality of the digital audio reproduction. This is total bunk. Don't waste your money. These products do nothing beyond depleting your pocketbook - and enhancing those of the vendors.
    For more amusement, see the section: Totally worthless gadgets for CD enthusiasts. Along the same lines, some apparently knowledgeable people (knowledgeable in what you might ask!) have asked if offers of software to turn a CDROM drive into a CD-R writer should be believed! This is just utter and total nonsense and what's more likely to happen if you fall for such a SCAM is to become the new owner of some nasty computer virus! Besides, this must be impossible since there is no place for a red "write" LED on a CDROM drive! :)

    What about DVD player and DVDROM drive servicing?

    DVD players and DVDROM drives have hit the market place in a big way and (if you believe the hype), DVDs are about to replace CDs totally. Realistically, this won't happen for some time. In any case, DVD players and DVDROM drives are *supposed* to accept CDs, CD-Rs, and CD-RWs, so no need to panic just yet. But availability of new CD based devices will disappear because the cost to manufacture a DVD player or drive isn't much more than that of a similar CD unit so manufacturers will want to close down their old production lines and concentrate on DVDs only.
    In any case, eventually all things break, and DVD equipment will be no exception. Fortunately for us, the similarities between CD and DVD technology are much more significant than the differences. The inside of a DVD player looks pretty much the same as the inside of a CD player and, for the most part, the same problems are likely to occur. Here are some things to look out for:
    • DVD discs look virtually identical to CDs. They are the same size and thickness with the same large center hole and will fit perfectly well into a CD player or CDROM drive - but of course won't do much there. Despite the tracks and pits being closer together, the rainbow/diffraction effects are about the same so a casual glance isn't enough to tell them apart but there is always that DVD logo! However, the information layer is precisely in the center of a sandwich of polycarbonate (each half 0.6 mm thick). (The DVD standard supports a double sided DVD. This, of course leaves virtually no room for the label!) More info on DVD media, storage capacity, and so forth can be found in the section: Comparison of CD and DVD Specifications.
    • The laser in a DVD based device is a very visible red (a wavelength around 650 nm compared to the nearly invisible IR 780 nm laser used for CDs). This is about the same wavelength as used in newer red laser pointers. It is still low power (1 mW or less at the objective lens) but the laser will appear very bright when it is powered and working correctly. As far as hazards to vision, the same recommendations apply - don't look into the beam directly but viewing from an oblique angle at 12 inches or more from the objective lens should be safe. The eye's aversion reflex will prevent damage in any case - you will blink or turn away from a the bright light. CAUTION: Some (probably older) DVD equipment may also have a standard CD pickup to be able to read CDs. For these, obviously, all the IR laser precautions apply.
    • It should be easier to determine if the laser is bad by brightness alone though a laser power meter and the manufacturer specifications will still be needed in marginal cases.
    • As a result of the march of technology, the optical pickup is likely to of simpler design than that in older CD based devices with even fewer or no adjustments possible. However, there could be additional complexity due to the need to handle DVDs and CDs in the same equipment. The use of combined laser diodes and photodetector arrays is likely to be quite common if not pervasive. However, pickups may also use separate laser diodes and photodiode arrays possibly sharing some of the optics or at least part of the beam path in the optical block. In some pickups, objective lenses for the CD and DVD lasers can be rotated into position as required by applying enough current of the appropriate polarity to the fine tracking coils..
    • The same basic functions need to be performed by the front-end electronics including amplification of the photodetector array output, and focus, tracking, and spindle servos. Much this is likely to be done inside large chips with no service adjustments.
    • More functions will be incorporated into fewer surface mount chips. Fortunately, failures of the large scale integrated circuits themselves are not nearly as common as simple mechanical problems. Better hope so in any case as troubleshooting of things like an MPEG decoder is way beyond what could be done without a complete service manual, sophisticated test equipment, and probably a whole lot more!
    • More plastic and less metal is likely to be used - lighter, flimsier, less likely to be serviceable at all.
    So, the bad news is that if something breaks inside a large chip, accept defeat and send the unit in for service. The good news is that most problems will still be mechanical - dirt, dust, gummed up grease, bad motors, abuse. From our experience with CD repair, we should be well equipped to deal with these! Hopefully, manufacturers have learned from their experience with CDs to make a more reliable robust product but that may be wishful thinking where the bottom line is involved. It's still too early to tell. 

    CD Player and CDROM Drive Fundamentals

    Parts of a CD player or CDROM drive

    While CD players and CDROM drives started out and still have much in common, they are diverging. The optical pickups remain similar but the data processing and servo systems needed to support 16X speed CDROM technology are much more sophisticated than those needed for 1X speed CD audio. Therefore, should you peek inside your shiny new CDROM drive, you may see parts that differ considerably from those in a old Discman.

    Power supply

    In component stereos units, there are normally linear supplies and thus very reliable but easy to repair as well. In portables, they are likely to be switching supplies, possibly sealed in a shielded can (or at least all surface mount components), and difficult to troubleshoot and repair.
    Usually, at least three voltages are needed: logic power (e.g. +5 Vcc) and a pair of voltages for the analog circuitry (e.g., +/- 15V). However, some designs use a variety of voltages for various portions of the analog (mainly) circuitry.

    Electronics board

    This contains the microcomputer controller, servos, readback electronics, audio D/A(s) and filters. Most servo adjustment pots will be located here. In many cases they are clearly marked but not always. DO NOT turn anything unless you are sure of what you are doing - and then only after marking their original positions precisely.

    The optical deck

    This subsystem includes all of the components to load and spin the disc, the optical pickup, and its positioning mechanism. Refer to the section: Typical optical decks for photos of some common models.
    • Loading drawer - Most portable and many lower cost CD players or CDROM drives lack this convenience. Most are motor driven. However, some must be pushed in or pulled out by hand. Common problems: loose or oily belt causing drawer to not open or close, or to not complete its close cycle. There can be mechanical damage such as worn/fractured gears or broken parts. The drawer switch may be dirty causing the drawer to decide on its own to close. The motor may be shorted, have shorted or open windings, or have a dry or worn bearing.
    • Spindle, spindle table, or spindle platter, (we will use these names more or less interchangeably) - When the disc is loaded, it rests on this platform which is machined to automatically center it and minimize runout and wobble. Common problems: Dirt on table surface, bent spindle, dry or worn bearings if spindle not part of motor but is belt driven, loose spindle.
    • Spindle motor - The motor that spins the disc. Most often the spindle platform is a press fit onto the spindle motor. Two types are common: The first is a miniature DC motor (using brushes) very similar to the common motors in toys and other battery operated devices. The second type is a brushless DC motor using Hall effect devices for commutation. If there are more than 2 wires attached to the motor or if it uses exposed coils and control board, it is likely of the brushless type. In very rare cases, a belt is used to couple the motor to the spindle but most are direct drive - the spindle is the motor shaft. Common problems: partially shorted motor, shorted or open winding, dry/worn bearings, defective electronics. The brushless type are much less likely to have electrical problems.
    • Clamper - Usually a magnet on the opposite side of the disc from the spindle motor which prevents slippage between the disc and the spindle platform. The clamper is lifted off of the disc when the lid or drawer is opened. Alternatively, the spindle may be lowered to free the disc. Common problems: doesn't engage fully permitting disc to slip on spindle due to mechanical problem in drawer closing mechanism.
    • Sled - The mechanism on which the optical pickup is mounted. The sled provides the means by which the optical pickup can be moved across the disc during normal play or to locate a specific track or piece of data. The sled is supported on guide rails and is moved by either a worm or ball gear, a rack and pinion gear, linear motor, or rotary positioner similar to what is in a modern hard disk drive - in increasing order of performance. Note that a single-beam optical pickup can be used with either a linear or rotary mechanism. However, a three-beam pickup will not work with a rotary positioner because the angle of the pickup changes with radial position. Functionally, neither type is fundamentally superior but most manufacturers seem to use the three-beam type. Philips/Magnavox (and their other brand names) appear to be the principal exceptions. Common problems: dirt, gummed up or lack of lubrication, damaged gears.
    • Pickup/sled motor - The entire pickup moves on the sled during normal play or for rapid access to musical selections or CDROM data. The motor is either a conventional miniature permanent magnet DC motor with belt or gear with worm, ball, or rack and pinion mechanism, or a direct drive linear motor or rotary positioner with no gears or belts. Common problems: partially shorted motor, shorted or open winding, dry or worn bearings.
    • Optical pickup - This unit is the 'stylus' that reads the optical information encoded on the disc. It includes the laser diode, associated optics, focus and tracking actuators, and photodiode array. The optical pickup is mounted on the sled and connects to the servo and readback electronics using flexible printed wiring cables. Common problems: hairline cracks in conductors of flexible cable causing intermittent behavior.

    Typical optical decks

    Some examples of common optical decks and optical blocks (just the pickup assemly) are shown in the following sets of photos. The disc loading components and clampers are not shown. Note: The resolution of the optical deck photos is 37.5 dpi unless otherwise noted. All other photos include a scale indicator.
    The first 4 are from consumer grade CD players:
    • The Pioneer CD Player Optical Deck shows a typical sled-type using a PM motor driven screw. This uses a three beam pickup. This model (or one similar to it) can be found in both Pioneer single (e.g., PD5100) and changer (e.g., PDM500) type CD players. In the latter case, the assembly is mounted upside-down with the clamper on the bottom.
    • The Sony D-2 CD Player Optical Deck shows another common sled-type with a gear driven rack. This model (and as far as I know, all others from Sony) use three-beam pickups. This deck (or one similar to it) can be found in the Sony Model D2 and other portable CD players. (The flex cable, a common failure item, has been removed to provide unobstructed views.) It uses the Sony KSS220A optical pickup which is virtually identical to the Sony KSS361A Optical Pickup.
    • The Sony D-14 CD Player Optical Deck is also uses a gear driven rack. It has a three-beam pickup. This deck is from a very old D-14 portable CD player, possibly only the second portable model manufactured by Sony. The Sony KSS110C Optical Pickup it uses is distinctly different than other more modern Sony models. In addition to being larger, the optics include a beam splitter prism, a negative lens in the return path, and the objective lens is mounted on a shaft enabling it to slide up and down (for focus), and rotate (for tracking).
    • The Philips CD Player Optical Deck provides an example of a unit using a rotary type voice coil tracking actuator and uses a single-beam pickup. This one came from a front loading (flip down see-through door) Magnavox Model AH197M37 Modular Stereo System (includes dual cassette, AM/FM radio, and turntable). CD players and some CDROM drives manufactured by Philips (this includes the Magnavox and Sylvania brand names) seem to be the only ones still using rotary actuator technology in consumer products. In older versions, parts of the optical pickup (like the laser diode) were pluggable and easily replaced.
    The three below are from CDROM drives:
    • The Sony CDU-31/33A CDROM Optical Deck is typical of the mechanism found in lower performance models that use a screw drive for sled positioning. The pickup used is a three-beam KSS360A which is very nearly identical to the Sony KSS361A Optical Pickup (only the shape of the mounting bracket differs). Like its consumer CD player counterpart, everything is glued in place at the time of manufacture - there are no adjustments. The CDU-31A 1X, CDU-33A 2X, and other CDROM drives using this deck were probably the most popular models in the early 1990s. The CDU-31/33A used the Sony proprietary interface (also available on some sound cards) and were certainly nothing to write home about in the speed department. These drives used a high quality brushless DC motor for the spindle while other similar performance CDROM drives of the era had cheap permanent magnet DC motors that were prone to failure. However, they were the only popular front loading CDROM drives to NOT have the convenience of a motorized drawer mechanism - just a solenoid release. Of course, there was less to break down!
    • The Sony CDU-8001 CDROM Optical Deck provides an example of a unit using a direct drive linear motor for the coarse tracking actuator. The pickup is a three-beam Sony KSS180A - quite similar to the Sony KSS361A Optical Pickup but appears to be more solidly constructed with at least one additional optical element that may be a collimating lens. Unlike most consumer grade pickups, the KSS180A is not totally glued together and some adjustment of optical alignment is possible. This deck came from a Sony CDU-8001 CDROM Drive Unit - a speedy 1X drive (aren't you impressed?) used with a SCSI interface for an Apple MacIntosh computer. The NEC Model CDR-82 CDROM Reader and others of the same vintage also use the same Sony KSS180A pickup. These were of the cartridge loading type (loading mechanism removed). The spindle motor is a high quality DC brushless type. Some component CD players by Technics (Matsushita) and others (in addition to Sony) also used linear motor technology as early as 1983 (possibly even before) to provide fast (under 1/2 second) music seek times which is better performance than some of the early CDROM drives using screw or gear type actuators.
    • The Philips CR-206 CDROM Optical Deck views provide an example of a drive using a rotary actuator for both coarse and fine tracking. This uses a single-beam pickup where the laser diode and photodiode are combined into one package which is mounted in a very simple compact optical assembly. This deck came from an inexpensive Philips CR-206 2X CDROM drive (vintage 1994). Note how much smaller this assembly is compared to the Philips CD player optical deck, above, which dates from around 1990.
    Interestingly, most common popular higher performance CDROM drives (e.g., 4X, 12X, even 16X or more) do not use linear motors or rotary positioners to achieve rapid seek times. They use a screw or gear drive powered by a cheap permanent magnet DC motor! However, they do all use high quality brushless DC motors for the spindle since these high-X drives put a lot of stress on this component (especially those which are the true CLV type and vary speed based on track location). Although the optical pickups themselves have been simplified and have reduced mass, and the drive mechanism had been speeded up compared to the typical cheap portable CD player, this type of implementation is still far from optimal. Therefore, while the transfer rate may be pretty good (see the section: CDROM drive speed - where will it end? for why this really isn't assured even with a 32X unit), seek times may be mediocre - 250 ms full stroke being typical. The next two are nearly complete CDROM drives of this type:
    • The Philips PCA80SC CDROM Drive Optical Deck is a relatively modern design typical of low cost high spin-rate units. This one is an 8X model. The Optical Pickup from Philips PCA80SC CDROM appears to be a three-beam type. Apparently, many manufacturers used this basic mechanism. I have an Aztech CDA-268-01A CDROM drive (2X) which has the same pickup and a very similar optical deck.
    • The Teac CD-532S CDROM Drive is another popular design used in late model (1998) low cost high spin-rate units. This one is a 32X (Max) model with a SCSI interface. The 32X (Max) rating really means that it spins at constant speed roughly equivalent to a 13X rate and the 32X spec is only achieved for data located near the outer edge of the disc. The Sony KSS575B three-beam pickup used in this drive is quite compact but of the more complex design using a separate laser diode and photodiode array with beam splitter. The optical path is equivalent to that of that of the Sony KSS361A Optical Pickup. (See the section: Sony KSS series optical pickups.) The guts are located in a central box-like object about 1.5 cm on a side. However, the pickup is mostly made of plastic - gone are the days of the cast metal optical block! While this does make it weigh less, the difference would hardly seem to be significant for access speed given the primitive screw drive. The Sanyo K38N Optical Pickup used in the earlier (like all of 3 months!) Teac model, the 16X CD516s, is substantially similar to this but of more solid construction. Teac CDROM drives from 6X (and possibly below) through this 32X unit appear virtually identical mechanically. Also notice how little electronics there is in this unit - nearly all the circuitry is on the single small circuit board on the left side of the bottom view. On all the other CDROM drives, the logic board occupied all the space (and more in some models) above or below the optical deck! 
  • The Toshiba SD-M1212 DVDROM Drive is typical of the DVDROM drives shipped with bundled PCs (I believe this was from a Dell Dimension 450 MHz Pentium II system). The most notable feature of the optical deck used here is that it really is so similar in appearance to those used with late model CD players or CDROM drives. In fact, without the DVD logo or other distinguishing markings, it could just as well have been a CDROM drive. (Of course, we know that what's inside is quite different at least in the details.) I wasn't willing to go any deeper since this is still a working unit so there could be internal differences. An update will be forthcoming when I get my hands on a broken one! Note that it appears to have only a single objective lens. This would tend to imply that compromises have been made, most likely for CDs, and that performance with them may not be as good as with a dedicated CDROM drive. One thing that is obvious is the amount of circuitry compared to say, the Teac CD532s, above, whose PCB occupied less than 1/3rd of the available area. I don't know how much this is due to just being newer technology which hasn't been as highly integrated yet as opposed to the additional complexity required for DVD decoding and support for CD audio and data formats as well.
  • The Optical Path of CD/DVDROM from Sony F390 Laptop shows the optics and laser diode assemblies from below. The objective lens would be where the turning mirror faces. This unit has separate DVD and CD lasers, each of the "hologram laser" type with a Holographic Optical Element (HOE) for generating the side beams and replacing the polarizing beam splitter and other components. One of the laser diodes is a Sharp HPD 24T3 according to the markings. The DVD laser diode assembly has a 3 way beam splitter crystal on the front, 'T' shaped, and the other has a two way splitter '-' on the crystal face. DVD Laser Holographic Optical Element shows the HOE on the DVD laser diode assembly. Thanks to John LeBourgeois (john@121email.com) for these photos. (The resolution of these photos is not known.)
  • The resolution of the following optical block photos is 150 dpi unless otherwise noted.
    • CD/DVD Dual Lens Optical Block 1 is the optical assembly from an (manufacturer unknown) CD and DVD reader, possibly from a Toshiba laptop (though it seems HUGE for that!). The interesting thing about this unit is separate lenses for the CD and DVD. By applying appropriate drive to the tracking coils, the appropriate lens is rotated into position.
    • CDRW/DVD Optical Block 1 is from a CD writer which apparently had buggy software. The two laser diodes can be seen in the lower left corner of the bottom photo (bottom view). The LD feeding the beam-splitter cube in the center is high power and for the CD (both read and write). Below and to the right of the cube appears to be a sensor, possibly to control the power of that diode for read and write, since it has no internal monitor photodiode.
    • KHS-400B CD/DVD Optical Block is for a PS2 and is of about the most minimal complexity possible. The top views are with and without the lens cover. The LDs for both CD and DVD readout and PD array are all in a single package just visible at the right end of the assembly in the top two photos. A closeup of its interior is shown in KHS-400B CD/DVD Combined LDs/PDs. The LDs are on the left and the PD array is on the right. The blue block is probably the hologram diffraction grating for the three-beam tracking system. The only external optical components besides the turning mirror and objective lens, is a slightly angled plate, function unknown. Interestingly, some sellers offer just the surface mount package as a replacement for the KHS-400B optical block - and at a higher price than for the entire new KHS-400B from others! I can't imagine trying to replace only the SMT LD/PD package. Not only does that require removal of the old one, fine soldering, gluing to the metal bracket which implements a mini-spherical adjustable mount, following by optical alignment. Sounds like torture to me. :)
    • Sony PVR-802W CD/DVD Optical Block (pvr802w1.jpg) is called a PS2 "slim-line". (This is apparently similar to a KHM-430 and KHS-430.) Is also quite simple, but still uses separate laser diode and photodiode arrays. Both laser diodes (red and IR) are in a single 5.6 mm can with a Brewster-angle window. Beyond the LDs and PD array, there are only 5 other optical parts!
    • Panasonic UJ8D1 CD/DVD RW Optical Block. This is a modern (2013) combined CD/DVD pickup from a "SATA Super Multi 8X DVD-R Double Layer DVD RW Recorder 24X CD-R Burner for Laptops". What's interesting about this is how ordinary it appears, using an optical layout that is similar to pickups that are 10 or 15 years older. Being designed for use in a laptop, it is only around 5 mm thick, but not that small in its other dimensions. The only difference in the top two photos is the removal of the metal cover. All the electronics are interconnected by a single kapton ribbon cable. So to avoid being totally destructive, the components attached to it were also pulled off, except for the laser diode assembly, which had its own short ribbon cable soldered to the main one. The bottom left view shows what remains: Most of the optics and the case with the laser diodes at the bottom with its short ribbon cables. The ribbon cable with all its attachments is at the right. Below the objective lens assembly are clockwise, the LD driver IC, laser power monitor IC, and photodiode array IC. This is a fairly typical three-beam optical pickup. However, since it's for a burner, the laser diodes are relatively high power. And they don't have internal monitor photodiodes. Rather the otherwise wasted beam through the beam-splitter hits a power monitor assembly which is used for this purpose. For the overall organization, see Optical Paths of Panasonic UJ8D1 CD/DVD RW Drive. The annotated inset photo at the lower right shows the optics portion of the pickup along with a 1 cm scale for reference. However, the diagram itself is NOT guaranteed to be drawn precisely to scale, though it should be mostly close. :) Note that 3 rays are shown for the beam - the outer ones are NOT the tracking beams of the three-beam pickup, but simply to show the major optical paths. Also note that the waste beam reflected off the beam-splitter (back in the direction of the LDs) is also not shown.
      • The laser diodes for the CD (780 nm, IR) and DVD (650 nm, red) are enclosed in a custom package and are believed to be mounted with their emitting facets separated by less than 0.1 mm. This enables the same optics to be used for both CDs and DVDs. The only parts inside that I can see are the LD chips. There isn't even any environmental protection. However, while the beam from the red LD is far from circular (the only one I tested since the beam profile is easy to see), it is not nearly as asymmetric as the typical edge-emitting LD, with a ratio of perhaps 1.5:1 fast:slow axis. The beam profile is more or less Gaussian. The laser diode drivers are the only active electronics within the optical pickup, consisting of an SMT IC and a few discrete components. (At least, it is believed they are the driver for the laser diodes!)
      • A molded Holographic Optical Element (HOE) implements the diffraction grating to provide the auxiliary beams for tracking. These 1st order diffracted beams may be further split by a very small amount to aid in tracking. It's not possible to account for how terrible the 1st order spots look if this was not deliberate! The HOE may also have corrective optics to optimize the beam profile of the laser diodes. This is not yet conclusive as this beam correction could be inside the laser diode assembly, but the far field beam profile of the DVD (red, 650 nm) laser diode is nearly a perfect Gaussian.
      • The beam than hits a plate beam-splitter. The transmitted portion hits some type of sensor for laser power feedback control.
      • The reflected beam goes through a positive lens. The resulting beam is very well collimated. Testing with the objective lens removed, at 5 meters. it is still around 3 mm in diameter, with no detectable increase in diameter from 1 meter for the 650 nm (red) LD. The beam from the 780 nm (IR) LD is about 1 cm in diameter at 5 meters. For the purposes of the very short optical paths, even this is essentially perfectly collimated.
      • After reflecting off the turning mirror (actually a coated right angle prism), the beam passes through the objective lens, a molded asphere on a two-axis voice coil positioner for focus and tracking.
      • The return beam from the disc retraces the previous steps but the portion that goes through the beam-splitter is what's used by the PhotoDiode Array (PDA). (The reflected beam is wasted.)
      • An angled plate between the beam-splitter and PDA is believed to serve the function of the cylindrical lens in many other pickups - introducing astigmatism for the focus servo. Advantages may be that it's less expensive and requires less critical alignment.
      • The PDA consists of two sets of three 4-quadrant PDs, one for the CD wavelength (780 nm) and the other for the DVD wavelength (650 nm). The spacing for each set is in the ratio 780:650, 1.2:1. The spacing between the sets of PDs is then the same as the separation between the CD and DVD LDs. The 4 quadrant PDs is around 80 µm square. (40 µm for each PD.)
      • The center 4-quadrant PDs are used for data readout and focus control. The outer 4-quadrant PDs are used for tracking.
      The optical pickup in the Philips/Lite-on DS-8A8SH CD/DVD RW drive is virtually identical to the one in the Panasonic UJ8D1. It wasn't even worth putting together a composite photo as the overall appearance is so similar. But see Optical Paths of Philips/Lite-on DS-8A8SH CD/DVD RW Drive. Can you find the differences? ;-) In fact, this pickup may simply be an updated version of the same design.
    Now, what you've all been waiting for: Info on the PS3 Blu-ray optical deck. For many photos and a detailed description and analysis of the laser/optics assembly, extraction and powering of the tri-wavelength laser diode, and much more related to the optical pickup for a PlayStation 3, go to Leslie's Dissection of a Blu-ray Reader Assembly Page or Sam's Copy of Leslie's Dissection of a Blu-ray Reader Assembly Page. The photos there iuclude high resolution versions of some of those above as well as for the HD-DVD drive described below. The sophistication of the technology and what's crammed into an itty-bitty space is absolutely amazing. Compare its complexity to the PS2 PVR-802W, above! The Blu-ray Disc Format White Paper: Key Technologies has some interesting information on technical issues relating to implementation of multi-format optical blocks including the triple wavelength laser diode. There is much information more under "Technical" at the Blu-ray Disc Association Web site. And next, a pickups for HD-DVD. Actually, the first optical block is probably suitable for both HD-DVD and Blu-ray. There is some printing on the main PCB visible in the photo of the top of the device that reads: BD/HDP - the "BD" is likely for Blu-ray Disc. Also, the Wicked Lasers Sonar violet laser pointer uses the laser diode from what appears to be the identical pickup as seen in Sonar Blu-ray Laser: How They Make It - Gizmodo. I labeled it HD-DVD simply because I was originally told it came from an HD-DVD device.
    • This CD/DVD/HD-DVD Optical Block 1 has totally separate beam paths for HD-DVD and CD/DVD. The HD-DVD (violet) laser diode would go on the right feeding into the Polarizing Beam Splitter (PBS, the cube), then a collimating lens, and turning mirror feeding one objective lens. (As with the Blu-ray optical block, above, the actual laser diode is missing.) The top exit of the PBS is from the violet LD and may be some kind of beam quality monitor - it's got way more connections than needed for a simple power monitor. But that is also required as the violet LD has no internal power monitor, which would suggest that the optical block is actually from an HD-DVD or Blu-ray recorder/writer since higher power LDs often don't have internal monitor photodiodes. The bottom exit of the PBS is for the HD-DVD photodiode array. The CD (IR) and DVD (red) combined hologram laser diodes with diffraction gratings and photodiode arrays is under the copper bracket on the left feeding only a fixed collimating lens and turning mirror to the other objective lens. Also note the servo-controlled collimating lens in the HD-DVD beam path. This is also present on the Blu-ray pickup and the next HD-DVD pickup, below.
    • The HD-DVD/DVD/CD Optical Pickup from Toshiba HD-A3 Player is another example. It's also a dual lens pickup but with conventional laser diodes and a somewhat simpler organization.
    • The Toshiba PHR-803T HD-DVD/DVD/CD Optical Pickup is apparently used in the first generation Xbox HD-DVD drive, though the ones I have are from PC HD-DVD ROM drives labeled: SD-H802A. Toshiba PHR-803T HD-DVD/DVD/CD Optical Pickup - Exploded View with Annotation shows the details and Toshiba PHR-803T HD-DVD/DVD/CD Optical Pickup - Closeup of 405 nm Laser Diode is a truly spectacular view inside. (These two Photos courtesy of Karol Luszcz.) This pickup is so much simpler than any of the other similar 3 or more format designs. There is a violet LD for HD-DVD and a combined 780 nm and 650 nm diode for CD and DVD. Each is in a 5.6 mm can. There appears to be a separate photodiode for optical power monitoring, at least for the CD/DVD LD as there are not enough pins. The two LDs are combined in a beam-splitter and after that, their optical paths are identical with only a single objective lens. A beam-splitter plate separates the outgoing and reading beams and there is only a single PD array chip. All the other optical elements are similar to those in a CD or DVD pickup with the exception of an LCD wavefront corrector below the objective lens. This pikcup uses the normal 3-beam tracking with separate diffraction gratings in front of each LD's output. The only other optics are a cylindrical lens (probably cylindrical for focusing, though it may do other stuff) in front of the PD array, and a collimating lens below the LCD. The relative simplicity makes sense though since it doesn't need to support the Blu-Ray (BD) format. BD has much more major differences than HD-DVD compared with CD and DVD. In particular, the NA of the lens is much lower (0.65 compared to 0.85) and the cover layer on the disc is thinner (0.1 mm compared to 0.6 mm). That is probably the reason there is no stepper motor controlled lens in this unit. Upon power up, the unit first attempts to read a DVD, then a CD, and only then turns on the violet diode to read the HD-DVD. If it finds one, then that diode will remain on for a minute or so unless the drive is actually accessed. It's hard to determine the actual power being used for the violet diode, but it doesn't look like it is very high. The red DVD power is almost certainly running under 5 mW. The montage photos show what it looks like in situ when reading a DVD with the red (650 nm) laser diode and an HD-DVD with the violet (405 nm) laser diode. My digital camera refuses to reproduce a decent violet! :) I was unable to capture the similar IR (780 nm) when reading a CD but it would have the same beam path as for the DVD.
    • The Toshiba DRO-811 HD-DVD/DVD/CD Optical Pickup is very similar and possibly even a bit simpler.

    Components of the optical pickup

    All the parts described below are in the optical pickup. As noted, the optical pickup is usually a self contained and replaceable subassembly. The actual complement and arrangement of parts depends on the specific pickup design - a number of popular variations on the basic arrangement are used. Thus, should you actually end up dismantling a dead optical pickup, it will probably not match this description exactly. While the relatively old Sony KSS110C Optical Pickup has most of the same components as described below, the very common newer Sony and Sanyo optical pickups combine multiple functions into fewer elements. Typical examples are found in the Sony KSS361A Optical Pickup and Sanyo K38N Optical Pickup. The even simpler CMKS-81X Optical Pickup and Optical Pickup from Philips PCA80SC CDROM combine the laser diode and photodiode array into single package and eliminate all of the other optical components except for the diffraction grating and turning mirror (and the latter could be eliminated where space permits below the deck). The resulting designs are much cheaper to manufacture, more robust and reliable, and should have better performance as well since there are fewer intermediate optical components to degrade the beam.
    Also see the section: CD optical pickup operating principles. Despite its being a precision optomechanical device, optical pickups are remarkably robust in terms of susceptibility to mechanical damage.
    • Laser Diode - This is Infra Red (IR) emitting usually at 780 nm - near IR, just outside the visible range of 400-700 nm. The power output is no more than a few milliwatts though this gets reduced to 0.25-1.2 mW at the output of the objective lens. A photodiode inside the laser diode case monitors optical power directly and is used in a feedback loop to maintain laser output at a constant and extremely stable value. The photos below show some of the types of laser diodes you may encounter in CD players, CDROM drives, laser printers, and bar code scanners: On an increasing number of pickups, the laser diode and photodiode array are combined into a single package. These are recognizable by their 8 or 10 lead package. See the section: Optical pickup complexity. Common problems: bad laser diode or sensing photodiode resulting in reduction or loss of laser output.
    • Photodiode array - This is the sensor which is used to read back data and control beams. These are usually integrated into a single chip with a clear plastic cover. On an increasing number of pickups, the laser diode and photodiode array are combined into a single package. These are recognizable by their 8 or 10 lead package. See the section: Optical pickup complexity. The photodiode array for a three-beam pickup has 6 segments - 4 in the center (A,B,C,D) and 1 on either side (E,F). Only the center segments are used in a single-beam pickup. However, there are some CD players and CDROM drives are fitted with complete three-beam pickups, but don't take advantage of the side beams - the E and F segments of the photodiode array are simply grounded! So, the blurb for these models may say "Featuring three-beam pickup" when only a single-beam is used! Isn't marketing wonderful? :-). Common problems: bad photodiode(s) resulting in improper or absence of focus and weak or missing RF signal. A missing bias voltage to the photodiode array would also result in lack of output.
    • Collimating lens - This converts the wedge shaped beam of the laser diode into nearly parallel rays. Not present in many (newer) designs.
    • Diffraction grating - In a 'three-beam pickup', this generates two additional lower power (first order) beams, one on each side of the main beam which are used for tracking feedback. It is absent in a 'single-beam pickup'.
    • Cylindrical lens - In conjunction with the collimating lens, this provides the mechanism for accurate dynamic focusing by changing the shape of the return beam based on focal distance. Modern pickups may actually use a thick beam splitter mirror or astigmatic objective lense to implement this function and/or take advantage of the natural astigmatism of the laser diode itself. The thick mirror approach is used in most common Sony KSS pickups, for example.
    • Beam splitter - Passes the laser output to the objective lens and disc and directs the return beam to the photodiode array. There will be no beam splitter (and related optics) if the laser diode and photodiode are combined in a single package. Where this is a thick mirror, it also introduces the needed astigmatism for focusing (most Sony KSS pickups, for example).
    • Turning mirror - Redirects the optical beams from the horizontal of the optical system to vertical to strike the disc. Where space permits under the pickup, there is no need for a turning mirror as everything can be vertically oriented. Common problems: dirty mirror. Unfortunately, this may be difficult to access for cleaning. Note: the turning mirror is probably not silvered but is coated to reflect IR so do not be surprised if you can see through it.
    The previous five items are the major components of the fixed optics. Outside of damage caused by a serious fall, there is little to go bad. Better hope so in any case - it is usually very difficult to access the fixed optics components and there is no easy way to realign them anyhow. Fortunately, except for the turning mirror, it is unlikely that they would ever need cleaning. Usually, even the turning mirror is fairly well protected and remains clean. Depending on the design of the pickup, many of the components of the optical system listed above may be missing or combined into a single unit. In fact, the most modern pickup designs combine the laser diode and photodiode into a single package with 8 to 10 leads. With this approach, there is no need for a beam splitter or related optical components as the outgoing and return beams take nearly the same path. The overall manufacturing process is simplified, performance is improved, the cost is reduced, and reliability and robustness are enhanced. See the section: Optical pickup complexity. The following items are associated with focusing the laser beam down to a microscopic point and maintaining it precisely on the CD's tracks:
    • Objective lens - High quality focusing lens, very similar to a good microscope objective with a numerical aperture (N.A.) of 0.45 and focal length of 4 mm. (Should you care, the N.A. is defined as the sine of the angle from the optical axis to the edge of the objective, as seen by the object. An N.A. of 0.45 implies a very fast high quality lens.) If you examine CD player objective lenses closely, you will also note that they are aspheric - the surface is not shaped like the surface of a sphere (as is the case with most of the small lenses you are likely to encounter) but its radius of curvature changes from center to edge (it is somewhat pointed). Because the light source (laser diode) is coherent and monochromatic, a low cost single element plastic molded lens with an antireflection coating (the blue tinge in the central area) can produce a diffraction limited spot (less than 2 um in diameter) at the disc information (pits) layer. An expensive multielement lens system would be required if the light source were not coherent and monochromatic. Of course, the entire technology would not be practical in this case! There is usually a ridge around its periphery to prevent the polished surface from being scratched should the assembly accidentally contact the spinning disc. Note: Some objective lenses (e.g., Philips/Magnavox) have a perfectly flat front surface. This would appear to be more susceptible to damage but perhaps a mechanical stop prevents contact even at the extreme upper limit. The lens is suspended to permit movement in two directions: up and down (focus) and toward and away from the spindle (tracking). Common problems: dirty lens, dirt in lens mechanism, scratched lens, damage from improper cleaning or excessive mechanical shock.
    • Focus actuator - Since focus must be accurate to 1 micron - 1 um, a focus servo is used. The actuator is actually a coil of wire in a permanent magnetic field like the voice coil in a loudspeaker. The focus actuator can move the objective lens up and down - closer or farther from the disc based on focus information taken from the photodiode array. Common problems: broken coil, damaged suspension (caused by mechanical shock or improper cleaning techniques).
    • Tracking actuator - Like focus, tracking must be accurate to 1 um or better. A similar voice coil actuator moves the objective lens from side-to-side (relative to the tracks - toward or away from the spindle) based on tracking feedback information taken from the photodiode array. Note: On pickups with rotary positioners, there may be no separate tracking coil as its function is subsumed by the positioner servo. The frequency response of the overall tracking servo system is high enough that the separate fine tracking actuator is not needed. These are also always of the single-beam type since the angle of the pickup changes with radial position and three-beam tracking control cannot be used. Common problems: broken coil, damaged suspension (caused by mechanical shock or improper cleaning techniques).

    Comparison of semi-antique and modern optical pickups

    Despite great strides in miniaturization, the basic functions that need to be performed by an optical pickup haven't changed since the development of optical recording in the late 1970s. The organization of the optical pickup in the earliest helium neon laser-based LaserDisc players is virtually identical to that of a modern DVD optical pickup. Now, granted, it was a massive casting with dimensions of around 5"x12"x2" compared to 3/4"x1"x0.3" for the modern one in a laptop computer DVD drive. But all the same parts are present in both. See Optical Pickup from HeNe Laser-Based LaserDisc Player. That entire assembly moved on roller bearing slides for coarse tracking and weighs at least 2 pounds! Additional photos of this and another vintage LaserDisc player guts can be found in the Laser Equipment Gallery under "Miscellaneous Lasers, Power Supplies, Components, and Accessories". Compare these optical pickups with General Three-Beam Optical Pickup Organization. The only real difference other than size and weight is that instead of moving the objective lens via a coil actuator for fine tracking, there is a mirror deflector for this purpose. And there is another mirror deflector for "tangential correction" which performs video timebase correct, an LD-only function. But the objective lens is still moved by a coil for focus, and the polarizing beamsplitter, three-beam diffraction grating, 1/4 wave waveplate, and photodiode array are separate components. And look at all those adjustments! :) There is a Web site with some information on the first consumer LD player - the Pioneer VP-1000, one of those that used the same huge pickup. See Pioneer Laser-Optical Videodisc Player Introduction. Another useful LaserDisc Web site is Laserdisc Archive UK, which also includes links to other LaserDisc-related Web sites of interest.
    I recently acquired a Pioneer VP-1000 in working condition. Considering its age of roughly 25 years, this is rather remarkable. Except for a sometimes quirky startup, it operates flawlessly. They used to build these things to last! :) The startup problem was that the pickup didn't go back to the home position - a gentle push generally reset it until the next time a LaserDisc was played and then stopped. Adjusting the home position sensor (a microswitch) seems to have mostly cured it, though that may be masking some other underlying cause. I don't think it was a lubrication or similar issue as as the pickup moves freely on its rail and everything is clean with no grease ever being used. Some possibilities include the need for an electronic adjustment or a slight optical misalignment, or a weak laser, since it appears to fail to achieve focus lock unless starting on the mirrored inner portion of the disc, not the area with the video. However, given the flawless playback, the latter two faults don't seem very likely. A diagram of an even earlier LaserDisc pickup prototype is shown in Optical Path of Early HeNe Laser-Based LaserDisc Prototype. The Wollaston prism is a rather unusual optic which probably never made its way into any commercial unit due to the small separation the polarized beams and its extremely high cost. The Pioneer LaserDisc player, above, used a more conventional polarizing beamsplitter cube (still costly but much less so than the Wollaston), and more recent CD and DVD pickups typically use an even cheaper dielectric coated plate beamsplitter. But otherwise, the designs are very similar. However, some of the newest cost-reduced pickups do away with the polarizing components entirely by offsetting the outgoing and return beams. This probably reduces the performance slightly, but who can argue with the bean counters?

    Classification of CD player problems

    While there are a semi-infinite number of distinct things that can go wrong with a CD player, any set of symptoms can be classified as a hard failure or a soft failure:
    1. Hard failure - door opening/closing problems, disc is not recognized, no sound, unit totally dead.
    2. Soft failure - skips, continuous or repetitive audio noise, search or track seek problems, random behavior.
    Both of these types of problems are common with CD players and CDROM drives. The causes in both cases are often very simple, easy to locate, and quick and inexpensive to repair.

    Most common CD player problems

    While it is tempting to blame the most expensive component in a CD player or CDROM drive - the laser - for every problem, this is usually uncalled for.
    Here is a short list of common causes for a variety of tracking and audio or data readout symtoms:
    • Dirty optics - lens, prism, or turning mirror.
    • Drawer loading belts - worn, oily, flabby, or tired.
    • Sticky mechanism - dirt, dried up/lack of lubrication, dog hair, sand, etc.
    • Broken (plastic) parts - gear teeth, brackets, or mountings.
    • Need for electronic servo adjustments - focus, tracking, or PLL.
    • Intermittent limit or interlock switches - worn or dirty.
    • Bad connections - solder joints, connectors, or cracked flex cable traces.
    • Motors - electrical (shorted, dead spot) or mechanical (dry/worn bearings).
    • Laser - dead or weak laser diode or laser drive (power) problems.
    • Photodiode array - bad, weak, or shorted segments or no power.
    • Bad/heat sensistive electronic components.
    • Bad or missing optical pickup shield ground.
    The following two areas cover the most common types of problems you are likely to encounter. For any situation where operation is intermittent or audio output is noisy, skips, or gets stuck, or if some discs play and others have noise or are not even recognized consistently, consider these FIRST:
    • Dirty lens - especially if your house is particularly dusty, the player is located in a greasy location like a kitchen, or there are heavy smokers around. Cleaning the lens is relatively easy and may have a dramatic effect on player performance.
    • Mechanical problems - dirt, dried up lubrication, damaged parts. These may cause erratic problems or total failure. The first part of a CD may play but then get stuck at about the time location. If your CD player has a 'transport lock' screw, check that it is in the 'operate' position before breaking out the heavy test equipment!

    Troubleshooting Guide

    Instant troubleshooting chart - most common problems and likely causes

    The following chart lists a variety of common problems and nearly all possible causes. Diagnostic procedures will then be needed to determine which actually apply. The 'possible causes' are listed in *approximate* order of likelihood. Most of these problems are covered in more detail elsewhere in this document.
    While this chart lists many problems, it is does not cover everything that can go wrong. However, it can be a starting point for guiding your thinking in the proper direction. Even if not listed here, your particular problem may still be dealt with elsewhere in this document.
    • Problem: CD player is totally dead.
      Possible causes:
      1. Power outlet, wall adapter, or batteries are dead (as appropriate).
      2. Damage to line or wall adapter cord or plug.
      3. Bad connections or faulty component in power supply (including blown fuse).
      4. Defective microcontroller.

    • Problem: CD player is operational but there is no display or partial display.
      Possible causes:
      1. Burned out back-light bulb(s).
      2. Bad connections to display panel (totally dead or erratic).
      3. Bad solder connections on display panel (some segment work).
      4. Bad power supply (EL panel filament, driver voltages).

    • Problem: CD player ignores you.
      Possible causes:
      1. Bad connections to one or more buttons or sets of buttons.
      2. Microcontroller failed to reset properly.
      3. Missing/bad voltages from power supply.
      4. Defective microcontroller or other logic.

    • Problem: Drawer does not open or close.
      Possible causes:
      1. Worn, stretched, oily, flabby, belt.
      2. Dirty mechanism or gummed up lubrication.
      3. Stripped gear or other mechanical damage.
      4. Defective motor or bad connections to motor.
      5. Bad drawer/eject button.
      6. Missing/bad voltages from power supply.
      7. Defective microcontroller or other logic.
      8. Dealer antitheft lock enabled.

    • Problem: Drawer operation is erratic.
      Possible causes:
      1. Dirty sense switch contracts or bad connections.
      2. Worn, stretched, oily, flabby, belt.
      3. Dirty mechanism or gummed up lubrication.
      4. Defective motor or bad connections to motor.
      5. Stripped gear or other mechanical damage.
      6. Missing/bad voltages from power supply.
      7. Defective microcontroller or other logic.

    • Problem: Drawer does not close (or open) completely.
      Possible causes:
      1. Worn, stretched, oily, flabby, belt.
      2. Dirty mechanism or gummed up lubrication.
      3. Foreign object like toy, rock, or runaway disc blocking drawer.
      4. Stripped gear or other mechanical damage.
      5. Gear timing is messed up.

    • Problem: CD changer jams when selecting or ejecting CDs.
      Possible causes:
      1. Bad belts, dirt or need for lubrication.
      2. Foreign objects, chipped or broken gears, or other mechanical damage.
      3. Messed up gear timing.
      4. Defective sensor (microswitch or opto-interrupter.
      5. Defective motor, driver, or power supply.
      6. Logic or microcontroller problem.

    • Problem: CD player or CDROM drive damages CDs.
      Possible causes:
      1. Broken, bent, or missing part.
      2. Messed up gear timing (mainly cartridge changers).
      3. Other mechanical fault.
      4. Lens hitting CD due to electronic fault or need to adjust focus servo.

    • Problem: Spindle table loose or sticks to clamper upon eject.
      Possible causes:
      1. Set screw loosened or glue failed holding spindle to motor shaft.
      2. Parts of spindle table broke.

    • Problem: Intermittent or erratic operation.
      Possible causes:
      1. Dirty, scratched, or defective disc.
      2. Dirty lens.
      3. Extended length discs too long for player.
      4. Loading (mechanical) not completed reliably.
      5. Bad connections including missing/erratic optical deck shield.
      6. Cracks in ribbon cable to optical pickup.
      7. Dirty drawer or limit switches.
      8. Power supply or logic problems.
      9. External interference.
      10. Internal damage (e.g., loose parts) in optical pickup.

    • Problem: CD player or CDROM drive overheats.
      Possible causes:
      1. Excessive ambient temperature - sauna or hot stereo components.
      2. Failing/marginal part in power supply, logic, or optical pickup.

    • Problem: Operation is poor or erratic when cold:
      Possible causes:
      1. Gummed up grease or dirt inhibiting movement until warm.
      2. Condensation on optical components due to temperature change.
      3. Bad connections or dirty contacts affected by temperature.

    • Problem: Disc is not recognized displaying 'disc', 'error', etc.
      Possible causes:
      1. Disc loaded upside-down.
      2. Transportation lock engaged.
      3. Dirty, scratched, or defective disc.
      4. Dirty or damaged objective lens.
      5. Loading (mechanical) not completed reliably.
      6. Damaged lens suspension or damaged lens cover preventing free movement.
      7. Dirt, gummed up lubrication, or damage in sled drive mechanism.
      8. Dirty/defective limit switch or sensor.
      9. Defective spindle motor.
      10. Spindle table height incorrectly set.
      11. Bad component in optical pickup.
      12. Cracks in ribbon cable to optical pickup.
      13. Need to adjust servo (or less likely, optical) alignment.
      14. Faulty power supply, electronics, or control logic.
      15. Bad connections including missing/erratic optical deck shield.
      16. External interference.

    • Problem: Disc spins in wrong direction or overspeeds and is never recognized.
      Possible causes:
      1. Disc loaded upside-down.
      2. Dirty, scratched, or defective disc.
      3. Dirty or damaged objective lens.
      4. Tracking or CLV servo out of adjustment or faulty.
      5. Bad component in optical pickup.
      6. Microcontroller or control logic problems.
      7. Bad connections or defective ribbon cable to optical pickup.
      8. Defective spindle motor including worn bearings.

    • Problem: Pickup attempts to reset past inner track.
      Possible causes:
      1. Dirty or defective limit switch, bad connections to it, or its electronics.
      2. Broken parts preventing limit switch from being activated.
      3. Tracking servo out of adjustment or faulty.
      4. Microcontroller or logic problems.

    • Problem: Player won't let you go near it and/or use your favorite lamp.
      Possible causes:
      1. Missing optical deck shield, ground strap, or other connection.
      2. Outside interference.

    • Problem: Seek operations take too long or fail to complete.
      Possible causes:
      1. Dirty, scratched, or defective disc.
      2. Transportation lock engaged.
      3. Dirty or damaged objective lens, suspension, obstruction, etc.
      4. Tracking or CLV servo out of adjustment or faulty.
      5. Mechanical problems with sled movement.
      6. Faulty sled motor or drive IC.
      7. Faulty control logic.
      8. Bad flex cable to optical pickup.

    • Problem: Search, seek, or play starts correctly, then loses time or position.
      Possible causes:
      1. Dirty, scratched, or defective disc.
      2. Dirty or damaged objective lens, suspension, obstruction, etc.
      3. Tracking or PLL servo out of adjustment or faulty.
      4. Stuck button.
      5. Defective sled motor drive IC.
      6. Faulty control logic.

    • Problem: Short distance skipping.
      Possible causes:
      1. Dirty, scratched, or defective disc.
      2. Dirty or damaged objective lens, suspension, obstruction, etc.
      3. Fine tracking servo out of adjustment or faulty.
      4. Weak laser or other defective part in the optical pickup.

    • Problem: Playback gets stuck (rapid repeat).
      Possible causes:
      1. Dirty, scratched, or defective disc.
      2. Dirty or damaged objective lens, suspension, obstruction, etc.
      3. Dirt, gummed up lubrication, or damage in sled drive mechanism.
      4. Transportation lock engaged.
      5. Need for servo alignment.

    • Problem: Occasional long distance skipping or repeating.
      Possible causes:
      1. Dirty, scratched, or defective disc.
      2. Dirty or damaged objective lens, suspension, obstruction, etc.
      3. Dirt, gummed up lubrication, bad belt, or damage in sled drive mechanism.
      4. Transportation lock engaged.
      5. Need for servo alignment.

    • Problem: Player gets stuck at approximately same time on multiple discs.
      Possible causes:
      1. Dirt, gummed up lubrication, or damage in sled drive mechanism.
      2. Sled reaching mechanical stop with extended length (>74 minute) disc.
      3. Transportation lock engaged.
      4. Need for servo alignment.
      5. Defective spindle motor.

    • Problem: Various tracking problems on portions of discs:
      Possible causes:
      1. Dirty, scratched, or defective disc.
      2. Faulty spindle motor.
      3. Misalignment of spindle table and sled track.
      4. Need for CLV adjustment.

    • Problem: Repetitive noise at disc rotation rate.
      Possible causes:
      1. Dirty, scratched, or defective (possibly warped) disc.
      2. Dirty or damaged objective lens, suspension, obstruction, etc.
      3. Loose spindle or foreign material on spindle table.
      4. Disc not firmly clamped.
      5. Bent spindle.
      6. Excessive spindle runout due to worn bearing.
      7. Need for servo alignment.
      8. Weak laser or other component in optical pickup.

    • Problem: Audio muting, noise, or distortion.
      Possible causes:
      1. Dirty contacts on RCA jacks on CD player or amp.
      2. Bad connections to RCA jacks.
      3. Dirty/defective muting relay contacts.
      4. Defective components in the analog circuitry (final filter, muting, amp).
      5. Faulty power supply (for audio circuits if used).
      6. Dirty controls (probably on amp unless problem is with the headphones).

    General inspection, cleaning, and lubrication

    The following should be performed as general preventive maintenance or when erratic behavior is detected. The lens and its suspension, turning mirror, drawer mechanism, spindle, and sled drive should be checked, and cleaned and/or lubricated if necessary and appropriate.
    You will have to get under the clamp to access the lens and spindle on drawer loading models but the lens and its suspension, at least, should be readily accessible on portable CD players with pop-up doors. These types can collect a lot of dust, dirt, and even fingerprints! Realistically, you probably won't do any of this for component CD players, CDROM drives, or other drawer loading models until something goes wrong! :-) (I don't blame you - getting one of those out from the tangle of entertainment center wiring, dusting it off, removing the cover, disassembling to whatever level is needed, and so forth can be a royal pain.) Cleaning the objective lens and turning mirror (if accessible) are the most important general maintenance that can be done. Even minor contamination of their optical surfaces can easily result in 50 percent reduction in the returned signal - and all sorts of problems.
    • Objective lens - Carefully clean the lens assembly. Be gentle! The lens is suspended by a voice coil actuated positioner which is relatively delicate. A CD lens cleaning disc is nearly worthless except for the most minor dust as it will not completely remove grease, grime, and condensed tobacco smoke products (yet another reason not to smoke!) and make matters worse by just moving the crud around. First, gently blow out any dust or dirt which may have collected inside the lens assembly. A photographic type of air bulb is fine but be extremely careful using any kind of compressed air source. Next, clean the lens itself. It is made of plastic, so don't use strong solvents. There are special cleaners, but isopropyl alcohol us usually all that is needed for CD players and VCRs. (91% medicinal is acceptable, pure isopropyl is better. Avoid rubbing alcohol especially if it contains any additives.) However, sometimes, a drop of water will be needed to dissolve sugar based crud. There should be no problems as long as you dry everything off (gently!) reasonably quickly. DO NOT LUBRICATE! You wouldn't oil a loudspeaker, would you? You cannot generally get to the bottom surface of the lens but this isn't nearly as exposed as the top surface so it usually isn't a problem. However, a few models do permit removal and replacement of the entire objective lens assembly without realignment. In such a case, you can get to the bottom of the lens as well as additional optics surfaces (see below) for cleaning. Do NOT use strong solvents or anything with abrasives - you will destroy the lens surface rendering the entire expensive pickup worthless.
    • Now, inspect the lens. When clean, the lens should be perfectly shiny with a blue tinge uniform over the central surface. Minor (barely visible) scratches will probably cause no harm but any major scratches may result in erratic tracking or total inability to even read the disc directory. The pickup (or lens assembly) will need to be replaced in this case. It is easy to be misled into thinking that there are serious problems at the root cause of discs not being recognized, audible noise (CD players) or data errors (CDROM or optical drives), and tracking problems like skipping, sticking, or seek failures. However, in many cases, it is simply a dirty lens! Even people who repair CD players regularly may make an incorrect diagnosis since many of the symptoms **are** similar to those caused by a bad laser, spindle motor, or major logic failure.
    • Turning mirror or prism. If you can get to it under the lens without disturbing anything, clean this as well using the same procedure. Cleaning this may be at least as important as the lens. Unfortunately, the turning mirror may not be accessible without major (and difficult) disassembly. Cleaning the turning mirror is nearly as important as cleaning the lens (especially for Sony pickups apparently since it is relatively exposed). However, for the typical Sony pickup (also used in Sony PlayStations and by AIWA and other manufacturers), it is really pretty easy. First, remove the black protective cover by prying the clips out on either side. Use a toothpick or Q-tip stick to GENTLY lift up on the lens assembly taking care not to damage any of the fine wires. Blow out any dust using an air bulb. There will be just enough room to get a Q-tip in between the lens and mirror. Note: The turning mirror is not silvered so don't expect a normal mirror appearance - it looks just like a piece of glass. However, it is coated to be an excellent reflector for the 780 nm IR laser light. Of course, this procedure doesn't get to the beam splitter, photodiode, or laser diode window - but you can't have everything! :-) Fortunately, these are usually better protected and less likely to collect dust and grime.
    • Lens suspension for focus and tracking. Check this for free movement and damage:
      • Focus: The lens should move up and down without sticking (turn the player or pickup upside-down carefully to watch the lens move without power and/or move it gently with a dry Q-tip). It should remain parallel to the deck throughout its range and return to the center or just below center when released. However, it is hard to say just how far below the center is enough to consider it bad. Even a bottomed out lens might work - the focus servo can correct to a large extent - but could result in more susceptibility to skipping or other erratic operation particularly with less-then-perfect discs. Also, see the section: Comments on Sony KSS pickup suspension problems
      • Tracking: Use a Q-tip to gently move the lens toward and away from the spindle. It should move easily without sticking and remain parallel to the deck. When released, it should return to approximately the middle position.
      A suspension which fails any of these tests probably means replacement of the pickup - or CD player - is needed. However, the lens with its suspension is one of the few components of the optical pickup assembly that may be replaceable - at least in principle. See the section: Interchangeability of components in the optical pickup.
    • Spindle bearing - Check the spindle bearing (this is primarily likely to cause problems with repetitive noise). There should be no detectable side to side play. I.e., you should not be able to jiggle the platform that the CD sits on. If you find that the bearings are worn, it is possible to replace the motor (about $10 from various mail order houses), though removing and replacing the disc platform may prove challenging as a result of the usual press fit mounting. The focus servo can compensate for a vertical movement of the disc surface of 1 mm or so. A small bearing side play can easily cause larger vertical errors - especially near the end (outer edge) of the disc. Even if you are not experiencing problems due to bearing wear, keep your findings in mind for the future. Sometimes there is a bearing runout adjustment screw on the bottom of the spindle if the spindle is not driven by a standard permanent magnet motor. I have seen this in a Sony Discman which had a custom motor assembly. A small tweak to this may fix a marginal spindle problem.
    To access the drawer mechanism and sled drive in component units, you will probably need to remove the optical deck from the chassis. It is usually mounted by 3 long screws (one of which may have a grounding doodad - don't lose it. In portables and CDROMs, the bottom panel of the unit will need to be removed. Try not to let any of the microscrews escape! A good set of jeweler's screwdrivers is a must for portables.
    • Drawer mechanism (if present) - Check for free movement. Test the belt (if used) for life - it should be firm, reasonably tight, and should return to its original length instantly if stretched by 25% or so. If the belt fails any of these criteria, it will need to be replaced eventually, though a thorough cleaning of the belt and pulleys with isopropyl alcohol (dry quickly to avoid damaging the rubber) or soap and water may give it a temporary reprieve. Some models may use other types of drawer mechanisms but similar recommendations apply. Also, check the gears and motor for lubrication and damage and correct as necessary. Clean and lubricate (if necessary) with high quality light grease suitable for electronic mechanisms such as MolyLube or Silicone grease. A drop of light oil (electric motor oil, sewing machine oil) in the motor bearings may cure a noisy or dry bearing.
    • Sled drive - check the components which move the pickup including (depending on what kind of sled drive your unit has) belt, worm gear, other gears, slide bearings. These should all move freely (exception: if there is a lock to prevent accidental damage while the unit is being transported the pickup may not move freely or very far). Inspect for damage to any of these components which might impede free movement. Repair or replace as appropriate. If the there is evidence of dirty or hardened grease, clean the gears and track thoroughly as this may interfere with free movement. Use a sharpened toothpick or (very carefully) a pin or other tool to get in between each of the gear teeth as well to be sure that it is not hard and caked there as this may result in erratic operation and skipping. Then lubricate (if necessary) with just a dab of high quality light grease suitable for electronic mechanisms such as MolyLube or Silicone grease). A drop of light oil (electric motor oil, sewing machine oil) in the motor bearings may cure a noisy or dry bearing. Also see the section: Testing the sled for mechanical problems.
    Try to play a disc again before proceeding further. I guess you have already done this.

    Notes on DVD problems


    (Mostly from: Arfa Daily.) Due to the high rotation speed of DVDs, the flow generally prevents dust from settling on the like in CD players. Exceptions to this are if the player is located in a country or area that is very dry, or if the player is located in a heavy smoking environment or possibly in a kitchen where vapors from cooking are present. Playability problems are most often associated with a worn laser, although one year does seem a little on the 'young' side. That said, if the player gets heavy use, it is by no means unheard of for a laser of just one year to be showing signs of wear, and of course, none of this precludes the possibility of the laser being defective. Other causes of playability problems include mechanical defects on the deck, iffy spindle motors and 'marginal' caps on the power supply.
    Where freezes tend to occur late in a two-layer DVD, this is usually a good indicator of laser trouble, as it is much more difficult for it to read layer two through layer one. A further test that you can run is to try playing some full-length commercially pressed CDs. If these play without problem, this pretty much verifies the mechanics, and is another pointer for laser trouble. By all means try cleaning the lens, but do not use a lens cleaner disc, as this is unlikely to help, and can on some machines, cause physical damage to the laser assembly. Access is usually available once the optical block has been slid down its tracks towards the back of the deck, which brings it out from under the disc clamp. The lens should be cleaned carefully with a cotton bud (Q-Tip) moistened (not wet) with electronics grade isopropyl alcohol. The lens suspension is fairly delicate, so don't be 'brutal' with it, but by the same token, it is not so delicate that it is easily damaged. Just use common sense. When the alcohol has evaporated, polish the lens with a new clean and dry cotton bud. The only symptom that you describe, which is a little 'odd' is that discs seem to start from odd places rather than the beginning, although that might just be being caused by the laser having trouble getting a good error-free data stream off the disc.

    Cleaning the inside of the optical pickup

    Except under extreme circumstances (like dropping the CD player in the bathtub), the interior of the optical pickup should remain relatively clean and dust-free. However, what happens if you DO drop the CD player in the bathtub? Well, there will no doubt be other problems to deal with but once those are taken care of (if ever), that leaves the optical pickup.
    For many, the turning mirror is accessible by gently lifting up on the lens assembly after removing the protective shroud. But, even this may not be possible for some models. And, cleaning all of the other optics may be difficult or impossible. For example, on many Sony models, there is a metal plate fastened with a single screw underneath the pickup. This plate can be removed without disturbing any adjustments revealing the angled beam splitter and diffraction grating (of the three beam pickup) in the barrel attached to the laser diode. These can be cleaned with a Q-tip and alcohol. However, there is no way to get beyond this point. So, if any water got in there, the only chance of success would be via an alcohol? soak. Forget about further disassembly - realignment would be totally impossible without the factory jigs. A replacement pickup will probably be needed. Each manufacturer has their own way of assembling a pickup. The only way to determine if access is possible will be by careful exploration!

    Lubrication of CD players

    The short recommendation is: DO NOT add any oil or grease unless you are positively sure it is needed. Most moving parts are lubricated at the factory and do not need any further lubrication over their lifetime. Too much lubrication is worse then too little. It is easy to add a drop of oil but difficult and time consuming to restore an optical pickup that has taken a bath.
    NEVER, ever, use WD40! WD40 is not a good lubricant despite the claims on the label. Legend has it that the WD stands for Water Displacer - which is one of the functions of WD40 when used to coat tools for rust prevention. WD40 is much too thin to do any good as a general lubricant and will quickly collect dirt and dry up. A light machine oil like electric motor or sewing machine oil should be used for gear or wheel shafts. A plastic safe grease like silicone grease or Molylube is suitable for gears, cams, or mechanical (piano key) type mode selectors. Never use oil or grease on electrical contacts. Unless the unit was not properly lubricated at the factory (which is quite possible), don't add any unless your inspection reveals the specific need. In a CD player or CDROM drive, there are a very limited number of failures specifically due to lubrication. Note that in most cases, oil is for plain bearings (not ball or roller) and pivots while grease is used on sliding parts and gear teeth. If the old lubricant is gummed up, remove it and clean the affected parts thoroughly before adding new oil or grease. In general, do not lubricate anything unless you know there is a need. Never 'shotgun' a problem by lubricating everything in sight! You might as well literally use a shotgun on the equipment!

    Portable DVD players with display

    These gadgets vary in size from just over 2 or 3 stacked CD jewel cases to that of a small notebook computer. They usually play a variety of disc formats besides normal movie DVDs and audio CDs. Some have memory card slots and can display digital photos and other formats. Screen size ranges from 5 to 10 or more inches diagonal. Typical screen resolution is between 480 (H) x 200 (V) and 1000 (H) x 600 (V) but lower and higher are possible. For a tiny screen even 320 (H) x 200 (V) isn't really that bad. But even with a high resolution LCD, DVD playback may much less. Most models have a variety of A/V inputs and outputs and can thus drive an external TV or double as a portable TV monitor. Both interlaced and progressive scan may be supported.
    Note that since most notebook/laptop computers will play DVDs these days and have bigger better screens and much more flexibility, it only makes sense to have a separate portable DVD player for the kids in the car or where small size and weight are paramount. Electronically, a portable DVD player is simply a combination of a DVD reader and LCD display. Repair is most readily accomplished by swapping of major components - DVD reader (optical deck and pickup), mainboard, LCD backlight inverter, and LCD panel. And, of course, the battery. These are readily available either individually, or as part of a broken unit of the same model on eBay at prices far below that of repair parts supplies - assuming repair parts are available at all elsewhere.
    • Won't power on (AC): Check the outlet and AC adapter. If there is no power indicator, use a multimeter on DC V to test for the proper voltage. Make sure the correct AC adapter is being used! For a slide switch, make sure it is engaging. On some Toshiba units, a tiny plastic piece on the slide swtich can break off preventing the switch from functioning.
    • Won't power on (battery): Check on AC. If it functions on AC, try recharging the battery for the recommended time (usually several hours) and try again. Note that many of these players will *only* charge the battery when off. Check the power connector and battery contacts for damage. The battery could be bad.
    • Short battery life: Make sure you are allowing adequate charge time. There should be some indication when charge is complete such as an indicator going off or changing color. However, after a large number of charge/discharge cycles, the battery capacity will be reduced. A new battery is probably in your future.
    • Display blank but player seems to function otherwise: Assuming there is no obvious damage but there is no light on the screen at all (check in a dark room), shine a flashlight on the screen and look for any evidence of a picture. If there is, then the backlight isn't working either due to a bad inverter or burnt out or broken cold cathode fluorescent tube. If there is no evidence of a picture, check the switch that shuts off the display when the cover is closed - it may be stuck or defective.
    • Display blank and player doesn't read discs: This could be a power or processor problem.
    • Messed up display (all modes): Check for a loose connector or broken wires between the LCD and mainboard (especially if moving the cover back and forth changes anything). This could also be a bad LCD (driver) problem requiring replacement of the LCD panel. Stationary horizontal or vertical lines or bands usually indicate a bad LCD. Try an external video input if available.
    • Poor brightness or contrast: If the user controls (knobs or digital adjustment) don't help, there may be internal pots for these. However, any major change indicates a failure, not the need for an adjustment unless the LCD was swapped (and even then, there should not be that big a change).
    • Missing audio: If only one or both built-in speakers are dead but the headphones work, check for broken wires or a loose plug between the speakers and mainboard. If there is no audio even for the headphones, then it may be a processor problem and require a replacement mainboard as there are generally few discrete components that are serviceable.
    • DVD or CD loading problems: This means that DVDs are not recognized ("no disc" message). If a DVD won't load but a CD will, then it may be a pickup problem. For portables, most likely would be a dirty lens or debris in the pickup (even a loose screw since there are magnets that will attract them!). Where it doesn't even attempt to read a disc, could also be a bent or broken interlock that doesn't engage when the lid is closed. Of course, make sure the DVD is in good condition, clean, and label side up! If the laser works (defeat the door closed switch and check for the red DVD laser to come on) but the disc doesn't spin, or spins sluggishly, the spindle motor may need cleaning. See the section: Motors and Spindles.
    • DVD play problems: Where the DVD loads quickly and starts playing without excessive delay, but the picture is all messed up - noisy, flashing, pixellated, or blocky - there may be a fault in the processor or its memory. Aside from looking for cracked solder joints on the mainboard, there isn't much that can be done without replacing the mainboard since the main processor is usually a chip with over 100 legs. :( :) Where the problems are more sublte - picture freezes or the system locks up, or there are random artifacts on the screen, the lens may be dirty, the DVD may be dirty or damaged, or the pickup may be faulty.
    • Button problems: Where some buttons don't work, check that the cable to the button panel is secure - reseat it to be sure. Since the buttons may be very low profile with very short travel, any wear (such as from pounding on the Play and Stop buttons!) may result in an inability to activate its switch. Disassembly and careful shimming should cure it. Replacement button panels are generally available. However, note that some buttons may not work in all modes so what you're seeing may be normal.
    • Remote control doesn't work: These slim remotes usually use coin cell batteries. Test their condition, make sure that they are installed in the correct orientation, and check that the contacts inside the remote are not damaged (for example by installing a thicker battery than specified). Test the remote with an IR detector.
    Gain access to the interior (bottom section, not the LCD) of a portable DVD player is usually straightforward requiring the removal of a dozen or so screws from the bottom, and possibly a few on the back or sides. Then the top of the main (non-display) section can be carefully lifted up slightly to check for attached cables. Most of these will be near the hinge, but there may be at least one near the front that goes to the button panel. Disconnect this to allow the top to be flipped up fully. The backlight inverter is located in the LCD section. Removing the bezel will require taking out several screws, possibly hidden behind decorative plastic or rubber plugs. Also see the section: Toshiba SD-KP19 portable DVD player. CAUTION: Everything is tightly packed and tiny in these things, especially in the smaller ones. Go slow and don't force anything. Some case screws may be of differing lengths. Make a diagram to note which go where. Use the proper size screwdriver and apply adequate force to minimize screw head damage. On some Toshiba models, there seems to be at least one screw that is locked into place with more sealer than normal and requires special care to remove without chewing up the head (which then requires drilling it out).  

    General System Problems

    CD player is totally dead

    Check input power, power cord, fuse, power supply components. Locate the outputs of the power transformer and trace them to the rectifiers and associated filter capacitors and regulators. While the actual voltages will probably not be marked, most of the power in a CD player will be typically between +15 and -15 VDC. Sometimes, the voltage ratings of the filter capacitors and/or regulators will provide clues as to correct power supply outputs. Don't forget the obvious of the line cord, line fuse (if present), and power switch - or outlet. Most component CD players use linear power supplies so troubleshooting is straightforward.
    Portables CD players and CDROM drives often use DC-DC converters to produce the various voltages required, and these are much more difficult to troubleshoot even with a complete service manual. Doing anything other than checking for shorted or open components is virtually impossible without an accurate schematic. If an incorrect power adapter was used (or this happened when you plugged or unplugged the power connector of a CDROM drive with power on - a no-no), then major damage can result despite the various types of protective measures taken in the design. However, check for the obvious - a blown fuse on the mainboard near the power connector. These may be picofuses(tm) which look like little green resistors, IC Protectors which look like tiny transistors with only 2 legs, or something else marked F, ICP, etc. You might get lucky. I inherited a Sony Discman from a guy who thought he would save a few bucks and make an adapter cord to use it in his car. Not only was the 12-15 volts from the car battery too high but he got it backwards! Blew the DC-DC converter transistor in two despite the built in reverse voltage protection and fried the microcontroller. Needless to say, the player was a loss but the cigarette lighter fuse was happy as a clam! Moral: those voltage, current, and polarity ratings marked on portable equipment are there for a reason. Voltage rating should not be exceeded, though using a slightly lower voltage adapter will probably cause no harm though performance may suffer. The current rating of the adapter should be at least equal to the printed rating. The polarity, of course, must be correct. If connected backwards with a current limited adapter, there may be no immediate damage depending on the design of the protective circuits. But don't take chances - double check that the polarities match - with a voltmeter if necessary - before you plug it in! Note that even some identically marked adapters put out widely different open circuit voltages. If the unloaded voltage reading is more than 25-30% higher than the marked value, I would be cautious about using the adapter without confirmation that it is acceptable for your player. Needless to say, if the player behaves in any strange or unexpected manner with a new adapter, if any part gets unusually warm, or if there is any unusual odor, unplug it immediately and attempt to identify the cause of the problem. See the document: Audio Equipment and Other Miscellaneous Stuff for more info on linear power supplies. See the document Small Switchmode Power Supplies for more info on DC-DC convertors.

    CD player is operational but there is no display or partial display

    Where the display is very dim or totally out, suspect one or more burned out bulbs for the backlight. Sometimes the display uses miniature incandescent lamps and these burn out. Usually, alternatives to the high priced exact replacement bulbs can be located. Test the bulbs with an ohmmeter. Measure the voltage across the light bulb connections and then replace the bulb with one of about 25-50% higher voltage. These may not be quite as bright but should last forever.
    If the light bulbs are not at fault or there are no light bulbs, then check for power to the display including bad connections or connectors that need to be reseated. There could also be a power supply (e.g., missing voltage to the filament or segments for a vacuum fluorescent display) or driver problem. If only portions of the display are bad - some segments on multiple digits, for example, check for bad connections to the driver chip. The displays are usually multiplexed meaning that a single output of the driver chip actually is used for the same segment in multiple digits or even apparently unrelated words or icons. Thus, a single failure can result in strange display behavior. If no bad connections are found, the driver chip or actual display could be at fault. Since the player works otherwise, unless you are a purist, it make sense to just leave it alone. In the case of a portable or car CD that uses a 'zebra stripe' type rubber compression connector, cleaning the rubber piece, display, and circuit board with alcohol and reinstalling may solve the problem. If it uses a glued on printed flex cable, DO NOT attempt to remove it. Take extreme care when working on such equipment as it is virtually impossible to repair a cable of this type should it tear or pull free.

    CD player ignores you

    Symptoms are that the display comes up normal when power is turned on but all (or certain) commands are ignored.
    This could mean several things:
    • Front panel problem - one or more buttons are not responding. Reseat internal cables, clean or replace offending push button switches. If your CD player has a remote control, see if it operates correctly.
    • Reset failure - the player has failed to reset properly and is not ready for user input. Try pulling the plug for a couple of minutes to see if it will reset. Check power supply voltages, clean and reseat internal connectors.
    • Controller and/or driver electronics for the affected functions are defective. Check power supply voltages, reseat internal connectors.
    For all but the first one, a service manual will probably be needed to proceed further if the problem is not with a bad power supply or bad connections.

    Drawer does not open or close

    If the drawer doesn't open when the front panel button is pressed, listen for motor attempting to open the drawer. If you hear it whirring but nothing happens, check for an oily/loose belt or other mechanical fault like a gear loose on the motor shaft or a slipping rubber wheel. Such a gear is probably split and a replacement will be needed. Rubber parts may be cleaned for a temporary repair but replacement will be needed eventually.
    If there is no attempt, motor, control chip, or front panel pushbutton (try with the remote if you have one to eliminate this possibility) could be bad. Sony players seem to have a built in timer that triggers the belt to go bad after the warranty runs out. Also see the section on "Small Motors in CD Players". Another slight possibility is that the player has gotten into a "Dealer Antitheft" mode which prevents people from stealing CDs or DVDs from demo units in a store. Consult your user manual or ask the place where you bought it for the key sequence. to reset it.

    Drawer operation is erratic

    You are about to remove your favorite CD but the player beats you to it, closes the drawer, and starts playing it over again. Or, the drawer reverses course halfway out. Or, the drawer motor continues to whir even after the door is fully open or closed and the front panel is then unresponsive.
    This is usually due to dirty contacts on the door position sense switches. There are usually 3 sets of switch contacts associated with the drawer mechanism. If any of these get dirty, worn, or bent out of place, erratic operation can result:
    • Drawer closed sense switch - dirty contacts may result in the drawer motor continuing to whir after the door closes and the front panel may then be unresponsive. Eventually, the drawer may open on its own.
    • Drawer open sense switch - dirty contacts may result in the drawer motor continuing to whir after the door opens and the front panel may then be unresponsive. Eventually, the drawer may close on its own.
    • Drawer pushed sense switch - most CD players allow the user to start play by gently pushing on the drawer which depresses a set of switch contacts. If these are dirty, the result may be the drawer deciding to close on its own or reversing direction in the middle of opening or closing.
    The solution to all these problems is usually to simply locate the offending switches and clean their contacts. These switches contacts are usually not protected from dust, dirt, and grime so that these types of problems are quite common. If the drawer simply doesn't respond to your wishes - sometimes, there may be a bad belt or bad motor.
    • Sometimes, how long the player has been powered will affect the 'stickiness' of the belt - leave it on long enough and the belt will loosen and be too weak to operate the drawer. See the section: Drawer does not open or close.
    • The drawer motor may have a 'dead spot' or be partially shorted. See the chapter: Motors and Spindles.

    Drawer does not close (or open) completely

    This is a symptom that may not be obvious. The drawer may appear to close but a loose or oily belt can prevent the mechanism from completing the close cycle. This can result in erratic behavior since the disc clamping action is often controlled by the movement - sometimes not recognizing disc, sometimes just opening the drawer, or more subtle things like tracking problems, etc. Clean the belt and see if there is any improvement. Belt replacement will be necessary eventually. Check for gummed up lubrication as well.
    If it goes through the motions of closing and then stops short without any further sounds, a gear may have jumped a tooth or broken some. The result is either that the mechanism is now incorrectly timed or not able to complete the operation. Examine the mechanism closely for broken parts. Cycle it manually by turning the appropriate motor pulley or gear to see if the drawer gets hung up or is much more difficult to move at some point. If it continues to make a whirring sound after the drawer stops, there might be some other kind of mechanical damage resulting in an obstruction or really gummed up lubrication not allowing the operation to complete. If you have small kids around, don't overlook the possibility that your CD player is being used as a storage cabinet! A favorite toy, rock, gummy bear, jelly bean, or other organic or inorganic object may have found its way into the CD compartment. Or, perhaps, someone, somehow, managed to lodge a disc inside despite the best efforts of the CD player's designers. (This might happen if it was transported upside-down, for example).

    CD changer jams when selecting or ejecting CDs

    Unfortunately, this is the sort of problem one has to see to be able to make specific recommendations.
    • Check for flabby/oily belts (if any), dirt, or and gummed up lubrication.
    • Double check that it is in good condition mechanically - no chipped gear teeth or broken parts.
    • Gear timing may be messed up (especially if someone worked on the unit previously though I don't know which, if any CD changers, depend on this for proper operation).
    Try to cycle the mechanism manually by turning the appropriate motor shafts.
    • A defective sensor - either a microswitch or opto-interruptor - can result in improper commands being issued to the motors.
    • If movement is weak, erratic, or non-exitent, check for bad connections, defective motors and drivers, and power problems.
    • A logic problem is also possible but not very likely.
    Get a bunch of garbage AOL or MSN (your choice) CDs to experiment with - it should be able to cycle them just fine but the audio may sound weird :-). (Hint: Turn the volume way down!) Then, try to determine exactly what it is trying to do and how it screws up. For auto changers where one disc doesn't come out: (From: Tony (tony@buffnet.net).) Try removing all the CDs from the magazine and inserting the empty magazine into the changer. Now turn on the unit and see if the cd goes back into the magazine. If it does not, look for a reset button on the changer. It will be a tiny hole near the eject button that requires a paper clip or toothpick to be inserted to contact the switch. Try pushing this with the magazine inserted. If you do not see a reset switch on the changer look for one on the face of the radio or, if it is a removable face radio, remove the face and see if there is a switch on the panel behind the face and try that. If all of this does not work, the changer will have to be disassembled for the CD to be removed. If the unit is under warranty, take it back so as not to void your warranty by disassembling the unit.

    CD player or CDROM drive damages CDs

    Thankfully, this sort of problem is not very common - the last thing you want is for your equipment to damage the media!
    First, use a garbage CD and attempt to determine exactly where it is hitting or scraping. That may be enough to identify the culprit. Most of the time, this will be a simple mechanical fault like a broken plastic part causing things to jam, or a bit of that part getting in the way. Or, perhaps, your ace system administrator got just a bit carried away in frustration and stomped on the top of the drive. :) On cartridge type changers, a bad or missing belt or gear timing problem could result in the CD getting hung up or scraping as it is extracted or replaced. In some cases, an electronic failure or improperly adjusted focus servo could result in the lens hitting the CD on the top of its excursion. A lot of newer equipment - especially high-X CDROM drives - is built so cheaply that repair may not be possible or cost effective and replacement is the only viable option.

    Spindle table loose or sticks to clamper upon eject

    When you remove the CD, you may have an added surprise - the platform upon which the CD sits pops off as well, possibly jamming everything. There may also be startup and spindown problems.
    Various models use different techniques to fasten the spindle table to the motor shaft but this is strictly a mechanical problem. Either a set screw has worked loose, adhesive has weakened, or a press fit has come undone. If there is no set screw, a drop of Epoxy may be what is needed. However, height is important to guarantee proper focus range so some care will be needed if there no definite stop. The disc and rotating clamper magnet must be clear of any fixed structures and the correct distance from the optical pickup. Where something irreversible is involved like adhesive, checking the service manual is highly recommended - the specification is usually 0.1 mm accuracy. A loose spindle table may also result in continued spinning upon eject or sluggish or noisy startup or seek since the if the spindle is loose, the motor will not be able to properly control disc speed during speed changes.

    Intermittent or erratic operation

    When a CD player appears to have a mood problem - playing fine sometimes or for only part of a disc or aborting at random times, there can be several possible causes including a dirty lens, dirty or worn interlock switch or bad connections to interlock switch (mainly portables and boomboxes), flex cable with hairline cracks in one or more conductors (or just misrouted and close to a metal part of the chassis!), other bad connections, marginal power supply, defective or extended length disc.
    • Dirty, scratched, or defective CD - confirm that the CD is not the problem. Clean the disc and/or try another one. However, not all CDs are created equal. Both the overall quality of the information layer and plating as well as the amount of lead-in and blank space between music tracks varies. Thus, where some aspect of the CD player's optics or electronics is not perfect - or even variations in the microcontroller's programming - can result in the player not properly dealing with some discs. The use of CD-Rs represents even more variability since they are increasingly written on low cost equipment of questionable quality.
    • Dirty lens - a player that accepts some discs and not others or accepts discs sporadically may simply need its eyeglasses cleaned.
    • Extended length discs - some players will simply not play discs which exceed about 74 minutes (the legal limit for CD playing time) to the end (or possibly at all). Such CDs may be as long as 78 or 80 minutes or more. This means that certain aspects of the CD specifications were compromised. Both mechanical and electronic problems are possible. See the section: Problems with extended length discs.
    • Mechanical - oily, flabby belts preventing full drawer closing or gummed up lubrication on the sled (may fail depending on ambient temperature). For example, if the music gets stuck at about the same time on every disc, then there may be gunk on the end of the sled track preventing the sled from moving any further. This is especially likely if you just purchased a disc with an unusually long playing time - it has nothing to do with the musical tastes of the CD player! (There was this Chinese restaurant where the Chinese cooking grease apparently collected on the unused end portion of the sled track and when they tried to play an extra long CD.....)
    • Bad connections - there are often many little connectors used to get signals and power between the optical deck and main circuit board. These are usually cheaply made and prone to failure. Wiggling and reseating these may cure these problems. There may even be bad solder connections on the pins of connectors or board mounted switches. Slight flexing or just expansion and contraction may result in intermittent shutdown or other problems. These problems are more likely with portables and boomboxes which may get abused. The connectors for any flex cables are particularly prone to developing erratic contact. Where a locking bar is used, pull it up to release the cable; remove, clean, and reinsert the cable; and press the locking bar firmly into place may help. Where there is no lock, gently pull the cable out of the connector, clean, and install. I have seen problems of this type on a couple of CDROM drives - portable and component CD players use the same types of cables.
    • A missing shield between the analog ground and the optical deck can result in all kinds of erratic behavior. If these weird problems started after you had the player apart for some reason, check that you replaced the grounding strap or metal strip and/or didn't accidentally disconnect or break any shield connection on the ribbon cable to the optical deck.
    • Cracks in ribbon cable - The moving and fixed parts of the optical pickup are often joined with a printed flexible cable. Constant flexing may cause one or more of the copper traces to crack. This may show up as an inability to get past a certain point on every disc - the player may shut down or start skipping at around 23 minutes into every CD.
    • Dirty switches - oily film or oxidation may be preventing any of the limit or interlock switches from making reliable contact. If this is the case, the player may stop at random times, fail to accept a disc, close the drawer without your permission, etc. Use contact cleaner and typing paper to clean the contacts. Disassembly may be required for enclosed switches.
    • Power supply or logic problems are also possible but rare. However, if you have a scope, check the power supply outputs for ripple - a filter capacitor may have dried up and lost most of its capacitance.
    • External interference from a powerful local radio station (probably AM but could also be CB or a ham operator), light dimmer, or other source. Sometimes reversing the AC plug, repositioning the equipment, or using higher quality cables may help. Unfortunately, there are often no easy solutions to these sorts of problems. A missing or broken optical deck shield ground (see above) could make the player more susceptible to this.
    • Internal damage (e.g., loose parts) in optical pickup. A partially detached lens in Pioneer type pickups (see the section: Objective lens popped out) or loose grating in Sony pickups can result in all sorts of strange and non-reproducible behavior.
    What we normally see on some Sony pickups like the KSS240 is the grating plate glue breaks loose on one end inside the optics, which allows it to move around. The exact position of this is extremely critical to the proper operation of the cd player. Unfortunately the only way to fix this is to replace the optics and realign it as needed.

    CD player or CDROM drive overheats

    A CD player which becomes noisy or a CDROM drive that fails to recognize discs or reliably read data after a few minutes may have a component that is heating up and changing value.
    Before blaming the CD player, confirm that the ambient temperature is not excessive - CD players may not like to operate in a sauna. High power stereo components surrounding the CD player may elevate its internal temperature enough to cause erratic operation or total failure. CDROM drives sandwiched in between high capacity hard drives (this used to be more of a problem than it is today) may overheat. Assuming your CD player is in an environment which is cool as a cucumber: In general, there should not be much change in behavior from the instant power is applied until the next millennium. There is not much in a CD player or CDROM which runs hot and might change characteristics. However, components do sometimes fail in this manner. Problems of this type need to be diagnosed in much the same way as one would find overheating components in a TV or computer monitor. You will need a can of cold spray ('circuit chiller') and an oscilloscope, if available. Even a hair dryer on the no-heat setting will work in a pinch. You are going to have to try cooling various components to try to determine which one is bad. However, on a unit that dies completely and suddenly after it warms this will not be much fun since you will not have ample opportunity to detect changes in behavior. On a CD player that will play but with tracking problems and/or audio noise, you should be able to monitor the playback quality by simply listening for improvement when you have cooled the flakey part. For a CDROM drive, play an audio disc if possible since this will provide the feedback you need to locate the bad part without (hopefully) it constantly shutting down due to data errors or inability to reliably access the file system. First, I would recommend running with the covers removed and see if that has an effect confirming a thermal problem. Try blowing cool air over the exposed innards if nothing obvious occurs. Where components are mounted on both sides of the circuit board, it may be a bit tricky to get airflow to the bottom without disassembly. Assuming you can set up a situation where the problem occurs, use the cold spray on individual components like the LSI chips - quick burst, wait a few seconds for something to change. Where the unit behaves with the cover off, use a hair dryer instead. Make a funnel out of paper to direct the air flow. You will need to be more patient with this approach. If you have a scope, it would be nice to look at the RF 'eye' pattern during this time and see if it decreases in amplitude and/or quality over the course of an hour. If it does, you may have an overheating problem in the laser diode or its power supply. For unknown reasons, the name 'RF' is often used to denote the raw signal from the pickup. Since it's at a few MHz when the disc is playing, the frequency is in the RF range of the electromagnetic spectrum, but there is no radio transmitter inside a basic CD player! :) If the spindle motor is disconnected, the motor or its driver is faulty, or the disc is prevented from turning at the normal speed, the actual frequency of the RF signal can go down to DC (or at least very low if it's measured after AC-coupled circuits). In fact, before the disc starts rotating, there will still be an "RF" signal at the output of the photodiode array, but its frequency is DC! However, a few CD players DO have an RF modulator for transmitting the audio to a nearby FM radio for wireless operation - that is a totally different use of the term being since it's AFTER the audio circuits.)

    Operation is poor or erratic when cold

    This is somewhat the opposite of overheating and is usually NOT due to a failing part - electronic components generally misbehave when hot, not cold.
    For a system that is not exposed to the elements (e.g., a portable taken from sub-zero outdoors and immediately put to use indoors), the most likely cause is mechanical: Gummed up grease and dirt are stiffer when cold and inhibit motion of the sled and other moving parts until the unit warms up. However, for automotive units and portables - which are not well sealed, condensation can form form on the optics if a cold player is exposed to a humid environment. This may be the case when you get into your car on cold days until the CD player itself warms up to ambient temperature. If a VCR or camcorder detects condensation, it will flash a DEW warning and refuse to do anything to protects itself. For VCRs, this is critical because you could end up with a mess and expensive repair bill if the video tape were to stick to the spinning video head drum. Unfortunately, CD players don't have this feature since nothing catastrophic would happen. A warning would be nice, however! A third possibility is that there are bad connections or dirty contacts in the unit that are affected by temperature resulting in erratic behavior as they expand.
     
     

    Startup Problems

    What is a startup problem?

    Startup problems cover all situations where the player does not successfully read the disc directory. Nearly everything in the optical deck and much of the mainboard electronics needs to be functional to read the directory. Therefore, a single failure in any of a large number of places can prevent successful startup (and subsequent play).
    • On a single play unit, failure of the startup sequence may result in a display of no disc, disc, error; a full calender but no disc info; or it may just open the door and challenge you to provide it with a proper meal.
    • On a changer, failure of the startup sequence will likely result in a similar display but then the unit will move on to the next position in the carousel or cartridge. It will likely remember that it was unsuccessful at loading a disc for each position and eventually give up once all possible discs have been tried.
    Possible causes for startup failure include: defective disc, dirty lens, defective laser or photodiode array, bad focus or tracking actuator or driver, dirty track, lack of or dried up lubrication, dirty or bad limit switches or sensors, defective spindle motor, faulty electronics or control logic, damaged parts, faulty optical alignment or need for servo adjustments, a missing optical deck shield, or outside interference. On the one hand this is a large number of possibilities. The good news is that with such a large number of possibilities, there is a good chance the problem will be minor and inexpensive to fix. Don't overlook the trivial: are you loading the disc correctly? Most CD players want the disc label-side up. However, some, like Pioneer magazine type changers want the label-side down. If you have just acquired the CD player, don't overlook this possibility. On some poorly designed players - or where you are located in proximity to a high power (or possibly not so high power) radio station - outside interference can get into the player via the audio cables or line cord. A light dimmer on the same circuit might also produce interference via the power supply. Once inside, almost any type of behavior is possible. See the section: A HREF="#cdpwlygni">Player won't let you go near it and/or use your favorite lamp for testing procedures.

    Startup sequence

    There will be variations on the exact startup sequence of events depending on the type of player and its design. The result may be a blank display, display of the word 'disc', 'error', --:--, flashing display, etc. In any case, you don't get your music. By understanding the following summary as it applies to your player, you should be able to determine what is going wrong.
    A dirty lens - perhaps not even visibly dirty to your naked eyeball - can result in any number of startup (or other) problems. Therefore, cleaning of the lens should be done before suspecting more obscure mechanical or electronic faults. See the section: General inspection, cleaning, and lubrication. BTW, as hard as it may be to believe, there have been rare instances of the objective lens falling off! Actually, not so rare asn this seems to be a common problem with Pioneer CD players where the pickup is mounted upside-down. So, the lens isn't where it's supposed to be, check for it bouncing around in the bottom of the player! See the section: Objective lens popped out. If this is a new player (at least for you) or has just been moved, check to see if it has a transportation lock to prevent the pickup from bouncing around during shipment. This is common on older units but you may find such a feature on the latest CD players and CDROM drives where a linear or rotary positioner is used to achieve high speed access. The lock migh prevent the sled from moving to the area of the disc directory (and of course, from playing properly). What the CD player should do when a disc is inserted:
    1. Drawer closes (or with portables, lid is closed manually) and CD is clamped to spindle.
    2. Interlock (if present, always in portables) engages. In others, there may be an optical sensor or the optical pickup may act as its own disc sensor assuming a disc is present when it detects reflected light from the disc's reflective information layer.
    3. Pickup resets to starting (index) location toward center of disc usually found with limit switch or optical sensor.
    For the following, refer to the diagram below or the slightly nicer version: CD Player Front-End showing the photodetector organization typical in units with a 'three-beam pickup'. E and F will be absent in units with a 'single-beam pickup', though there may be other segments. The four quadrant photodetector is present in all systems. The front-end circuitry shown is for descriptive purposes only; refer to an actual CD player schematic for details.
                         |<--- Photodiode Array ---->|
                                   +---+---+
       ---------_________ +---+  +-| A | B |-+  +---+
       Track--->          | E |- | +---+---+ | -| F | ________
                          +---+  | | C | D | |  +---+         ---------
                            |    | +---+---+ |    |           Track--->
                      /|    |    |   |   |   |    |
        Focus       / +|----|----+---|---+   |    |    
        Error o---<    |    |    |   |   *   |    |    |\
        (A+D)-(B+C) \ -|----|----|---+-------+    +----|+ \       Tracking
                      \|    |    |   *       |         |    >---o Error
                  FE Amp    +--------------------------|- /       (E-F)
                                 |           |         |/ TE Amp
        * Since the photodiodes  |           |           
          are current sources,   |           |         |\
          the simple junctions   |           +---------|+ \       Data Out
          implement a sum.       |                     |    >---o RF Test Point
                                 +---------------------|- /       (A+B+C+D)
        All Amps: current mode inputs.                 |/ DO Amp
    
    
    The main return beam is detected by the array, ABCD. The tracking beams return to E and F. E is offset slightly off track on one side and F on the other. Average signals from E and F will be equal when centered on track. The following three steps may or may not be performed concurrently:
    1. Laser is turned on and focus search routine is started to position lens at correct vertical position. Once correct focus is achieved, focus servo is activated to maintain it. Focus, which must be accurate to 1 um, operates as follows: The optical path in the pickup includes a cylindrical lens (or this may be a thick beam splitter mirror or astigmatic objective lens) which causes the laser beam spot to be circular when correctly focussed but elliptical otherwise with the major axis of the ellipse being offset 90 degrees depending on whether the lens is too close or too far (e.g., major axis of +45 degrees for too close and -45 degrees for too far). Focus Error = (A+D)-(B+C) = 0 for correct focus since with the circular spot, the outputs of all four quadrants will be equal.
    2. Disc starts spinning up to 500 rpm and Constant Linear Velocity (CLV) servo is activated to maintain correct speed. CLV servo uses a PLL to lock to clock transitions derived from data read off of disc. Data is derived from A+B+C+D. (A buffered version of this signal can be monitored at the 'RF Test Point'.) A partially shorted spindle motor can result in the disc spinning but never quite reaching the required 500 rpm.
    3. Tracking servo is activated to maintain laser beam centered on track. With 'three-beam pickup', 2 additional laser spots are projected onto the disc in front of and behind main beam. These are offset on each side of the track just enough so that Tracking Error = E-F = 0 when centered. With a 'single-beam pickup', similar information is derived using only the main beam since Tracking Error = (A+B)-(C+D) = 0 for correct tracking.
    At this point, data is available for digital processing.
    1. Disc directory is read and displayed.
    2. Unit shuts down awaiting command or goes into play mode depending on how it was activated.
    If any of steps 1 to 7 fail, then the laser is turned off and the machine will display some kind of error no disc message (typically, it may display Error, Disc, or go blank) and return to idle mode, or in the case of a changer, load the next disc and try again.

    More details on the startup sequence

    Usually, the sequence of events is: tray closes, and "tray in" switch is made. This tells the system control micro that it can go ahead and start the TOC read sequence. Next, the sled motor will normally be driven back and forth a small amount to check that the laser is "home". There is a leaf switch that is pressed by the laser assembly to tell the micro that it is home. The system control micro then turns on the laser. At this point, what happens next depends on the player. Usually, the player will start the focus search operation, which is normally a maximum of three full up-down excursions of the lens, before it gives up, which may be because there is no disc in there, or the pickup is faulty, or the laser is not burning, or weak output. If all is well, the laser should obtain focus within one up-down cycle, and the focus servo will lock and produce a focus true signal. This should result in the spindle and tracking servos being turned on, and the disc should spin up, whilst the tracking servo attempts to lock on the data that should now be streaming off the disc. Once the tracking servo has locked and good data is coming off the disc, the spindle servo will be fine tuned to correct the rotational speed of the disc, and proper data reading will then take place and the disc's TOC will be read. When this has happened successfully, the spindle motor will be electronically braked, and the laser, focus and tracking servos will all be turned off.
    Some players deviate from this sequence once the laser has been turned on, and just go ahead and spin up the disc to some coarsely maintained speed, whilst focus seek and tracking seek are taking place. Once they have happened successfully, and their servos are locked, the spindle servo will be locked. This sequence of events results in a quicker TOC read from a standing start. Some other players don't give up immediately after 3 focus tries. Instead, they rotate the disc just a bit, and try again, in case there was a jammy fingerprint on the disc right above the lens. This may repeat several times, before the player gives up. The key to figuring what's going wrong on your player, will likely be observation. Try watching carefully how the deck responds when there is no disc inserted. If it seems totally inert, try opening and closing the tray a number of times to see if it ever does spring to life, which might indicate a problem with the tray closed sense switch ( the tray motor might also be trying to still run, even after the tray is fully in ). If it always does something, then try again with a disc in. Try to get it into a position where you can see what the laser is doing under the disc. If it does run up OK, watch and note the sequence of events, then try opening and closing again, until it doesn't work, and see what changed. Also, vice versa. If you see the laser shuffle take place when it does work OK, but not, or in a different way, when it doesn't work, this might indicate an iffy laser home switch. If nothing appears to fundamentally change up to the point where the disc should spin up, between working or not, then you could have an intermittently faulty, or very marginal laser. The Philips ones certainly do fail, and mostly come as a complete deck assembly, and are not hugely expensive. All of this assumes that it is not one of the early Philips radial arm decks, of course...

    Procedure for validating the startup sequence

    The following procedure is used when the disc is not recognized but the drawer closes completely.
    First, double check the drawer closing/opening mechanism. Without exception, Sony CD players which have belts need them cleaned and eventually replaced. If the drawer does not close completely, then the disc may not be clamped properly or other erratic problems may occur. Once you have verified that this is ok, you need to determine that the lens is clean. In general, the lens should look shiny with a blue tinge. Any scum or crud can degrade performance. You may have to remove part of the clamping mechanism to be able to see the lens. If it is not perfectly shiny, clean it using the procedures in the section: General inspection, cleaning, and lubrication. Assuming that this does not improve the situation, the next step is to verify that the pickup has reset itself to the inner (center) track of the disc. If necessary manually move the pickup away from the center by turning the appropriate pulley or gear, or in the case of a linear actuator or rotary positioner (no gears or belts), just push the pickup gently and observe the behavior when a disc is loaded. If you are not able to move the pickup smoothly from one stop to the other, make sure any shipping lock is disengaged! The pickup should move smoothly toward the center, usually tripping a limit switch and stopping. If there is no movement or movement is jerky or the pickup gets stuck at some point, then lubrication may be needed or the motor or drive circuitry may be faulty. Also, check for broken or damaged gear teeth, a slipping belt, and misaligned or damaged tracks. Measure the voltage on the motor that moves the pickup. If there is none or it is very low (under a volt or so), then there is a problem with the motor, its driver, or the system controller. Determine if the machine attempts to focus. On portables, it is sufficient to defeat the door interlock to get the operations associated with reading of the disc directory to begin (you may need to press play - this is model dependent). In some component CD players, a disc actually has to be present to block an optical sensor. You should see the lens moving up and down (at least one of these directions will have smooth movement) once or twice about 2 mm. If a disc is in place, then the lens should quickly stop at the appropriate focus position. Admittedly, observing the lens may be difficult or impossible with the disc in place. Dentists are probably good at this! If the focus action is identical whether a disc is in place or not - i.e., it keeps up the search pattern and then gives up - verify that the laser is being powered. In most cases, you should be able to see a tiny spot of red appearing light when the lens is viewed from an oblique angle during the focus search. From a safe distance of at least six inches and 45 degrees or more off to one side, you should be able to see this dim red light in a darkened room while the unit is attempting to focus. If you see this, you can assume that the laser is being powered though it is not a sure test for an actual IR laser beam or proper optical power output. In most cases, however, the red light indicates that the laser is working. If there is no dot of red light, then either the laser diode is bad, it is not being powered, or you are not looking from the correct angle. An IR detector would confirm at least that there is an IR emission which in most cases means the laser is working (though possibly not at the proper power level):
    • You can purchase an inexpensive IR detector card from an electronics distributor.
    • A tester can be constructed using a photodiode, a few resistors, a general purpose small signal transistor, and an LED running off a 9 V battery. See the section: IR detector circuit. This will useful for testing IR remote controls and other IR emitters as well.
    • If you have a modern camcorder (one with a CCD pickup, not a tube), it may be sensitive to IR as well but using one to test a CD laser would be pretty clunky to say the least (you would probably need to grow an extra arm or two). However, viewing the beam pattern projected on a white sheet of paper will enable the gross alignment to be checked easily - it should be fairly symmetric and centered above the lens.
    If there is no IR emission while the lens is moving up and down, see the section: Testing the laser diode while in the player for more info on determining if this is a laser diode or driver problem. If the lens is hitting the disc at the top of its excursion, there is a possibility that the spindle table has been pushed too far down - by something falling on it, for example. (A bent shaft and wobbly spindle is also a possibility in this case.) Such an occurrence is much more likely to have happened to a top loading boombox or protable than a drawer loading machine. (A friend of mine used to pound on his Sony boombox when it would not cooperate and this didn't help matters.) While hitting the disc with the spindle table set at the correct height is not impossible on some players, it is unlikely. (On most lenses, a ring around the outside of the lens itself prevents the critical central area from actually contacting the disc so accidental contact does not usually damage the lens but may scratch the disc. However, I have a portable where even this was not enough - the lens was seriously scratched somehow). Similarly, if the spindle is too high, the lens may not be able to reach up to the proper focus position. On a player with the height adjusted properly, there is usually about 2 mm between the laser shroud and the bottom of the disc. The spindle height is not super-critical but if it is way off, proper focus cannot be established. See the section: Spindle motor replacement. Incorrectly adjusted focus offset or gain may result in the lens search pattern being too high or too low as well. Once focus is established (and sometimes concurrent with this operation), the spindle should begin to turn and quickly reach 500 rpm. The speed may be ramped up or controlled in some other search pattern since there is no speed feedback until the data coming off of the disc is available. A partially shorted motor will prevent the spindle from reaching 500 rpm even though the disc will spin. Check the voltage on the spindle motor when it starts the disc spinning. It should reach 2 volts or more. If less than this but not zero, a partially shorted motor or weak driver is likely. If zero at all times then there may be a bad driver or the machine may not realize that focus was established and is not issuing the spindle motor start command. The required speed of 500 rpm - just over 8 revolutions per second - can be estimated by using a disc with a dramatic label or putting a piece of tape on the side of the disc that is visible and watching it spin. CAUTION: Only use sticky tape on a garbage CD as removing it may pull the information right off the disc (especially CD-R/RW). Note that a dirty lens can sometimes result in symptoms similar to a bad spindle motor so cleaning the lens should always be the first step when servicing a CD player. I almost learned this the hard way. Once the disc reaches the correct speed, the speed control (Constant Linear Velocity, CLV) and tracking servos will be activated (or the tracking servo may actually have been active all along) and directory data will be read off of the disc. Either of these could be faulty and/or misadjusted making it impossible to access the disc directory. During the time that the disc is spinning and the player is attempting to read the disc directory, listen for that 'gritty' sound that CD players make during normal operation. It is a byproduct of the focus and tracking servos constantly adjusting lens position - the rapid movements of the lens produce audible sound like a loudspeaker - and its presence is a good indication that (1) the laser is working and (2) focus is being maintained. On certain CD players, for example many Pioneer models, there is a TEST mode which enables many of the individual functions such as focus and tracking that are normally automatic to be manually enabled. This is a very useful aid in diagnosis and in adjusting a machine from an unknown state as would be the case if someone else twiddled every internal adjustment they could find! See the section: Pioneer PD/M series test mode.

    Disc spins in wrong direction or overspeeds and is never recognized

    The CD should always spin clockwise as viewed from the label side of the CD. This is usually the top but for some players you load the CD upside-down (e.g. Pioneer magazine type changers). If the CD should consistently start spinning counterclockwise and continue for more than a fraction of a revolution, or should the CD ever spin at a much faster rate than normal - as though it is about to take off, there may be a serious problem with the optical pickup, spindle servo, or control logic. However, behavior of this type could simply be the result of any of a number of minor faults which you can diagnose and repair including a dirty lens, the disc being loaded upside-down, or the internal adjustments being messed up due to someone violating rule #1 - never wildly tweak any internal adjustments!
    First confirm that the disc is loaded correctly and that the lens is clean. Check for bad connections and cracks in any printed flexible cables to the optical deck as well. Clean and reseat connectors just to be sure. Where a brushless DC type spindle motor (rather than a PM motor) is used, even a bad connection to the motor could result in strange behavior due to a missing phase or feedback signal. If this does not help, attempt to perform a servo system adjustment. If you have a service manual, by all means follow it! If not, see the chapter: "Servo Systems and CD Player Adjustments". If it is a Pioneer CD player or changer, see the section: Pioneer PD/M series servo adjustment procedure (this may also apply to other non-Pioneer models with only minor changes).
     
    Two faults I've seen: The upper bushing in the spindle motor is worn, or the commutator brushes are bad. A worn upper bushing leads to disc wobble. The spindle motor servo can't get a good feedback signal from the disc and it starts to hunt. Similarly, if the brushes are worn and making poor contact, the motor does not respond properly to the drive and the servo starts to send full drive signals to the motor to get it going, only to end up with the disc spinning flat out. In the CDs I've had with these spindle motor related problems, the added noise is this on and off drive torque hitting the motor.

    Pickup attempts to reset past inner track

    Sled motor doesn't stop at the inner track but keeps clicking, clunking, or whirring until the controller gives up and displays an error.
    This may be due to a dirty, worn, or gummed up limit switch, bad connections, bad mechanical alignment or broken parts, or logic problems. Most limit switches are mechanical and easily checked with a multimeter. Those that use exposed contacts can be cleaned and burnished; sealed switches found to be erratic should be replaced though spraying inside though any openings may help. I have disassembled and cleaned similar type switches (they snapped apart) but it is not fun. Make sure the limit switch actually gets tripped when the sled reaches the area of the innermost track. Check for bad connections between the switch and the controller. Logic problems may be difficult or impossible to locate even with schematics. However, you might get lucky as was the case with a CDROM drive with a bad 74LS04 in the drawer switch interface!

    Player won't let you go near it and/or use your favorite lamp

    Symptoms may include a player where the audio becomes noisy or even stops completely or stuttering or skipping occurs, if you touch or go near it!
    Note that there is an entire chapter: "Tracking (Seek and Play) Problems". However, since a possible cause of this sort of behavior is more general in nature and can affect many different aspects of CD player operation, these faults are described separately.
    • One area that may be overlooked as a cause is the shielding of the pickup low level signal cable and any metal parts of the optical deck. These should all be connected to analog ground of the electronics board. If this is missing or broken, there can be all kinds of strange symptoms. If you have recently disassembled the unit and it is now behaving in this manner, this is a very slikely - easy to fix - possibility. Check for a missing ground strap, jumper, or clip. Hint: it has probably fallen under your workbench!
    • External interference from a high power (or not so high power) radio station or even a light dimmer on the same circuit may make its way into the electronics and produce all sorts of strange behavior. On some poorly designed players - or where you are located in proximity to a high power (or possibly not so high power) radio station - outside interference can get into the player via the audio cables or line cord. A light dimmer on the same circuit might also produce interference via the power supply. Once inside, almost any type of behavior is possible. If your problems seem to depend on the time of day, check out this possibility by relocating the CD player and seeing if the behavior changes substantially. Disconnect the audio cables and see if it now displays the disc directory and appears to play properly - try headphones if possible. It may be difficult to eliminate the effects of this interference without moving the radio station or not using your favorite lamp. However, relocating the CD player or even just its cables and/or plugging it into a different outlet may help. Fortunately, these sorts of problems are not that common.  

    Tracking (Seek and Play) Problems

    Description of seek and play problems

    The term 'seek' refers to the operations needed to move the pickup and locate the exact position (time) on the disc to begin or continue play (during programmed track selection). The term 'play' is self explanatory and refers to the condition of reading off data continuously while outputting audio signals to the headphones or amplifier. Somewhat in between are the actions performed during audible search forward or backward.
    When playing at normal speed (e.g., 1X for music), the fine tracking servo maintains the laser beam centered on the track (pits of the information layer) of the CD while the coarse tracking servo moves the entire optical pickup as needed to keep the tracking error within well defined limits. See the section: Servo systems. Failures or marginal performance of any of these systems can result in audio noise, skipping, sticking, or failure of seek and search operations. The following types of problems are common:
    • Seek failure resulting in the inability to locate the starting track.
    • Short or long distance skipping backward or forwards or sticking.
    • Occasional or repetitive noise, clicking, or muting.
    A dirty or badly scratched or warped disc, a dirty lens, damage to the lens suspension or a smashed lens cover, a defective or improperly set AC adapter (voltage too high, too low, inadequate current capacity, poor regulation, or too much ripple), weak batteries or wrong type of batteries (NiCds may not work in a player designed for normal 1.5 V AAs), or a missing optical deck shield ground connection can result in similar symptoms as well. Thus, if you experience any of the problems discussed in the next few sections, first confirm that the disc is not dirty, scratched, smudged, warped, or otherwise defective - inspect and clean it if necessary and/or try a different one. Check the AC adapter or batteries. If no problems are found, manually clean the lens. If you recently had the player apart, check the grounding of the optical deck. The importance of doing these simple things first cannot be overemphasized as many apparently unrelated problems can be caused by a bad disc, dirty lens, or bad power. Then, check for obvious mechanical faults like gummed up lubrication or a worn spindle bearing. Only after these efforts do not solve your problem or at least identify the cause, should you consider adjusting any of the servo systems.

    The seek process

    Proper readout of the digital audio or data on a CD depends on the proper functioning of the focus, and tracking servos and the system controller. The basic operation of these has been confirmed by successful reading of the disc directory. However, additional logic and drive electronics are called into action to actually seek to a particular track (even if it is the first) and switch to play mode.
    When initiating play or seeking to a particular track, the player must go through the following 4 steps (exact details may vary depending on the design of your particular CD player):
    1. The sled motor moves the pickup to the estimated position of the selected track based on its time code. For long jumps, this may be done partially open-loop. However, at some point - possibly from the start - the time code on the CD will be sampled periodically to determine instantaneous sled/pickup position. To access the time code, tracking must be stable for long enough to read 1/75th of a second of data (requiring tracking lock for up to 1/37th of a second if it just missed the start of a data block). This is possible even when the sled is moving since the fine tracking servo can backtrack to maintain tracking lock.
    2. Once in the vicinity of the selected track, the sled is moved in small increments forward (and backwards if it overshoots) until the lens is within the 'acceptance window' of the fine tracking servo. Again, the time code is read and a direction and distance is selected by comparing it with the desired destination. On many players, you can actually hear this iterative process (by listening to the player - not the speakers) when using the >>| or |<< select keys.
    3. With the fine tracking servo is engaged, the position of the lens is then jogged to home in on the exact time of the start of the track usually without moving the sled. Once it is within, say 25 frames prior to the desired starting location (1/3 second), it will just start playing but with the sound muted. Sometimes, it may be possible to have stopped at just the wrong position just out of range of where it wants to be (using the fine tracking servo alone) so that the sled would then move based on the normal tracking error criteria - exceeding a threshold (since the fine tracking locked).
    4. Once the exact starting point is located, audio is unmuted and normal play begins.
    Though all of these steps require the optical pickup to be operational, they each depend on different parts of the servo circuits - a failure could result in one of these steps not operating properly. Audible search maintains the fine tracking lock but jogs the lens to move forward or backward. Audio is unmuted for a fraction of a second and then this process repeats. Thus, (3) and (4) are repeated (with the jog direction determined by which button is pressed) continuously. Issuing a PAUSE command results in the fine tracking servo jogging the lens to maintain a constant position (time code). While playing, searching, seeking, or in pause, focus must be maintained continuously despite spindle runout, a moderately warped disc, and minor bumps or vibration. Thus if focus adjustment is marginal, loss of focus may complicate your diagnosis of tracking problems - make sure focus is solid before moving on to tracking or rotation problems.

    Diagnosis of erratic play

    If you have a suitable oscilloscope, the following approach may help to narrow down and correct the problem. If not, you can use the alternative techniques outlined in the sections relevant to your symptoms. See the section: The CD player 'eye' pattern for a description of typical test points and signals.
    Start with the RF test point. It probably should be about 1 V p-p. (However, the exact value will depend on model.) This should be the eye pattern. Determine if it is weak, noisy, or erratic. If you can get it somewhat stable, try tweaking the various offsets (RF, focus, tracking) just a bit to optimize its appearance. The waveform should look approximately like the diagram in the the section: The CD player 'eye' pattern. Adjustment of the focus controls will probably affect mostly the amplitude of the eye pattern and the amount of noise; adjusting tracking may also affect side-to-side jitter. If the eye pattern is erratic, look at the focus error and tracking error test points. These should look like high frequency random noise but not be jumping or changing erratically. The DC offset of the tracking error should increase gradually as the lens moves to follow the spiral track and then jump back once the sled motor kicks in to re-center the pickup. Use the buttons that move the sled to see if the rotation speed is correct at the beginning, middle, and end of a disc. (500-350-200 rpm). If it has trouble at the beginning, a bad spindle motor or driver is possible; if it has trouble at the end of the disc, a bad driver is possible. Adjustment of the PLL or VCO pot may correct for these types of problems. Check the eye pattern at the start and end of a long disc as well.

    Seek operations take too long or fail to complete

    This means that attempting to seek to a particular music track results in this never completing or going to the wrong place. Alternatively, even pressing the search forward or backward buttons may result in the failure to go where directed. The player may abort the disc and stop or (in the case of a changer) go on to the next one. Even the first track may never be played. However, it is assumed that the disc directory is read reliably.
    Common causes: dirty lens, bad disc, tracking or CLV PLL adjustments needed, transportation lock engaged, mechanical problems with pickup movement, faulty sled motor or drive IC, faulty control logic, bad flex cable.
    • If your CD player has a 'transport lock' screw, check that it is in the 'operate' position.
    • Inspect the disc for badly scratched or smudged areas and other defects or try another one. Clean the lens.
    • Eliminate the possibility of mechanical problems - see the section: Testing the sled for mechanical problems.
    • Check for a printed flex cable that has hairline cracks in one or more traces. As the pickup moves past a certain location, a critical connection may open up resulting in this behavior. Such a cause is more likely if the player aborts without warning during a seek or search.
    If none of this uncovers the problem, there may be sled motor driver, logic, controller, or other electronic problems.

    Search, seek, or play starts correctly, then loses time or position

    You may select music track 5, the player goes there quickly, starts to play but immediately jumps to another location forward or backwards or resets to the start of the disc. Or, if play is started at any location, instead of playing forward as would be expected, the numbers in the display count down.
    Common causes include a defective disc, dirty lens, stuck button, need to adjust coarse tracking offset or tracking balance, bad sled motor drive IC, or faulty control logic.
    • First, try a different CD to make sure it is not defective. Or, try different locations on the same CD as the CD would likely not be defective over its entire surface.
    • A dirty lens is always possible. Clean it.
    • This may be a problem with coarse tracking offset or tracking balance. See the section: Adjustment procedure for noise or skipping.
    • To eliminate the possibility of a stuck button, it may be possible to operate the player with the relevant part of the front panel control unplugged using the remote control (if it has one) or the 'press the drawer' method of starting play. If either of these results in the disc playing normally, then a stuck or dirty button is likely. This will most likely require the disassembly and cleaning or replacement of the affected push button switch.
    • It is possible that the sled motor driver IC or its logic is bad: when the tracking servo is closed, its output is highly unbalanced due to an internal failure. Unless you want to take a shot in the dark and replace the chip, further troubleshooting of this problem will likely require a service manual. However, I have lucked out when the driver IC on a Pioneer CD player was running excessive hot - replacing it cured this problem.

    Types of skipping problems

    The general behavior will usually fall into one of the following categories:
    1. It gets stuck and repeats a fraction of a second (1 rotation).
    2. It gets stuck, jumps back, and repeats a few seconds.
    3. It starts having repetitive noise at the disc rotation rate - about 200-500 rpm (3-8 Hz).
    4. It starts skipping continously or every few seconds either forward or backward.
    Assuming your CD is clean and undamaged (check with different CDs), then this sounds like a mechanical problem - proabably dirt in the optical pickup worm screw or lack of or dried up lubrication. It could also be a worn spindle bearing or an electronic adjustment. If problems are most severe at the start of a disc, then spindle motor problems or PLL adjustments are likely possibilities. If problems are most severe near the end of a disc, spindle bearing, track lubrication, and PLL adjustments are likely possibilities. The next few sections deal with these types of problems in detail.

    Short distance skipping

    This means jumping forward or backward by a fraction of a second. It may occur occasionally or may appear as though the pickup is bouncing across the disc.
    Common causes include dirty lens, dirty or damaged disc, need to adjust fine tracking offset/gain or tracking balance, weak laser or other defective part in the optical pickup. First, inspect the disc for badly scratched or smudged areas and other defects or try another one. Clean the lens. See the chapters: "Servo Systems and CD Player Adjustments" and "Testing of Optical Pickup Assemblies".

    Playback gets stuck (rapid repeat)

    This means repeating the same track or a small number of tracks (meaning disc rotations, in this case). The effect is somewhat like a 'broken record' with an LP but at a much faster rate - 3 to 8 repeats per second when repeating only a single track.
    The most common underlying cause is a damaged or dirty disc. However, if the tracking (and sometimes focus as well) servos are not properly adjusted, the CD player may exhibit excessive sensitivity to disc problems. If the focus or tracking gain is set too high or the offsets/balance are not centered, slight disc imperfections, scratches, or dirt may result in this set of symptoms. See the chapter: "Servo Systems and CD Player Adjustments".

    Occasional long distance skipping or repeating

    Usually, several seconds of music will play without any trouble and then there will be a skip forward or backwards by a few seconds or longer. In the latter case, the net effect may be to constantly repeat a section of the CD. Make sure you do not have any repeat modes enabled!
    Common causes include a dirty lens; dirt, foreign materials, or lack of lubrication in pickup drive; defective disc (surface defects, dirt, or fingerprints); mechanical damage causing mechanism to bind.
    • First, inspect the disc for badly scratched or smudged areas and other defects or try another one. Clean the lens.
    • A mechanical fault is quite likely. These symptoms generally indicate that the coarse tracking servo is unable to properly move the pickup easily as it should - it is getting stuck and then either jumping back once the error is too great or breaking free and moving forward in spurts. Common problems include gummed up lubrication, dirt or other debris on the tracks or gears, damaged gear teeth, bad belt slipping, misaligned parts. See the section: Testing the sled for mechanical problems. Note that some CD player models had problems like this due to poor design. For example, the Sony D2 Diskman would develop problems like this requiring reduction adjustment to a spring and wiper to reduce the force required to move the sled.
    There could also be a problem in the electronics but first eliminate the possibilities listed above

    Player gets stuck at approximately same time on multiple discs

    Common causes: transportation lock engaged, gummed up lubrication on pickup tracks or worm gear, other mechanical problems like an obstruction or errant wire getting in the way. A flex cable with a hairline crack in one or more conductors might also cause this symptom.
    • Make sure the transportation lock, if any, is disengaged.
    • Carefully inspect the sled gears and tracks for dirt and gummed up lubrication. If the player has been in commercial service always playing the same CD or set of CDs and now you are attempting to one that is someone longer, this may happen as the end of the track is unused and dirt collects at the boundary.
    • Check for mechanical damage and obstructions like wires or cables.
    • If you are attempting to play a CD which is longer than 74 minutes, the player may not be capable of accessing the last part of the CD. It might either abort or get stuck and keep repeating a fraction of a second or several seconds. See the section: Problems with extended length discs.
    • If play deteriorates gradually as the pickup moves toward the outer edge of the disc, the CLV servo may need adjustment or the spindle motor may be defective.

    Various tracking problems on portions of discs

    This means that one part of the disc (start or end) plays properly (or at least with less problems) than another. For example, the disc may play flawlessly until approximately the 30 minute point and then develop noise, skipping, or other similar problems.
    Common causes: defective disc, faulty spindle motor, misalignment of spindle table and sled track, need for CLV adjustment.
    • Try some other discs to eliminate a defective disc as a possibility.
    • If the problem is most severe at the start if the disc, the spindle motor may have trouble reaching the required 500 rpm rotation rate consistently. See the chapter: "Motors and Spindles".
    • The spindle table and track on which the sled moves may be misaligned. This is especially likely if the player was dropped or otherwise abused. See the section: Testing the sled for mechanical problems.
    • An adjustment of the servo that controls the Constant Linear Velocity (CLV) drive to the spindle motor may be needed. See the chapter: "Servo Systems and CD Player Adjustments".

    Repetitive noise at disc rotation rate

    Common causes: dirty lens, bent spindle, excessive runout (wear) of spindle bearing, loose spindle, foreign material on disc table, disc not firmly clamped, warped disc, need to adjust focus or fine tracking offset/gain, weak laser.
    • First, inspect the disc for badly scratched or smudged areas and other defects or try another one.
    • Clean the lens.
    • Check for a loose spindle (sometimes there is a set screw that needs to be tightened or some adhesive may have broken free.
    • Make sure there is no dirt or other foreign matter on the spindle table that could cause the disc to seat improperly.
    • Observe the disc as it spins. Is the edge moving up and down by more than a total of about 1 mm? If so, the disc may be excessively warped, or possibly the spindle bearing is worn resulting is unacceptable runout, or (unlikely unless the player was thrown off a cliff) the spindle is bent. The focus and fine tracking servos may be incapable of correcting such a large wobble. This could also be due to a disc clamper that is not working properly - the drawer closing mechanism may not be quite completing its cycle or possibly the magnet may have weakened. Gently press down on the rotating part of the clamper while playing - if this reduces or clears up the playback and/or if you can feel the disc seat better, then this is a possibility.
    • If the problem developed gradually and has been getting worse, than a worn spindle bearing is a distinct possibility. Adjustment of focus and fine tracking offset (or possibly gain but usually less critical) may help.
    • Alternatively, focus or fine tracking offset (or possibly gain but usually less critical) may simply have drifted a bit and adjustment is all that is needed.
    • A weak laser may also result in these symptoms but do not attempt to adjust laser power until other possibilities have been investigated fully.

    Marginal play - internal controls are not marked

    This may mean that some discs play properly while others have problems with skipping, sticking, repeating, or noise in the audio. Unfortunately, many players, particularly portables and CDROM drives, do not have adjustments that are labeled. (For some portables, you may need the special test discs described in the section: Useful ways to mangle CDs.
    Since one possible cause of these types of problems (after the lens and mechanics have been ruled out) are servo adjustments. See the chapter: "Servo Systems and CD Player Adjustments". Then, I would mark the precise positions of all the controls. While playing a disc that works but has minor skipping, noise, or similar problems, carefully try adjusting each one on either side of its current position to see if that will help. Then if this helps, change to progressively more problematic discs to see if you can home in on the optimal settings. By observing the behavior as you tweak each control, it may be possible to determine their functions.

    Testing the sled for mechanical problems

    Binding or obstructions would be indicated by any long distance skipping, jumping, repeating, or failure to seek or search past some location (time) on multiple discs. Defective or erratic limit switches may result in jamming or overrun at start or end of disc or unreliable reset during startup.
    Check for free movement of the optical pickup sled on its tracks or bearings. Manually rotate the appropriate motor or gear or in the case of a voice coil (linear or rotary) positioner, gently move the pickup back and forth throughout its range. There should be no sticky positions or places where movement is noticeably more difficult. If there are, inspect for mechanical problems like broken or damaged gear teeth, dirt or other material that should not be there, and gummed up lubrication - or that you didn't forget to release the transportation locking device! I've even heard of bits of plastic being found in between gear teeth - probably from the original manufacturing process - that didn't bother anything at first. Damaged parts will need to be replaced (or repaired - sometimes a fine file, Xacto knife, or dental pick will work wonders but don't count on it). Otherwise, cleaning and lubrication may be all that is needed. Remove the dirt and the old gummed up lubricants and lubricate the tracks and/or gears using the proper oil or grease. (See the section: Lubrication of CD players. Inspect the alignment of the track with respect to the spindle motor. If the spindle motor shaft is not at an exact right angle to the sled movement, tracking may be affected on certain portions of the disc. One best way to this is to clamp a disc onto the spindle table and then manually move the sled from end-to-end measuring the distance between the pickup and disc at both extremes. It should be equal. A variation of more than a fraction of a mm can cause tracking problems. If these tests come up negative, check out the pickup (sled) motor for defects such as a shorted or open winding, dead spot, partially shorted commutator, or dry or worn bearings. See the section: Testing of motors. As a double check, disconnect the motor from its driving circuit (extremely important!). Use a 3 V battery in series with a 25 to 50 ohm variable resistor or a variable low voltage (e.g., 0 to 5 V) DC power supply to drive the motor. Start at the highest resistance or lowest voltage and adjust it until the sled just starts moving. Run it from end-to-end in both direction. The sled speed should be fairly uniform with no sticking or binding. There should not be any excessive noise or grinding sounds. If this is not the case, there are still problems with motor or sled mechanism. Another check would be to substitute a 15 ohm 1 W resistor for the motor and see if a few volts appears across this when the player should be resetting since this usually involves moving the sled to the inner limit. If there is none, the driver may be blown or lack power, or the controller is not providing the proper commands. In addition, check the proper functioning of any limit switches that are present on the optical deck. There will almost always be one for the inner (reset - startup) track and there may be one for the outer track (end-of-disk) as well. Run the pickup manually or using the battery (see above) to both ends without forcing and check for reliable operation of the switch contacts.    

    Miscellaneous Problems

    Audio problems - muting, noise, or distortion

    Silly me, what other kinds of problems are we talking about? OK, I should have said: audio signal chain problems. The player appears to be working fine (the disc is spinning; the time is incrementing correctly; seek, search, and play operations behave normally) but there is either total silence, noise, or distortion, on one or both channels. However, also see the section: Types of skipping problems and those that follow since these sorts of audio symptoms may be mistaken for those caused by problems with servo alignment, the optical pickup, or front-end electronics. There is a distinct boundary between the digital section where audio information is encoded digitally and the analog domain where it is an electrical waveform.

    Problems with the digital circuitry

    Problems in the digital domain will usually be obvious to the point of being gross - extreme noise, noise correlated with the signal level, extreme distortion, tones or frequencies that with no stretch of the imagination were present in the original music, etc. Characteristics will be distinctly different than the kind of noise or audio distortion we are accustomed to in stereo equipment. Small errors in the digital reconstruction can result in totally gross changes in the audio output. For example, a single bit error if in the MSB can totally corrupt the resulting waveform. Simple errors can result in sound frequencies not present in the original. Fortunately, these sorts of errors are relatively rare as most of the circuitry is inside of very reliable LSI chipsets. However, if the CD is recognized and appears to behave normally except that there is absolutely no audio output, there can be problems in the audio decoding LSI chips. Other than hoping for an obvious bad connection, this is way beyond the scope of anything you can hope to repair without the service manual, test equipment, and a miracle.

    Problems with the analog circuitry

    Problems in the analog sections - D/A(s), sample-and-hold(s), post analog filters, and muting relays - produce effects that are more familiar: noise, decrease in signal strength, and distortion. Except for parts of the D/A which may be shared, there will be identical left and right channels to compare if an audio problem develops. If only one channel is affected, then the problem most likely has nothing to do with tracking, the laser, or the mechanism. Coming off of the disc, the left and right channels are interleaved on a sample (16 bit word) basis so any disc or pickup problem would equally impact both L and R. You are left with the D/A and sample-and-hold or D/As or the final analog filter and muting circuitry. Many CD players multiplex the D/A between L and R, so in these, even the D/A is ruled out since most of its circuitry is common. Swapping components one at a time between the identical left and right channels is also a valid diagnostic technique.
    • With a single D/A, there will be sample-and-hold circuits for each channel as well.
    • Players without digital filters (or oversampling) have fairly complex analog filters after the D/A. A bad or noisy component could conceivably be your problem. Even players with fancy oversampling have some kind of a final analog (antialiasing) filter. On an older player, there is probably a lot of discrete circuitry in the audio section.
    • If you can get to the components in the analog filter (some are potted), then with a test CD which has a 'silence track' and a scope or signal tracer, you should be able to find out where the noise is being introduced. If it has separate D/As, then one of these would also be suspect.
    • There may be separate power supply outputs for the audio section (this will be more likely with fancy expensive players). In this case, a failure of one of these may result in either distorted audio or no sound at all.
    The following will mostly result in static type noise, hum, or erratic audio (sound not coming on or partial or total dropout for one or both channels):
    • Don't overlook the simple problems of dirty contacts on the RCA jacks or bad connections where they are soldered to the main circuit board. Test by jiggling the cable connectors and/or prodding the circuit board near the RCA jacks. The cable may be bad (from flexing) as well - try another one. Check the connections and controls on your amplifier and other audio components as well! Any bad connection in the audio path can lead to these symptoms. Clean, repair, or replace as appropriate. Perhaps your poor, helpless CD player isn't even at fault!
    • Dirty muting relay contacts may result in intermittent or noisy output. If tapping the relay affects the symptoms, this is likely the problem. To test, remove the relay and bypass the suspect contacts with jumper wires. CAUTION: Turn your amplifier's volume control down when you start to play a disc - there may be unusual loud noises during startup that are now not blocked by the muting circuitry. If CDs now play without any audio problems, a bad relay is confirmed. It may be possible to snap off the cover(s) and renew them with contact cleaner and a burnishing tool or a strip of paper. Otherwise, replacement will be required.

    Problems playing/reading certain CDs

    While you may be tempted to blame *Big Brother* and some sort of diabolical copy protection scheme, I doubt that CD dependent behavior has anything to do with a lower intelligence at work. :) More likely, it is a bad quality control on the pressing. (This assumes your CD isn't one of those which has 85 minutes of music squeezed into a 74 minute space. See the section: Problems with extended length discs.) First, check for physical damage or imperfections on both sides of the CD. Even if you find nothing, trying a replacement disc would probably be a good idea before ripping apart your CD player. However, it may just be CD which produces an unusually low signal level. Depending on manufacturer, the signal level from CDs can vary by quite a large amount - maybe 30 percent (just guessing). Telarc discs were (maybe still are) particularly bad in this regard. CD-Rs are also quite variable and generally worse than normal CDs. (See the section: Problems reading CD-Rs). If the player is somewhat marginal to begin with (no way to really predict this), low signal level may mean either it won't recognize the disc at all or will be subject to skipping, audible noise, and other play problems. An internal adjustment might help but my advice would be that if it only occurs with a small percentage of CDs, better to leave well enough alone. However, a proper lens cleaning won't hurt! See the section: "General inspection, cleaning, and lubrication". If you really won't sleep knowing there might be something else you can do, see the "General servo adjustment procedure". I definitely don't recommend attempting to boost laser power - which would be considered a last resort. Note that newer CD players and CDROM drives may be more tolerant of damaged discs as well as CD-Rs (which became popular only relatively recently) - you may just be expecting too much from that 15 year old machine!

    Problems with extended length discs

    The specifications for the length of an audio CD is just over 74 minutes. I have seen them as long as 78 or 80 minutes which means that some of the basic CD specifications have been compromised - either the track pitch has been reduced or the track extends closer to the outside edge of the disc - or both. If the track pitch has been reduced, there could be tracking or audible noise problems throughout the disc. If the track extends closer to the outer edge, there could be problems near the end of the discs. The player may not these discs at all. Any of the following symptoms are possible:
    • No problems. Your player is one of those that is perfectly happy playing really long CDs. Most players will indeed be unaffected.
    • The disc may be rejected resulting in the display showing 'disc' or 'error' as though damaged, improperly inserted, or missing. In this case, the CD player's microbrain simply thinks anything with a total playing time exceeding 74 minutes and 15 seconds is invalid. Unless you want to redesign the player, there is nothing you can do to play these CDs. It might only require changing a single byte in the player's firmware :-).
    • There may be more of a tendency for skipping, sticking, or audible noise (probably near the end though it could happen anywhere if the track pitch has been reduced - including inability to read the disc's directory) since the servos are operating slightly outside their normal range. The actual likelihood of these types of problems are very slight, however. It may be possible to adjust the servos as described in the chapter: "Servo Systems and CD Player Adjustments". As with any adjustments, there is some risk of affecting performance for all discs - or totally messing things up. Or, if problems only occur near the end of these discs, just don't play them to the end!
    • The sled on which the pickup is mounted ventures into new territory where no sled has ventured before (at least on this player). Dirt, gummed up grease, hair, and other garbage may have collected there resulting in the sled drive mechanism getting stuck. You may hear whirring, buzzing, or clicking as the motor attempts to move the immovable - or nothing at all. Eventually, the player should probably shut down. In any case, kill power or remove the batteries to prevent damage to the gears. With luck, all you need to do is move the sled manually toward the spindle by turning the proper gear (freeing it up first, if necessary). Then clean and relube the track and gears. Hopefully, nothing is actually damaged since locating a replacement part may prove to be a challenge.
    • The sled simply overran the end of the rack and the drive gear no longer is capable of returning it to more familiar territory. You may hear some whirring, buzzing, or clicking as the gears attempt to mesh but do not quite succeed. Manually moving the sled so that the drive gear meshes with the rack - and then turning it a bit to be sure - should restore operation but, of course, you should not attempt to play these extended length discs to the very end in the future.

    Problems reading CD-Rs

    CD-Rs (recordable CDs, usually gold on the label side and greenish (or with newer ones like various PlayStation discs, some other strange color) on the readout side) can be quite variable in quality. They are often produced on a low cost writer of questionable design and calibration. It is quite common for a CD-R disc to play/read fine on one drive and not be recognized at all on another. There may not be any relation between cost of the CDROM drive and its reliability with CD-Rs. Note that newer CDROM drives (and probably CD players as well) may be more tolerant of CD-Rs (as well as of damaged normal CDs). 1X and even 4X CDROMs (as well as older CD players) predated the wide availability of CD-Rs so they weren't designed with them in mind. As a byproduct, newer technology may be more tolerant of bad normal CDs as well. So, there may in fact be an advantage to using high-X CDROM drives! So, it still has nothing to do with the high-X part, just that the low level circuits are smarter!

    Problems recording CD-Rs

    Consistently recording high quality CD-Rs is by no means as fool-proof as reading typical CDs. Any problems affect the recording quality permanently.
    • Media - there is significant variability in the quality and consistency of CD-R blanks from different manufacturers. You may have to experiment with multiple brands to determine those that work for you in your CD-R writer.
    • Recorder - there may be significant variability in the performance of various manufacturer's hardware. High price may not translate into high quality especially considering the rapid changes in the industry.
    • Writing speed - while it really should not matter whether you record at 1X or 4X (or whatever your machine supports), this may not actually be the case. If the servo systems are less stable at the higher rate, the quality of the recorded information may suffer. Thus, writing at a slower rate may be better - or may not matter. In any case, experimentation at different writing speeds should determine if this is an issue.
    • Media cleanliness - you only get one shot. A speck of dust or fingerprint - which might just decrease the signal to noise ratio when reading a CD - can degrade the writing laser beam resulting in malformed pits (oh no, not the dreaded malformed pit disease!). Inspect each CD-R blank before inserting it into the writer. Reject it if you see any visible surface damage or manufacturing defects. Use clean, dry compressed air if necessary to blow off any dust or fluff. Clean the surface as you would a CD to remove any fingerprints or smudges.
    • Equipment maintenance - keep the recorder clean - periodic inspection and cleaning similar to that used for CD players may be needed if it is used in a less than ideal environment - dust, smoke, and cooking vapors can quickly coat the lens leading to lower quality recordings. Inspect, clean, and replace (as necessary) the caddies (if used) as well since dirty or damaged caddies can cause problems as well.
    • Data under-runs - where the recorder does not have an internal buffer of sufficient size (yeh, like 650 MB!), it expects to be fed at a high enough rate to always have data available to send to the writing laser. Any failure will likely result in incorrect data being written - and probably a ruined disk. Some recorder software will simply abort. Even running another application like a screen saver can result in uncertainties with respect to data availability. When in doubt or where time is available, run the recorder at a slower speed to reduce the required datarate.
    • Mechanical shock - locate the recorder on a stable surface - not the top of a printer or other equipment that may be subject to movement during the duration of a recording session. Any vibration transmitted to the optical deck may cause a momentary shift in the position of the lens and laser beam reducing the recording quality. Bump it hard enough and the result will be mistracking and a ruined disk.
    There's an area of the CD-R disc used specifically to "calibrate" the laser. Since all disks have different needs (gold versus blue/green dye, for example) one-for-all power level won't do. If you laser has lost its power (they DO have a very finite life) which may be due to end-of-life OR dust on the lens (always consider a lens and any other accessible optics cleaning first!), it will FAIL this write-test and you will get what you are seeing. I would try a different color dye CD-R disc and see if there is one type it can still write to.
    From what I read, there is enough "write-space" in the laser-power-test area of the CDR for close to 1000 tests - which is why a new drive may work fine with your rejected discs. So, clean the lens, then try different types/colors of CD-R discs and then, if that still yields no results, write off the drive as "got my money's worth" and use it as a reader.

    Voice (almost) missing from CD playback

    My first thought would be to say "how can the electronics know about the voice separately?" Well, the answer is "it cannot". However, due to the way vocals are often recorded, this behavior is possible, if unlikely. What must happen is for the audio output to be the difference between the left and right channels mostly cancelling the centered vocal track but not having as much effect on the audibility of the instruments.
    It is possible for this to happen as a result of a bad ground connection or an electronic fault in the analog circuitry following the D/A stage but it is quite unlikely to be due to a problem in the optical pickup or digital decoding - though not out of the question. What is suggested below can happen by accident should the shield connection to the headphone or line out jack or cable become disconnected. (From: Frank Fendley (frank.fendley@datacom.iglou.com).) Actually, it is possible. Modify a headphone so that the two ground conductors are still connected together and to each earpiece, but no longer connected to the sleeve of the headphone jack. The two "hots" remain connected to tip and ring on the jack. Plug it in to a portable CD player and listen to a pop or country CD with (preferably) a solo vocalist. The vocals will almost disappear, while the instruments will still be quite audible (although now in mono). Normally, the lead vocals are 'centered' in the stereo imaging and are in phase on each channel. The instruments are panned more or less left or right. When you rewire the headphones, you effectively place the two transducers in series, and they are now wired out of phase with each other (the two "-" terminals are connected together on what used to be the ground lead, and the two "+" terminals are connected to their respective signal outputs from the channels - effectively since they are now in series, they are wired out of phase). Any signal which is "identical" and "in phase" on both left and right channels tends to cancel - the vocals. Signal which is not identical on each channel appears as the difference between the two sides - the instruments. Some recordings are not made this way and this will have little or no effect - you may have to try a few CD's to experience the 'phenomena'.

    Problems with anti-skip buffers

    Newer portable CD players often offer an extra cost option of an 'anti-skip' capability - usually about 10 seconds of buffer memory. While there is probably little you can do to repair an electronic or logical problem with this memory, there are a couple of points to keep in mind which may lead to the repair of problems like erratic anti-skip performance, noise, dropouts, skipping, and other symptoms dealt with elsewhere in this document.
    Anti-skip is actually implemented by reading ahead on the CD and storing up to 10 seconds of digital audio in dynamic random access memory (DRAM). This has a direct impact on optical deck performance and power requirements:
    • To read ahead, the player must actually operate at a higher than normal (1X) speed. Watching a player with this feature, it would appear to be close to 2X. This puts a greater strain on motors and servo systems so anything in the optics or servo alignment that is marginal - or even a dirty lens - may result in problems which do not show up with the anti-skip feature turned off. In addition, there are likely to be more problems reading marginal CDs or CD-Rs. See the section: CD player with skip buffer fails with some CD-Rs.
    • Power requirements are also greater with anti-skip on - the spindle motor and servos need to work harder and the buffer DRAM may require greater power when being accessed. Therefore, weak batteries or an inadequate wall adapter may result in erratic operation. If possible, try fresh batteries or a different adapter before warming up the oscilloscope.

    CD player with skip buffer fails with some CD-Rs

    This was an odd problem posted to the newsgroup sci.electronics.repair:
    "I am having an odd problem with my new portable cd player. It is a Panasonic with 10-second skip protection. I made an audio compilation CD with my CD-burner. This CD works fine with my CDROM drive and home CD player. In fact it works fine with the Panasonic UNTIL I turn on the skip protection. Then it plays for awhile, and for no apparent reason the seconds run out and it hangs up and displays the message 'Sorry'."
    (From: Mike Schuster (schuster@panix.com).) Your player is having trouble tracking the CD-R. Likely causes:
    1. The CD-R burner or software is producing discs whose layout is slightly off spec. A firmware or software upgrade may help if available.
    2. The CD-R burner works better with some types of blanks than others; and you've just discovered the ones it DOESN'T work well with. Try a different brand and color.
    3. You are using poor quality CD-R blanks which have an unacceptably high bit error rate, eccentricity of the spiral groove, or both.
    4. You are burning the disc as a speed which does not give the lowest error count with the media you are using - try faster or slower. Usually 2X write speed gives the best pit structure on the widest variety of media.
    5. Your CD-R burner is in need of calibration or laser replacement, resulting in poor pit shape. Have you tried an OPC test to see if it is delivering the right power?
    I have a Panasonic portable and have experienced the same thing with two Maxell CD-R's received in a trade. Of the dozens of CD-R's I own, these two, burned by the same person, are the only ones that cause trouble. For that reason I believe it is not the player but the discs that are "off".
     
    In skip protection mode the disc is played a double speed so it can keep the memory full. It must be having trouble tracking these discs at the higher speed, but is able to play them at normal speed. It's either a problem with the CD-Rs or just the way the player is.

    Problems with CDROM drives

    The newest CDROM drives operate at 12X speed or greater. Such performance puts significant strain on the motors and servo systems. Even 2X speed means substantially higher demands of the electronics and power systems. Thus, you may find that a drive will play audio CDs flawlessly but have trouble reading data files. While there is probably little you can do to repair an electronic or logical problem without schematics - which are almost certainly not going to be available, there are some things to keep in mind which may lead to the repair of problems like erratic or total failure of data readback.
    The first test for any CDROM problem is to force the drive to the 1X (or some slower speed than its maximum specifications) and see if that helps. Your drive may have come with instructions/software to operate at a selected speed. Data readout must be flawless. Uncorrectable errors which may not be noticed for audio playback would result in corrupted files. Thus, anything that is marginal may significantly impact performance. If it still has trouble with data even at the 1X speed, something may be marginal or there may be a true problem in the decoding logic or computer interface.
    • Multi-X performance puts a much greater strain on motors and servo systems so anything in the optics or servo alignment that is marginal - or even a dirty lens - may result in problems which do not show up with audio CDs played at the 1X speed. Thus, once a dirty lens is ruled out by cleaning it, some fine tuning of the servo systems may be needed.
    • At the high rotation rates used with the latest drives, even the slight imbalance caused by a label that is not uniform across the disc can result in enough vibration to affect the servo systems and result in an increase in data transfer error rate, mistracking, or even loss of focus and shutdown. There may be no problem with the drive itself - just the disc. It may be possible to add a small sticky label to the disc in a strategic location to improve balance. However, if the label is not very secure, it may fly off due to centrifugal force at high rpms and create yet another problem inside the drive. Some quick drying paint might be better. If only there were a tire balancing type machine for CDs!
    • Power requirements are substantially greater at the higher speeds - the spindle motor and servos need to work harder and even the electronics may require greater power. Therefore, weak batteries in laptop computers or CDROM drives operated off of laptop power or an inadequate wall adapter may result in erratic operation. If possible, try fresh batteries or a different adapter before warming up the oscilloscope.

    Portable CD player/CDROM drive power considerations - batteries

    As with all equipment operated from a batteries, there are specific requirements that must be met for reliable and safe operation.
    Batteries must be of the proper type. Some devices will work on either Alkaline or rechargeable NiCd types. However, since NiCds put out less voltage than fresh alkalines, there may be a selector switch or the instruction manual may state that NiCds should not be used. Batteries should be fresh - the motors, servo systems, and electronics in a CD player or CDROM drive can be a significant load when seeking or spinning up. A weak battery may cause it to shutdown erratically or never be able to find the selected track. Do not mix new and used cells. This can result in poor performance and may actually result in damage to the cells where rechargeable (NiCd) types are involved. Some CD players use a sealed lead-acid battery pack. For long life, these must be recharged immediately after use. Leaving a lead-acid battery pack in a discharged condition will significantly shorten its life. And these are not cheap! A pack for a typical Sony CD player may cost more than $20.

    Portable CD player/CDROM drive power considerations - AC adapters

    As with all equipment operated from a wall adapter, there are specific requirements that must be met for reliable and safe operation:
    1. Voltage. The CD player or other device will specify the nominal input voltage. This must be adhered to - you cannot connect a 3 V CD player to a 12 V adapter (or auto battery, for that matter). It will become toast. However, not all wall adapters are created equal. Some are very poorly regulated meaning that even though its label says something like '9V', the actual output may be as much as double this (or more) with no load. This may not be acceptable. The device may overheat or be damaged or destroyed nearly instantly. Internal protection devices may blow (if you are lucky!). It is safest to follow the manufacturer's recommendations (though, admittedly, they may be pushing their own brand of adapter). My rule of thumb is that if the unloaded output voltage is within about 25% of the specified requirements, it is probably safe to use. However, when connecting for the first time, be on the lookout for any strange behavior (or strange odors!).
    2. Current. The required current should be stated somewhere - either on the device itself or in the instruction manual. If only power is specified (i.e., 9 V, 4.5 W), then divide power in watts by voltage to get the current rating in A. (1 A = 1000 mA). The adapter must be capable of putting out at least this amount of current though a modestly higher current rating should be no problem. Using an adapter with an inadequate current rating may result in erratic behavior or overheating and failure of the adapter.
    3. Polarity. All the portable CD players and CDROM drives I know of operate on DC. Thus polarity is critical. Get it backwards and at best nothing will happen but nothing will work either. However, the equipment and/or adapter may be damaged - permanently. Internal protection devices may blow - if you are lucky.
    4. Regulation. It is often impossible to determine whether the device expects regulated power or whether a given AC adapter provides it without tests. There are both types. Higher voltage AC adapters (say, 6 V or above) often tend to be just rectifier/filter capacitor types. However, low voltage adapters (e.g., 3 V) may have an IC regulator built in.
    As noted in the section: CD player is totally dead, it is easy to destroy a portable device using an improper power adapter or a universal adapter that is configured incorrectly.

    Boomboxes and compact stereo systems

    These combine a stereo receiver and a single or dual cassette deck, and/or a CD player or changer, and a pair of detachable speakers, into a single unit. Most are fairly portable but larger boomboxes and compact stereos may require a forklift to move any great distance.
    While the individual subsystems - CD player for example - are usually relatively self contained electrically except for a common power supply, mechanically, everything tends to be jumbled together - even on units that have an outward appearance of separate components. Both cassette transports are usually driven from a single motor. Getting at the CD player may require removal of both cassette decks, audio amplifier, and power supply. Working on these is not fun. As usual, take careful notes as you disassemble the unit and expect it to require some time just to get to what you are after. Be especially careful when removing and replacing the individual modules if printed flex cables are used for interconnections. Refer to the relevant sections on cassette transports, loudspeakers, and power supplies for problems with these units. Since these do get abused - bumped, dropped, dunked, etc., bad connections, and other damage is very common. See the sections: "Intermittent or erratic operation" as well as "Audio muting, noise, or distortion".

    CD player was dropped or got wet

    I have never heard of a component CD player being dropped or rained on. However, this does happen to portables. While a service shop may not even want to tackle such a unit, it is quite possible that damage is minimal - even for a CD player.
    With a CD player that has been dropped, unplug it from the AC line or remove the batteries immediately. This will prevent further damage should anything be shorting internally. For one that has gotten wet, dry it immediately (you knew that!). See the document: Audio Equipment and Other Miscellaneous Stuff for more info on restoration of abused audio equipment.

    Repairing flexible printed cables

    It seems that more and more consumer devices from pocket cameras to laptop computers are being built with miniature multiconductor flexible printed cables. Very often one or more traces to develop hairline cracks due to repeated flexing. In addition, damage from moving circuit boards and modules during servicing is all to common.
    Needless to say, repairing any kind of flex cable is a real pain. I have succeeded by carefully scraping the plastic off with an Xacto knife and then soldering fine wire (#30 gauge wire wrap for example) to the traces. This presumes that the conductors on your cable will even take solder. I then cover up the joints with a flexible sealer for electrical and mechanical protection. However, you need to make sure that the wire you use can be flexed or that the joint is set up in such a way that the wire does not flex much - else you will just end up with broken wires pretty quickly. Here is another alternative if the flexing of the cable prevents the use of ordinary wire for jumpers: Find a piece of somewhat similar flex cable cable from a dead piece of equipment. Use it to jumper across the high stress area and then solder it to the other cable with short wires if necessary. Then coat the connections as above. Soldering from end point to end point if possible may be preferable. Even going to only one endpoint would reduce the risk of immediate damage and reliability problems in the future. With multiple traces broken or damaged, you are probably better off replacing the cable entirely. With the typical flex cables found in CD players, there is often no way to repair a large number of broken traces and retain your sanity.

    CD player whine

    CD players are generally nearly silent during play (though they may make a variety of whirring and clicking noises when loading discs, initializing, or seeking). The only sound normally eminating from inside the machine during play might be a very faint gritty noise from the focus and tracking actuators.
    Thus, a sustained whine would generally be considered abnormal. (Portions from: Larry Sirignano (sirig@esslink.com).) There are two likely causes:
    1. Worn spindle motor bearings can result in a high pitched whine. In this case, adding a drop of oil may quiet it down temporarily but replacement will eventually be needed.
    2. The whining noise may be the laser/chassis assembly resonating with the CD as it spins. Depending on the model, there is a cure - adding a weight or damping material to the pickup or the chassis to change the resonant frequency. To confirm that this is your problem, gently rest your finger on the rotating clamper disk and/or other parts of the optical deck while it is whining - the whine should change or disappear. If you can locate a particularly sensitive spot, try gluing a piece of heavy rubber to this location (even if it is the clamper disk) with rubber cement. If this solves the whine problem, confirm that discs seek and play correctly for all tracks before buttoning it up. 
    I would try lubricating the shaft of the spindle motor, and check to see if the motor brushes might be partially shorted. (not to worry you at this early stage, but sometimes Sony pickups, especially the KSS240 and KSS212 and 213, have resonance problems, often just as the disc is coming to speed.) This is the subject of at least a couple service bulletins. Can often be heard as a whistling tone coming from the mechanism usually intermittent, and can be observed in the focus error and tracking error lines as a sine wave overriding what should be essentially a random noise signal. Occasionally the resonance gets so pronounced the disc won't even spin up.
    It happens with some Pioneers as well. It's not a common symptom, but it is the pickup at fault. Look at the focus error line and you'll see a sine wave riding on it. There is essentially a feedback loop existing between the spindle motor/subchassis and the pickup. I've seen various attempts to damp it out but replacing the pickup fixes it every time in my experience. 

    It's possible that a loose lens can result in a resonant condition so check that the lens is secure. If it falls out in your hand, gluing it back in place should solve the whining and prevent a future problem.

    Noisy CD player

    CD players are not silent despite all the hype to the contrary. The focus and tracking actuators act like voice coils in loudspeakers produce various chirps and hisses while playing a CD. When seeking, the sled motor adds its own additional instrumental accompanyment. :)
    As they say, "If it ain't broke, don't fix it." Assuming it plays CDs fine and has always been this way (or you don't recall how it was when you first got it), leave well enough alone. If you do decide to twiddle pots, mark their original position carefully before doing anything! The ones most likely to have any effect are the gain controls for focus and tracking. Lowering the gain slightly (perhaps 1/8th of a turn counterclockwise) will reduce the noise level - but may also result in more susceptibility to skipping from vibration. Turn them too far and the disc will no longer even be recognized. These adjustments don't generally change on their own so think several times before possibly making matters worse. Perhaps, putting the CD player in a box padded with sound deadening insulation would be a simpler solution if the noise bothers you! Also see the section: CD player whine.

    Objective lens popped out

    Don't expect to see this one too often. However, on some Pioneer changers where the pickup is mounted upside-down, tired pickup suspension grommets, excessive heat, age, long use with warped discs, or just bad luck, has apparently resulted in the adhesive holding the objective lens in place to come unglued, as they say. :-) In some cases, it is still attached but loose, which will also prevent the player from working but may be easier to fix than one that is rolling around at the bottom of the cabinet.
    The best solution is to replace the entire pickup. However, you have nothing to lose by attempting to reattach the lens IF you can locate it AND its optical surfaces are undamaged from the ordeal. If either of these is not the case, you will probably have to install an entire new pickup. Swapping of a lens from another player is even less likely to work unless it uses a similar pickup from the same manufacturer and then only with great pain. But in many instances, Murphy has taken the day off because (1) the optical surfaces are recessed and relatively well protected from bumping into stuff and (2) there are no holes in the cases of these players for the lens to sneak through and get lost (that is, until you remove the cover not realizing the lens is trying to escape!). It may be essential to line up the lens in EXACTLY the same position as it was originally in terms of centering as well as the same orientation to have any chance of success. (However, I've never actually seen this):
    • The lens must be centered for the return beam to be properly aligned with the photodetector array.
    • It is possible that some lenses are astigmatic (not circularly symmetric) to implement the focus servo (rather than using a separate cylindrical lens or thick beam splitter mirror for this purpose). For these, the orientation is also critical. When this is the case, there will be a reference on the lens for this purpose. On Sony pickups, for example, there is a flat filed on one edge of the lens. (You always wondered why the lenses in all your Sony CD players appeared to be 'damaged', didn't you?) However, I do not know of any Sony or other models that actually use an astigmatic objective lens. (Sonys usually have a thick beam splitter mirror for this purpose. Pioneer players for which the dropped lens syndrome is quite common don't have an astigmatic lens because people have reported replacing the lens in any position without problems.) However, matching up the lens position with the old glue line will likely result in it being better aligned with the internal optics so it's still worth doing if possible.
    Alignment isn't so bad if you can see the failure line in the old glue or if the lens isn't completely detached. Otherwise, you will need to compare the orientation with an intact sample of a pickup from the same manufacturer that uses a similar optical configuration. Just guessing may not work! Carefully position the lens and put the tiniest drop of adhesive such as 5 minute Epoxy at three points roughly equally spaced around the edge of the lens. DO NOT use anything with a volatile solvent like windshield sealer, Duco Cement, or especially instant glues like (Gasp!) Krazy Glue (cyanacrylic, even if you have mastered that disaster!) The vapors may condense on the lens or other (more inaccessible optical surfaces). Take care to prevent any glue runing down into the suspension or elsewhere. Once the glue has set, reinstall the pickup and try it. If behavior seems reasonably normal, put a tiny bead of adhesive all around the lens to anchor it securely. Some servo adjustments and/or optical alignment may still be needed to correct for the slight shift in lens position that is unavoidable from this surgery. I experienced the problems of instant glue when a colleague brought in a Pioneer changer in which he had attempted to reattach the lens. Looking into the lens, it appeared as though there was an aperture behind it. After prying the lens back off, it became apparent that the effect was caused by a haze which had formed a sort of ring around the underside of the lens. Fortunately, multiple cleanings with isopropyl alcohol removed most of it and allowed the player to recognize and play discs, though I don't think it will ever have quite the same performance. Before powering up, check the pickup suspension grommets for wear or deterioration, your discs for serious warp, and any other mechanical problems that could cause the same thing to happen again. Don't use seriously warped discs. Replace bad grommets or at least raise the pickup by installing washers under it for testing. For the most common Pioneer pickups, the highly curved surface of the lens goes into a recess and is a snug fit so all the glue needs to do is hold it there. There is a flat molded on one side of the lens and this is positioned on the right side with the pickup held so the motor is at the bottom (though it may not matter at all). Place 3 tiny dabs of 5 minute Epoxy just inside the lip of the recess 120 degrees apart. After cleaning the curved underside of the lens with a couple drops of pure isopropyl alcohol on a cotton swab and allowing it to dry, place it in position with a pair of plastic tweezers. Then, gently press it down to seat it. Carefully rotate the lens to align the flat if necessary. Once the Epoxy cures (give it 10 minutes to be sure!), clean the outer surface of the lens and reinstall the pickup. (From: Dave (albrecht@se-iowa.net).) A local radio station uses about 20 Pioneer PD-M510s. I've been replacing a lot of lenses that are starting to fall out. I usually do a "shake" test, recover the lens and glue it back in place. Not bad considering most haven't been shut off and have played for 4 years now.  

    The lens falls out because of 2 factors: (1) The laser is mounted upside down or (2) the rubber grommets that support the pickup wear out after time as does the spring in the optical pickup allowing the lens to be hit by the disc slide tray in the changer as the player loads each disc. (In marginal cases, the lens may actually scrape and scratch the disc during loading or play but will still be attached.)
    Sometimes regluing the lens is enough to allow the unit to play, but not a good repair unless the rubber grommets are replaced and the sagging height of the lens measured to ensure enough clearance. Then the laser output and RF level must be checked. I have only found one laser that had the lens fall out that was not way below specification and needed replacement to make for a reliably playing unit. That being said, most people are happy to pay just the minimum to have the lens glued on and the 3 ring paper hole reinforcement pads put in as spacers to allow the unit to play as the cost of the optics and rubber grommets alone are close to replacement cost of the unit.

    Testing the optical pickup

    See the special section "Testing of Optical Pickup Assemblies" for detailed procedures for determining basic functionality of most of the optical, electronic, and mechanical components in the pickup assembly. These techniques do not require sophisticated test equipment and will identify most common failures. However, you should not consider such involved tests until you have eliminated other possibilities for your particular problems.

    Replacing the optical pickup

    If after these tests (or for other reasons) you are fairly confident that the optical pickup is defective and not salvageable, replacements are usually available from both the original manufacturer and service parts suppliers like MCM Electronics and others.
    Costs range from less than $40 to well over the price of several new CD players so you need to decide (1) how confident you are in your diagnosis (pickups are probably not returnable) and (2) how much you are willing to invest in a repair. The actual replacement procedure is usually straightforward but care must be taken to avoid damage to the usually fragile flex cables. Also, take ESD precautions since the laser diode, in particular, is quite sensitive to static. There will usually be a solder jumper between a pair of traces shorting across the laser diode to prevent such damage - remove this only after the pickup is fully installed and its connectors are plugged in. (However, if you don't recall such a jumper and you are experiencing a 'dead laser' symptom, check for it! Note: Some pickups like those from Pioneer apparently come from the factory unaligned. I have no idea how the test them! :) In any case, this means that substantial work is needed to get them to work, probably requiring a service manual, oscilloscope, and a test disc (though I don't believe the latter is absolutely necessary).
     

    Servo Systems and CD Player Adjustments

    Servo systems

    There are several servo systems in a CD player:
    1. Focus - maintains a constant distance to within 1 um (1/25,000th of an inch!) or so between the objective lens and the disc. This must be maintained even with a slightly warped or uneven disc and in a portable player, with a certain amount of movement as well. Focus is accomplished with a voice coil type of positioner (similar to operation of a loudspeaker) using optical feedback from the disc surface. See the chapter: "Startup Problems" for a description of how this and fine tracking (below) operate.
    2. Fine tracking - centers the laser beam on the disc track (to within a fraction of a um) and compensates for side-to-side runout of the disc and player movement. This also uses a voice coil positioner and optical feedback from the disc surface. (Note: on rotary type pickups, there may be no separate tracking coil as its function is combined with the rotary positioner.)
    3. Coarse tracking - moves the entire pickup assembly as a function of fine tracking error exceeding a threshold or based on user or microcontroller requests (like search or skip). Coarse tracking uses several types of positioners depending on performance requirements. It may either be a worm drive, a gear drive, a linear motor, or rotary positioner - in order of increasing access speed. The linear motor and rotary positioner have no gears and simply use a coil and permanent magnet to move the entire pickup very quickly - similar to a voice coil but on a larger scale. CDROMs, especially the high performance models, usually use this type of actuator to achieve their relatively fast access. These may have some type of lock to prevent the pickup from banging around when the unit is moved with power off. Note: for a CDROM drive that uses a caddy - always remove the caddy before transporting the drive or the equipment that it is in. The loading of the caddy often unlocks the pickup permitting it to flop around during movement and possibly being damaged. A linear motor or rotary positioner driven pickup should move very smoothly and easily by hand when unpowered and unlocked. Note that the use of a rotary positioner is no guarantee of fast response. One of the earliest CD players - a Magnavox unit apparently manufactured by Philips - has about the slowest track seek time I have ever seen and uses a rotary positioner. Watching it go from one track to another is like watching an inch worm crawl along - ssst, ssst, ssst (the sound made as the focus actuator vibrates while crossing tracks), ssst, ssst.
    4. Spindle speed - maintains constant linear velocity (CLV) of disc rotation based on a PLL locking to the clock signal recovered from the disc. Spindle drive is most often done with a permanent magnet DC motor connected to the disc platform. It may be similar to the other motors in CD players and VCRs, (as well as toys for that matter), or a higher quality brushless DC motor.

    Play adjustments

    You will see a circuit board, hopefully in your unit it is readily accessible with component markings. For each servo, there will be 1 or 2 pots to adjust. Unfortunately for our purposes, some CD players have no adjustments! In this case about all you can do is confirm that the lens is clean and clean and lubricate the mechanism.
    The adjustments will be labeled something like:
    1. Focus - F.G. (focus gain), F.O. (focus offset)
    2. Tracking - T.G. (tracking gain), T.O. (tracking offset), maybe others.
    3. Spindle PLL, PLL adj., Speed, or something like that.
    DO NOT TOUCH THE LASER POWER ADJUSTMENT - you can possibly ruin the laser if you turn it up too high. Sometimes, just turning it with power applied can destroy the laser diode due to a noisy potentiometer. This adjustment can only be made properly with the service manual. It may require an optical power meter to set laser output. Very often the adjustment is on the optical pickup itself so it should be easy to avoid. Sometimes it is on the main PCB. The laser optical power output is feedback controlled and unlikely to change unless the laser is defective - in which case adjustments will have little effect anyway. If you run out of options, see the section: Laser power adjustment - last. DO NOT JUST GO AND TWEAK WILDLY. You will never be able to get back to a point where the disc will even be recognized (without test equipment and probably a service manual). First, somehow mark the EXACT positions of each control. Some of these may require quite precise setting - a 1/16 of a turn could be critical, especially for the offset adjustments. Sometimes, there will be marked test points, but even then the exact procedure is probably model dependent.

    Adjustment procedure for noise or skipping

    The assumption here is that you can get the disc to play but there is audio noise skipping, or other similar problem.
    Play a disc at the track that sounds the worst - put it into repeat mode so it will continue for awhile. Get it to play by whatever means works.

    Repetitive noise at disc rotation frequency

    Try to locate the adjustments for focus. Try the focus offset first, just a hair in each direction. If you go too far, you will loose focus lock totally, the servo will go into focus search mode and/or the unit will shut down. Return the control to the exact original position if there is no improvement. You can also try gain, but in my experience, the gain controls are not critical to normal play but determine how the unit will handle dirty and/or defective discs. However, if they are way off, there could be general problems. Too low a gain setting (this applies to focus as well as tracking) will make the unit very prone to skipping as a result of minor bumps. Too high a setting will make the unit skip as a result of minor disc defects.

    Short distance skipping or sticking

    Try to locate the adjustments for tracking. Try the fine tracking offset first, just a hair in each direction. If you go too far, you will loose servo lock totally, the pickup will slew to one end of the disc, and/or the unit will shut down. Return the control to the exact original position if there is no improvement. Then try the other tracking offset if there is one and also the gain (though this is probably not the problem).
    Always return each control to its original position after the test so you don't confuse things more.

    General servo adjustment procedure

    If you have a service manual for your player, by all means follow its recommendations or at least read through its adjustment procedures before attempting the one given below. If you have an oscilloscope of at least 5 MHz bandwidth, using it to monitor the RF testpoint during these adjustments will be of great value. However, a scope is not essential.
    • Once focus lock is established, there should be a strong signal at the RF testpoint - typically around a volt or so. It may initially appear somewhat random, however.
    • Once tracking lock is established, this signal should appear similar to the 'eye' pattern (see section: The CD player 'eye' pattern for details. However, while seeking, this may be jumping around somewhat as it attempts to home in on the correct track location.
    If your CD player has a TEST MODE, see the section: Pioneer PD/M series servo adjustment procedure and modify it accordingly. The following procedure is for a typical unit without such a test feature. It assumes that the unit is functional but internal controls are not in their correct position. This might be the case if you violated rule #1 - never wildly tweak any internal adjustments! Or, if a major subassembly like the optical pickup or mainboard has been replaced. If you have not touched the internal controls and no major parts have been replaced, there is no need to perform this procedure. Use techniques and observations discussed elsewhere in this document. The following are assumed:
    • Controls on the main board are in an unknown state but not any laser power adjustments (hopefully, these were on the optical pickup itself or its flex cable and were not touched.
    • The player is otherwise functional - there is no physical damage.
    You may need to modify this procedure based on your particular model. Some of the adjustments may go by different names or be non-existent. Use your judgement. Except for the laser power adjustment, which should be avoided, it is unlikely that any settings of these controls will result in permanent damage. Some of these adjustment will need to be performed while the unit is in the startup sequence attempting to read the disc directory. Until focus and possibly tracking and CLV lock are established, it may give up fairly quickly. You will just need to keep cycling power or opening and closing the drawer to get it to repeat the attempt. Once some subset of the servo adjustments are set within reasonable limits, the player may continue to spin the disc ad-infinitum. Hopefully, the adjustments on your player's mainboard are clearly marked. This is not always the case. I have restored a totally messed up portable with totally unmarked controls to a marginal state of happiness using an incremental procedure while observing changes in behavior and the signal at the RF testpoint with an oscilloscope. It was not fun and I never was able to really make it fully functional - seeks still have a problem though it will start track 1 most of the time and once started, play is flawless. (I suspect that there may be actual electronic/optical problems with this player in addition to the randomly tweaked controls). I even had to poke at random (testpoints were marked only with TP numbers) to locate the RF testpoint! Use both your eyes and ears. The following may not apply but are probably worth considering:
    • If the sled slews to one end of the track immediately upon power-on or loading of the disc, there may be a coarse tracking balance control that is set incorrectly.
    • If the disc does not start spinning at all, focus lock is probably not being achieved. Concentrate on the RF and focus adjustments.
    • If the disc spins hessitently or in the wrong direction or the sled slews to one end of the track after the disc starts spinning, there is a good chance that the tracking adjustments need attention.
    • If the disc goes into overdrive, check the PLL/VCO/CLV adjustment (whatever it is called on your model).
    • If the disc starts spinning and continues to spin at the correct speed (500 to 200 rpm depending on track position) without the player shutting down, a valid data-stream is probably being read. This indicates at least marginal RF, focus, tracking, and PLL/VCO/CLV settings. This doesn't mean you can ignore these adjustments but at least it is progress!
    • If the disc directory (TOC) is read successfully but the player has trouble locating a track to begin play (even track 1), concentrate on the tracking adjustments - focus and PLL/VCO/CLV are probably fine.
    If the player works but there are noise or tracking problems and you have an oscilloscope, see the section: Diagnosis of erratic play first as the simplified procedure described there may be more appropriate.
    1. Precisely mark the current positions of all internal adjustments - just in case they were already set correctly!
    2. Set all main board controls to their midpoint.
    3. Adjust TR BAL (Tracking Balance) to the center of the range over which the sled remains stationary. Outside this range, the pickup will slew to one end or the other. Not all CD players have this control. A CD may need to be in place for this adjustment to have any effect. If you are unable to get the pickup to remain stationary, try fine tracking offset (TR.OFF) as well.
    The following two items should be done with no disc in place. If your player does not have suitable test points or if these controls have no effect without a disc in place, skip them.
    1. While monitoring the testpoint for focus error (e.g., TP.FE), adjust focus offset (FO.OFF) for 0 volts (+/- 10 mV or so). This may not be the optimal setting but will get you in the ballpark.
    2. While monitoring the testpoint for tracking error (e.g., TP.TE), adjust fine tracking offset (TR.OFF) for 0 volts (+/- 10 mV or so). This may not be the optimal setting but will get you in the ballpark.
    3. If you have a DMM, VOM, or scope, put it on the Focus OK testpoint if there is one.
    4. Load a disc and press PLAY if necessary to initiate the startup sequence.
    5. Confirm that focus is established. There is an adjustment range for Focus Offset over which focus will be reliably achieved. Outside this range:
      • he lens will hunt up and down - possibly with clicking sounds as it bumps into the end stops.
      • The Focus OK testpoint will not be asserted or will be jumping around as well.
      • The disc may never start spinning or spin erratically (model dependent).
      • Single play units will give up and enter stop more with display of 'disc', 'no disc', 'error', etc. Changers will come up with similar display and then move on to the next position of the carousel or magazine.
      Center the focus offset within the range for which focus is stable if it was not already there.
    At this point there is a fair chance that the disc has started to spin and even that the disc directory has been displayed. If not, there are still two sets of adjustments remaining.
    1. With focus stable, the disc should spin up. It needs to reach and lock at about 500 rpm - roughly 8 revolutions per second. If it does not move or overspeeds, try adjusting the PLL/CLV control (may be called PLL.ADJ, VCO.FR, CLV.ADJ, etc.). Note: this assumes that the spindle motor and driver are in good condition. If there is any doubt, see the section: Testing of motors.) WARNING: if the disc spindle speed runs away, turn power off and wait for spindle to stop completely. PLL/CLV control may be set to high; turn it counterclockwise 1/4 turn and start try again. There will be some range of this control where the speed will not run away but will be within the required limits.
    Now, there is an even better chance that the disc has started to spin and that the disc directory has been displayed. If not, there is still one set of adjustments remaining.
    1. Fine tracking offset may still not be quite right. Try some slight adjustments on either side of the current position. You may have to cycle power or open and close the drawer if you go too far. Some adjustments of alternately fine tracking offset and PLL/CLV may be needed.
    Hopefully, you now have a disc directory and play may be operations though perhaps with audio noise and/or skipping or sticking. The following are best done with a scope monitoring the 'Eye' pattern or other testpoints but if you do not have one, use your ears.
    1. Adjust PLL/CLV control to midpoint of range in which disc plays correctly. Test this at both the start and the end of a full length (74 minute) disc. The optimal setting will result in the control being centered within the range over which the player works reliably at both ends of the disc.
    2. Adjust any RF Offset (RF.OFS) control to the midpoint of the range over which play continues normally with no audio noise.
    3. Set Focus Gain (FO.GAIN or FO.G) to the midpoint of the range over which it locks. CAUTION: the disc may enter a runaway state if you go to far. Check at both the beginning and end of the disc. Focus gain may need to be increased if the player is overly sensitive to bumps or disc wobble It may need to be decreased if sensitivity to disc defects is too high.
    4. Set Tracking Gain (TR.GAIN or TR.G) to the midpoint of range over which it locks. CAUTION: the disc may enter a runaway state if you go to far. Check at both the beginning and end of disc. Tracking gain may need to be increased if the player is overly sensitive to bumps or disc wobble. It may need to be decreased if sensitivity to disc defects is too high.
    5. Press STOP and then PLAY again to confirm that the disc loads properly and the directory comes up quickly and the music starts without excessive delay, hunting, or hesitation.
    6. Test forward and reverse search and seek functions for proper behavior. Some slight adjustments to tracking balance or fine tracking offset may be needed to equalize the forward and reverse search or seek speed.
    7. Player should now operate normally. However some tweaking of the gain controls may be necessary (as described above) for optimum defective disc and track seek performance over entire disc.
    If you have an oscilloscope capable of at least 5 MHz bandwidth, you can now optimize the amplitude and stability of the 'eye' pattern at the RF testpoint by going back and touching up the various offset (RF, focus, fine tracking) adjustments. Unless otherwise instructed by the service manual, it is probably safe to assume that the RF signal should be maximum when everything is properly adjusted. For example, if the tracking offset and/or E-F balance is not set properly, you may find that the RF signal amplitude *decreases* when the tracking servo is closed since the laser beam is consistently off-center with respect to the row of pits and lands. (With the servo loop open, the beam was crossing tracks more or less at random so it was sometimes centered!)

    Rule of thumb for setting focus and tracking

    If you want a quick easy way to set the focus bias, when you've replaced the laser, or done whatever you need to get the player going ( and yes, I agree that laser failure in Aiwas is VERY common ), just set the focus gain up higher than normal, and play a less than perfect disc. Stick your ear down close to the laser, and you will hear the tracking noise from the surface scratches. Now carefully swing the focus bias pot either side of centre, and listen for the null in the tracking noise. Set the pot to this point, and leave it. The tracking balance pot can be set in the same way, but you have to listen a little more carefully. Set the tracking gain and focus gain pots just on the high side of centre.
    In the absence of the proper instructions, this rule of thumb setting procedure, will work for any four-pot player, and give reliable results.

    Tips for adjusting CDROM drives

    The following assumes that your CDROM driver and MSCDEX (if required) load without errors and that your IRQ, DMA, and any other software settings are correct but that seeks take a long time to complete or fail and/or data reads are unreliable.
    If you can get the CDROM drive to play an audio CD, that can be used to do an initial alignment. The procedure below provides a way of monitoring data read performance while performing final servo adjustments since this is more critical than audio. Assuming, of course, that (1) there are any controls to adjust and (2) that you can get to them with a disc in place! If after using the procedures described in the section: General inspection, cleaning, and lubrication, and possibly even servo alignment using an audio CD, the drive still produces data errors or cannot be read at all, it is time for more serious testing: 

    I'm pretty sure that Disk Detective (the limited version rather than professional version) can be downloaded over the internet from filelibrary.com (click on DOS collection, followed by Utilities-Disk then files beginning with C). I use the limited version that ships with a new Mitsumi IDE drive. It works perfectly on IDE, Mitsumi, SCSI, and likely any other interface drives, and it does not require the presence of any Mitsumi drive or controller. If you can't find Disk Detective, then search for CD-ROM, CDROM, or CD ROM at: http://www.shareware.com/, and you'll find CD-ROM diagnostic programs.
    In Disk Detective, there is a Test Disk menu option that scans the entire disk, and gives a continuous output to the screen of read errors it encounters, giving the type of error and the average data throughput. Now using Disk Detective (or a comparable program), load a disk into the drive and select the test disk option, and tell it to scan the disk from beginning to end, and tell it not to stop when it encounters an error. Disk Detective should start trying to read the disk at sector zero, and will display read errors as it encounters them. You might have to load an audio disk rather than a data disk in order to be able to get to the Test Disk screen. With the Test Disk screen displaying the errors as it attempts to read the drive, it will be possible to carefully tweak each of the servo adjustments (as described elsewhere in this document) to minimize errors and maximize throughput.

    Low laser power

    Indications of reduced laser power include erratic startup, noisy playback. excessive variation of playback quality depending on the particular disc, or total lack of startup.
    WARNING: improper adjustment of the laser power may result in the absolutely instant destruction of the laser diode - the heart of your CD player. There will be no warning. One moment you have a working laser diode, the next you have a DELD - Dark Emitting Laser Diode. Read the relevant sections fully before attempting any adjustments. Nothing will help a dead laser diode - whether as a result of your efforts or natural causes - short of replacing the optical pickup. Very likely, low laser power indicates a sick laser as well and adjustments will have limited if any effect since optical feedback normally maintains laser diode output at the proper level and it may be doing all that is possible. However, sometimes due to component drift (this one way of saying: I haven't got a clue), the power will drop slightly or the sensitivity of the photodiode array will decrease resulting in a marginal signal. If you have the service manual and it provides a procedure not requiring a laser power meter (which you probably do not have), then by all means follow that procedure. Otherwise, see the section: Laser power adjustment for procedures that may be used as a last resort.

    Optical alignment

    Unless the unit was dropped, optical realignment of the laser assembly is not likely to be needed. All critical components are screwed, sealed with loctite, or glued, and should not change alignment under normal use. Don't fall for the line 'CD players are very delicate and will need frequent alignment - buy our extended service plan'. CD players are remarkably robust. Portables, even when nibbled on by large dogs, often survive unscathed. I even carried a component type CD player home from a garage sale 5 miles on the back of a 10 speed road bike over city streets complete with potholes! No problems. In fact, it improved. The seller claimed that it was broken but I could find nothing wrong! One possible exception is for automotive units which are subjected constantly to bumps and vibration which eventually take their toll.
    If you really believe that optical alignment is needed, I strongly recommend that you obtain the service manual. Special test discs or jigs may be required and some test equipment will be required. As with other adjustments, make sure you can get back to your starting point should the need arise. Again. eliminate other possibilities first if possible.

    Motors and Spindles

    Small motors in CD players

    Conventional miniature Permanent Magnet (PM) motors are usually used for:
    • Drawer/tray opening/closing.
    • Spindle rotation.
    • Pickup position (coarse tracking) unless the unit uses a linear motor or rotary positioner drive.
    • Disc changing (changers and jukeboxes only).
    • Optical pickup tilt (laserdisc players only).
    These are DC motors with commutators and metal brushes and are very similar in construction and quality to typical motors found in cameras, toys, portable tools, and other electronic equipment like VCRs and audio cassette decks. They usually run on anywhere from a fraction of a volt up to 10 or 12 volts DC on-off (e.g., drawer) or from a servo controller (spindle). Some CD players and CDROM drives use brushless DC motors for spindle driver rather than the cheap PM brushed variety. The commutation circuitry for these may be external to the motor itself. Troubleshooting beyond searching for bad connections will probably require a schematic. Sled movement in high performance CD players and CDROM drives often uses either a linear or rotary direct drive (voice coil) mechanism. Since these are integral parts of the coarse tracking servo system, the only thing that can be tested without a schematic is for coil continuity.

    Problems with small PM motors

    These motors can fail in a number of ways:
    • Open or shorted windings - this may result in a bad spot, excess load on the driver, or a totally dead motor.
    • partial short caused by dirt/muck, metal particle, or carbon buildup on commutator - this is a common problem with spindle motors which fail to reach proper startup speed.
    • dry/worn bearings - this may result in a tight or frozen motor or a spindle with excessive runout.

    Testing of motors

    If your player uses a brushless DC motor for the spindle then you may not be able to perform any electrical tests as the commutation control may be external on the circuit board somewhere. These do not fail very often, either.
    An open or shorted winding may result in a 'bad spot' - a position at which the motor may get stuck. Rotate the motor by hand a quarter turn and try it again. If it runs now either for a fraction of a turn or behaves normally, then replacement will probably be needed since it will get stuck at the same point at some point in the future. Check it with an ohmmeter. Also check between each terminal and the case - the reading should be high, greater than 1M ohm. A low reading indicates a short. The motor may still work when removed from the equipment but depending on what the case is connected to, may result in overheating, loss of power, or damage to the driving circuits when mounted (and connected) to the chassis. Clip the ohmmeter leads to the motor terminals and rotate the shaft extremely slowly. The motor will act as a generator as your spin it resulting in the resistance readings increasing or decreasing depending on direction. However, the readings should stabilize once you stop. The resistance should be fairly constant as the shaft is rotated with periodic dips where pairs of commutator segments are shorted by the brushes. The number of cycles per revolution is determined by the number of commutator segments used (most use only 3). Any extremely low reading may indicate a shorted winding. An unusually high reading may indicate an open winding or dirty commutator. Cleaning may help a motor with an open or short or dead spot as noted below. Typical resistance of these motors will be 10 to 25 ohms (though I have seen some apparently good motors reading as low as 5 ohms), fairly constant as one rotates the shaft except for dips at 3 points where the brushes short out each pair of commutator segments (there are generally 3 segments on these motors). A motor can be tested for basic functionality by disconnecting it from the circuit board and powering it from a couple of 1.5 volt alkaline cells in series (3 V) or other power supply up to 9 V or so. WARNING: Never attempt to power a motor with an external battery or power supply when the motor is attached to the circuit board - you may blow electronic components on the circuit board and complicate your problems. Disconnect *both* terminals and label the wires or motor orientation so you can reconnect it with the proper polarity. If you use a variable power supply, the motor will start spinning slowing at less than a volt and continue without tending to stop at some point in its rotation. Using your fingers to monitor the torque produced as it rotates can also provide an indication of its health. It should be fairly uniform with slight periodic dips due to the commutator construction and number of segments. Another approach is to power the motor from the low voltage source through a low value series resistor and monitor the voltage on the motor with an oscilloscope. It should have a periodic ripple at the rotation times the commutator (probably 3) rate. If there are sharp dips at the based rotation rate, there is a short either due to conductive gunk or actual shorted turns in the windings. If there is excessive noise in the waveform, the brushes and/or commutator may be dirty or worn. It is also possible to confirm that the electronics are attempting to drive the motor by substituting a 15 or 20 ohm 1 W resistor for the motor. The driver circuit should develop a few volts across this load when it is supposed to be active. If there is no voltage at any time, then the driver may be blown or not have power, or the logic is not instructing the motor to spin!

    Reviving a partially shorted or erratic PM motor

    Conductive material bridging the gaps on the commutator of these small permanent magnet DC motors can result in intermittent contact and erratic operation. One theory baseed on an analysis done for a major manufacturer was that the origin of the contamination is the original lubricants used in the motor. Carbon or metal particle buildup can partially short the motor making it impossible for the controller to provide enough voltage to maintain desired speed. Sometimes, a quick squirt of degreaser through the ventilation holes at the connection end will blow out the shorting material. Too much will ruin the motor, but it would need replacement otherwise anyway. This has worked on Pioneer PDM series spindle motors. I have heard of people using carburetor cleaner successfully but I would recommend something a little less harsh to start. Contact, circuit board, or tape head cleaner may work.
    Another technique is to disconnect the motor completely from the electronics and power it for a few seconds in each direction from a 9 V or so DC source. This may blow out the crud. The long term reliability of both of these approaches is unknown. WARNING: Never attempt to power a motor with an external battery or power supply when the motor is attached to the circuit board - you may blow electronic components on the circuit board and complicate your problems. Disconnect *both* terminals and label the wires or motor orientation so you can reconnect it with the proper polarity. It is sometimes possible to disassemble the motor and clean it more thoroughly but this is a painstaking task best avoided if possible. If you do manage to revive it, also see the section: Spindle motor drive modification to minimize chances of future problems.

    Replacement motors

    The spindle motor should be replaced with an identical unit though it doesn't have to be the exact manufacturer's part number - universal substitutes are often available at a much lower price.
    However, there may be alternatives for other types. Most of the other small PM motors found in CD players and CDROM drives (as well as VCRs and other consumer electronics and small appliances) are basically pretty similar. The important differences are mainly mechanical - size, mounting, shaft length, etc. There may be variations in nominal voltage and current usage but for non-critical applications like drawer loading or disc changing, if you can make a generic replacement fit the space and attach to the drive components, There is a good chance that it will work well enough. Such replacements may be available from companies like those listed in the section: Recommended parts suppliers. Check a few catalogs!

    Motor bearing problems

    A dry or worn bearing can make the motor too difficult to turn properly or introduce unacceptable wobble (runout) into the shaft as it rotates.
    Feel and listen for a dry bearing: The shaft may be difficult to turn or it may turn with uneven torque. A motor with a worn or dry bearing may make a spine tingling high pitched sound when it is turning under power. A drop of light machine oil (e.g. electric motor oil) may cure a dry noisy bearing - at least temporarily. For spindle motors (these are the only motors in CD players where runout is critical), try wiggling the shaft from side-to-side - any detectable movement is an indication of runout. At some point, this will be bad enough such that the focus and tracking servos will be unable to compensate for the runout and audio noise and skipping may result. Some oil may help but a spindle motor with a worn bearing will require replacement eventually. Furthermore, it may prove impossible to reach the bearing(s) to lubricate them properly. See the section: Spindle motor problems for more information.

    Spindle motor problems

    The following are some indications that the spindle motor may be defective or need attention. However, insufficient spindle motor voltage or current could also be due to spindle motor driver faults, incorrect power supply voltages, or logic problems.
    Note: If the disc doesn't spin at all, try rotating it by hand while it is trying (or with the servos enabled if it has a TEST mode). If you hear that 'gritty' sound, the focus and probably tracking servos are working but the spindle motor or driver are faulty.
    • Focus is successful but disc does not spin (dead motor or dead spot on motor, shorted motor, bad connection).
    • Disc spins but at too slow a rate or is erratic or needs some help (weak motor or dead spot). Reading of disc directory may be erratic. (Try helping motor out by hand).
    • Voltage across spindle motor is only 1 V or less while attempting to spinup and read the directory and climbs to 5 V or more with the motor disconnected (partially shorted motor).
    • Spindle bearing runout is excessive (i.e., detectable by wiggling the spindle from side to side) or spindle motor bearing is dry or tight (try lubricating if possible).
    • Repetitive noise or dropouts at the disc rotation frequency or twice the disc rotation frequency. This may get worse toward the end or outer tracks of the disc. (Excessive spindle bearing runout or bad windings).
    Check the motor before replacement (see the section: Small motors in CD players for general motor problems and testing). You should be able to easily confirm or eliminate the spindle motor as the cause of your problems. If either of the cleaning or rejuvenation techniques make a significant difference in performance, then the motor is almost certainly at fault. If the player now functions normally - leave it alone or, perhaps, try the circuit modifications suggested in the section: Spindle motor drive modification to minimize chances of future problems. The spindle motor is often blamed for everything from long distance skipping (coarse tracking problem) to disc spinning too fast or in wrong direction (a control problem). Spindle motors do fail but they are not at the root of all problems. If you suspect a dry or bad spindle motor bushing (bearing):  

    A little trick I came up with when my Sony CDP-550 player started skipping: Tape a coin (a penny seems to work fine) to the top of a CD that skips. If it cures the skipping, then the problem is likely the spindle motor bushings need lubricating.

    Spindle motor drive modification to minimize chances of future problems

    This suggestion is directed toward Pioneer players of the PD and PDM series with known common spindle motor problems. It may apply to other Pioneer models and other brands as well. It can be used whether you have just rejuventated an existing motor or installed a replacement.
    For Pioneer players, there is actually a circuit modification to reduce the possibility of repeat problems but it requires changes to the wiring - cuts and jumpers - which I prefer to avoid. My recommendation is to try the following which can usually be added at the motor terminals. (I have not done this yet, so no guarantees): Put a series string of 4 1N400X diodes in parallel with another similar string in the opposite direction across the motor terminals. This will limit the maximum voltage to about 3 V instead of the 6 V or more that it is now. The reduced voltage should reduce chance of damage to the commutator at spin-up. On the Pioneers at least, the motor driver should not mind the extra load during any peaks where the diodes kick in. It may take a couple seconds extra to start up but I believe it will still work fine otherwise. If you do this, let me know how it works.

    Spindle motor replacement

    Mark the height of the old spindle platter before you attempt to remove it. The best approach is to make a shim that will fit between the bottom of the spindle platter and the motor as a stop. The height is usually specified to a precision of 1/10 of a mm. Too low or too high and the disc may rub. This is probably overhill - 1/2 mm is probably good enough but try to get it as close as possible. The focus servo offset adjustment will make up for any height error in so far as focus is concerned.
    The spindle is often press fit and difficult to remove without damage. It is critical that when the spindle is replaced, it be mounted perfectly with no wobble. If you can obtain a new spindle platter with the new motor, this is the best option. If not, take every precaution to prevent damage to the spindle platter during removal - even it it means destroying the old motor in the process. See the section: Spindle platform pulling. When press fitting the new spindle, the use of an arbor press or drill press is highly recommended. Put a block of wood under the bottom of the motor and your previously made shim between the spindle platter and the motor. Press straight down - slowly and firmly. Err on the side of being to high and check the height. Repeat until you get it perfect. It is much easier to press a little more than to raise the height if you should go to far. If there is a set screw, your job is much easier. Other mounting schemes may be employed - use your judgement in replacement procedure. For non-press fit installations, a drop of loctite or nail polish will reduce the chance of it working loose. The new motor may come with a shim to set the proper height or it may be included as part of the player: Note that the precise length of the spindle motor shaft may be critical on some CD players to help center the disc. Thus, when you order a replacement, don't assume that a slightly shorter shaft will be adequate just because it will hold the platter securely - check it out first. (From: Mark Z.) Most Pioneer models have a spindle height jig molded onto the subchassis. It snaps off and slips between the disc table and motor base to set the height.

    Unknown spindle platter height when replacing spindle motor

    What was your excuse for not marking it? Oh, an elephant sat on the player and that is why the motor needed replacing but the height was already messed up :-).
    If the player operates normally after spindle motor replacement, as they say "If it works, use it". I wouldn't worry about it. The focus servo has a wide range. If you are curious, try to locate the test point for focus error. It should probably be a noisy waveform centered around zero volts. However, this may not be the case and you would need the service manual to be sure of what it should be. As long as the player seems to locate the disc directory quickly and plays normally, leave it alone! However, if it now has problems either taking a long time to start play or exhibiting unusual noise or skipping during play, you should probably try to obtain the spindle platter height specification and set it more accurately. I definitely would not recommend mucking with the spindle platter height unnecessarily if it is a press-fit. You would probably end up with a bent shaft and need for yet another replacement motor. However, if the spindle platform is secured with a set screw, you can try to adjust it to minimize focus error and/or optimize playback performance.

    Spindle platform pulling

    I was able to remove the spindle platform on a Philips CD pickup using the lawn mower engine flywheel pulling approach - levers under both sides of the platform so the pressure is upwards and not sideways while tapping on the center of the shaft with a thin punch. Thus, there was no shaft bending. I believe that the motor survived without damage.
    I was actually going to 'machine' a mini-flywheel puller but then I said: "What the heck, that is too much work :-)". In any case, the spindle platform is completely undamaged and the motor could probably be reused. However, be careful what you are prying against - the mounting may use tiny screws into plastic or something equally fragile. Of course, if you plan on doing any serious hammering, remove all the delicate optical and electronic components first! If you are a purist and want to build a mini-flywheel puller, it's easier than you might think using only common hand tools are required and some scrap metal. Don't try to copy a real flywheel puller. All it takes are the following: (Suggestion and photo from: Anders Gustafsson).)
    • A "pusher" screw with about 1/4" of its end ground down to be slightly narrower than the diameter of the spindle table hole. This then pushes against the spndle shaft. Alternatively, drill a hole in the end of a screw to accept a steel pin of the appropriate diameter.
    • A thin plate slightly larger than the spindle table with a slot cut in it so it can be slipped between the spindle table and motor.
    • A thicker plate of similar size drilled and tapped in the center for the pusher screw.
    • Two or three spacers of some sort to hold the two plates at a fixed distance.
    A photo of a typical finished puller is shown in Home-Built CD/DVD Spindle Table Puller. Of course, the plates don't need to be circular, whatever is convenient to fabricate given your resources.

    Correcting spindle platform wobble

    This assumes the bearings are in good condition but the shaft has somehow gotten slightly bent. You might ask: How could this happen? Once cause could be using an improper technique to remove or attempt to remove or install the spindle platform from/to the motor shaft or something heavy falling on the player. Right, I know; in this case, a bent shaft will likely be the least of your problems! :-)  

    I use something as simple as a pencil. Start the motor going and put the pencil right above - but not touching - the part that is bent. Now move it in tiny increments towards the bent part. When you hear the first tiny "scrape", stop the motor and note where the pencil mark appears. This is the place you want to press down to even it out.
    This is loads of fun with a CD spindle motor and sometimes it's just easier to get a replacement. Trust me.

    Sled motor problems

    The following applies to sled positioners using conventional permanent magnet motors with the typical gear or screw mechanism. (Those using linear motors use closed loop servo systems with a drive coil and sense coil. About all you can do to test these without a schematic is to check for continuity of the two coils.)
    Sled motors tend to be less likely to fail than spindle motors but can suffer from similar afflictions. The following are some indications that the spindle motor may be defective or need attention. However, insufficient sled motor voltage or current could also be due to sled motor driver faults, incorrect power supply voltages, or logic problems. These problems could also be of an erratic nature if the motor has a dead spot or is partially shorted. The sled motor (or its driver and associated circuitry) may be at fault if:
  • The sled fails to reset to the inner track.
    • Focus is established and the disc begins spinning at the proper speed for the current pickup location but the pickup fails to move to the selected track location.
    • There are problems with discs repeating more-or-less the same musical segment every few seconds (the sled gets stuck) or long distance skipping (the sled sticks but then once enough of a fine tracking error develops, breaks free and overshoots the proper location).
    The motor may have a dead or weak spot in its rotation. Rotate it by hand 1/4 turn or so and see if it now spinds normally or a fraction of a turn. See the section: Testing of motors. Of course, any of these could also be due to mechanical problems as well so eliminate these as possibilities first.

    Sled motor drivers

    The sled motor may actually receive its drive from two sources (maybe more) as shown conceptually in the diagram below. These may or may not be separate physical outputs tied together:
                                    Slew+ o--------+
                           |\                      |
              Tref+ o------|+ \                    |
                           |    >------------+     |
                        +--|- /              |     |    |\  Sled Drive
                        |  |/ TE+ Comp       |     +----|+ \  
                        |                    +----------|+   \ 
     Tracking Error o---+                               |      >--------o + Sled
                        |                    +----------|-   /      +---o - Motor
                        |  |\ TE- Comp       |     +----|- /       _|_
                        +--|+ \              |     |    |/          -
                           |    >------------+     |
              TRef- o------|- /                    |
                           |/                      |
                                    Slew- o--------+
    
    
    1. Slew driver - this is used when the pickup is resetting or moving across the disc. The motor is commanded to move smoothly in either direction or is searching for the general vicinity of the starting location (time code). Where the pickup is unable to reset to the inner track or unable to move to an outer track during seek operations, a part of this driver or its associated circuitry may be at fault.
    2. Coarse tracking driver - this is used to move the sled a small amount during play to recenter the pickup once the fine tracking error exceeds a threshold. Many designs will do away with explicit comparators (as shown above) and just use the friction of the sled motor/mechanics to result in movement once the voltage on the motor becomes large enough. This would seem to waste power, however, and be undesirable for battery operated portables, at least. Where the seek operation completes normally and the music starts playing but then gets stuck or jumps back and repeats after a few seconds, the coarse tracking driver or its associated circuitry may be at fault.
    Any of these symptoms may also be caused by a defective sled motor or mechanical problems - probably more likely than bad electronics.

  • Notes on Specific Equipment

    Pioneer PD/M series players/changers do not recognize discs 


    Where a Pioneer player or changer does not recognize discs, the most common causes are:
    1. Partially shorted spindle motor due to 'crud' on commutator. Cleaning may be possible. Generally, disc will spin but at insufficient speed. Try TEST MODE toward latter (outer) part of disc as the required rotation rate is lower and/or check voltage to motor, below. See the section: Reviving a partially shorted or erratic PM motor.
    2. Cracks in flex cable to optical pickup assembly - replacement of flex cable will be required. This may also result in erratic operation while playing. The Pioneer replacement part number for the improved version of one common cable is PNP-1343 but confirm this is correct for your model before you order. Sometimes, the flex cable is just not positioned properly (clear of the metal cover) and just needs to be 'adjusted'.
    3. Collapsed rubber suspension grommets. There may be a scraping or clicking sound associated with this failure. For changers, gently lift up on the optical pickup assembly while the disc is attempting to spin to see if the disc is recognized and will play. Replace the deteriorated grommets.
    4. Lens fell out. This is somewhat unusual except mostly for changers (possibly only those made by Pioneer) where the pickup is mounted upside-down, but apparently the adhesive dries out and may fail completely during use or as a result of the player being moved. See the section: Objective lens popped out. Note: If you do attempt to reattach the lens, replace the rubber grommets as well as collapsed rubber grommets are common on these pickups - and may even have been the cause of the lens problems (disc contacting lens).
    For general information, see the sections starting with: "Startup sequence".

    Pioneer PD/M series test mode

    The TEST mode available on some CD players is extremely useful for narrowing down problems. The following are for the Pioneer PD/M series of CD players and changers:
    • To enter TEST mode, press the TEST button while turning POWER ON and then hold it on for at least 1 second.
      • Some models only have a set of contacts - Pioneer saved 2 cents on a switch! Short between these with a piece of wire or a paper clip instead of pushing the button.
      • On players with a standby mode (not a hard on/off switch), plug the unit in while pressing the TEST button or shorting the contacts.
      The TEST button or contacts are located on the main board (usually near the front right corner - may be obscured by cables).
    Once TEST mode is engaged, the servos can be controlled from the front panel:
    • STOP turns all servos OFF.
    • TRACK FWD (>>|) enables FOCUS servo (and loads disc 1 in changer).
    • PLAY enables SPINDLE servo.
    • PAUSE enables TRACKING servo.
    • MANUAL SEARCH FWD (>>) or REV (<<) to move the optical pickup.
    Depending on model, the specific functions and behavior of the front panel buttons in TEST mode may vary slightly. Some may use PROGRAM to turn on laser, PLAY to enable focus servo, second push of PLAY to enable tracking servo, etc. You may have to experiment. WARNING: Normal safety checks are disabled in TEST mode. Thus, the laser may remain on as long as focus/tracking/spindle servos are engaged even if no disc is in place. Take care. Power cycle (by unplugging if necessary) to return to normal mode.

    Pioneer spindle motor voltage (operating normally)

    Here are the typical measurements for the PD/M series players:
    • Spinup: >2.5 V.
    • Time to lock (est): 1 to 2 sec.
    • Start of disc (500 rpm): 1.0 V.
    • End of disc (200 rpm): 0.5 V.

    Pioneer spindle motor problems

    When bad, spindle servo drive tops out at 0.6 V and 100 ma. Player is unable to spin up to required 500 rpm to read disc directory.
    While exact cause is unclear, theory is that large voltage applied at startup followed by long periods of very low voltage (.5-2 V) operation allows conductive crud (carbon) to build up on commutator eventually reducing resistance to the point where the driver cannot apply enough voltage to achieve 500 rpm. A short squirt of degreaser through motor access hole had an immediate dramatic effect returning operation to normal. It is not known how long this will last. (Also see the alternative procedure in section: Reviving a partially shorted or erratic PM motor.) Collateral symptom: Spindle motor servo drive IC becomes quite warm when attempting to power shorted motor. However, it does not appear to be harmed. Use TEST mode to play disc at outer track. If this is normal, then spindle motor is probably bad as the rotation speed at the outer tracks is less (200 rpm) and a partially shorted motor may still run fast enough for this.

    Pioneer PD/M series servo adjustment procedure

    The following procedure assumes that unit is functional but internal controls may have been moved from their correct position. This procedure has been determined experimentally and is subject to change without notice. If you have not touched the internal controls, there is no need to perform this procedure. Use techniques and observations discussed elsewhere in this document.
    A number of Pioneer CD players have used very similar designs. However, technology sometimes the implementation changes dramatically between units with virtually identical model numbers. It is known that this adjustment procedure applies to many older Pioneer single disc players (e.g., PD5100) and magazine changers (e.g., PDM400/500/600 etc,). However, newer models that appear virtually identical to these may require a totally different adjustment procedure. Therefore, use at your own risk! With minor (and obvious) modifications, this general approach should also apply to many CD players from various other manufacturers as well. I also recommend you read the section: General servo adjustment procedure in its entirety before proceeding to tweak your Pioneer player. Assumptions:
    • Controls on the main board have been moved or are in an unknown state but not on the flex-cable or optical pickup assembly.
    • The player is otherwise functional - no physical damage.
    And now for the fun:
    1. Set all the main board controls to their midpoint.
    2. Power up the unit in TEST MODE (hold down the TEST button while powering on.
    3. Adjust TR.BAL (Tracking Balance) to the center of the range over which the sled remains stationary. Outside this range, the pickup will slew to one end or the other.
    4. While monitoring TP1-6 (FO.ER, Focus Error) with a VOM or DVM, adjust FO.OFS (Focus Offset) for a reading of 0V +/- 10 MV. Note: I have found that on some players, this may not actually be quite optimal and fine adjustment be beneficial.
    5. While monitoring TP1-2 (TR.ER, Focus Error) with a VOM or DVM, adjust TR.OFS (Tracking Offset) for a reading of 0V +/- 10 MV. Note: I have found that on some players, this may not actually be quite optimal and fine adjustment be beneficial.
    6. Load a magazine with a disc in slot 1 and press >>|, TRACK SEARCH Forward. This should load the disc and enable focus servo.
    7. Use MANUAL SEARCH REV (<<) to position sled at beginning of disc.
    8. Press PLAY. This enables the spindle servo. Disc should now spin up and lock at at around 500 rpm. If disc does not start or appears not to reach correct speed, check voltage on spindle motor. It should be greater than 2.5 volts during spinup. The most common cause of low voltage is a dirty partially shorted commutator/brush assembly inside the motor; clean or replace as necessary. WARNING: if the disc spindle speed runs away, turn power off and wait for spindle to stop completely. VCO control may be set to high; turn counterclockwise 1/4 turn and start from the beginning.
    9. Press PAUSE. This locks the tracking servo. The display should show the disc TRACK and TIME. Alternately pressing >> or << should move pickup, then press PAUSE to start play again. Audio will be correct at output. Correct display and sound only near end of disc indicates a spindle motor unable to achieve sufficient speed (see above).
    10. Adjust the VCO control to the midpoint of range in which disc plays correctly.
    11. Set RF.OFS to the midpoint of the range over which play continues normally.
    12. Set FO.GAIN to midpoint of range over which it locks. CAUTION: the disc may enter a runaway state if you go to far. Check at both the beginning and end of the disc. FO.GAIN may need to be increased if the player is overly sensitive to bumps or disc wobble. It may need to be decreased if sensitivity to disc defects is too high.
    13. Set TR.GAIN to the midpoint of range over which it locks. CAUTION: the disc may enter a runaway state if you go to far. Check at both the beginning and end of the disc. TR.GAIN may need to be increased if the player is overly sensitive to bumps or disc wobble; it may need to be decreased if sensitivity to disc defects is too high.
    14. Press STOP. The disc should unload. Exit TEST MODE by turning power off and on again. Confirm that the disc loads properly and that the directory comes up quickly and the music starts without excessive delay, hunting, or hesitation.
    15. Test forward and reverse search and seek functions for proper behavior. Some slight adjustments to tracking balance or fine tracking offset may be needed to equalize the forward and reverse search or seek speed.
    16. The player should now operate normally. However some tweaking of the gain controls may be necessary (as described above) for optimum defective disc and track seek performance over entire disc.
    If you have an oscilloscope capable of at least 5 MHz bandwidth, you can now optimize the amplitude and stability of the 'eye' pattern at the RF testpoint by going back and touching up the various offset (RF, focus, fine tracking) adjustments. Unless otherwise instructed by the service manual, it is probably safe to assume that the RF signal should be maximum when everything is properly adjusted. For example, if TR.OFS is not set properly, you may find that the RF signal amplitude *decreases* when the tracking servo is closed since the laser beam is now consistently off-center with respect to the row of pits and lands. (With the servo loop open, the beam was crossing tracks more or less at random so it was sometimes centered!) For the Pioneers I have seen, it appears that the FO.OFS and TR.OFS may *not* be set optimally by the static adjustments (4) and (5), above.

    Pioneer 6 disc cartridges (magazines)

    There are usually pretty robust but if something was forced, in addition to damaged plastic parts, a bunch of steel balls (about 1/8" diameter) may escape. DO NOT attempt to use the cartridge without these - they are part of the mechanism which assures that only one tray will come out at a time. If they are missing, as one tray is pulled out, another may come along and jam up the works. :( I believe there are 5 total (for a 6 disc cartridge) and you need every one of them! Assuming there is no actual damage, it is possible to reinstall the balls by carefully disassembling the cartridge. If I recall correctly, they go in a channel formed by a hole on each tray next to the hinge and a spring holds them in place. Buying a new cartridge may be the way to go. :)

     Pioneer CD Player Adjustments 

    There are a lot of adjustments that must be done per the service manual, but the guide is much easier to follow.
    1. Grating.
    2. Tangential tilt.
    3. focus offset.
    4. tracking offset.
    5. focus gain.
    6. tracking gain.
    The spindle motor height is also extremely critical in these older Pioneers. Recommend you get the correct one. If it has the old white flat cable going to the optics it also must be replaced, the white ones would go bad and intermittent. If the lens fell out, the 4 rubber grommets must also be replaced. We typically reglue the lens on very carefully (works about 75% of the time), replace the rubber grommets, check the spindle motor, and do the adjustments to fix ones like these. (From: Mark Z. and Sam.) There is a solder short on replacement pickups that needs to be removed before installation. I think it is on the flat wire which plugs into the circuit board. The grating adjustment is the most critical and requires an oscilloscope and some care to avoid physical damage. What looks like an adjustment potentiometer is actually a small slider to be actuated only a small amount one way or the other by your screwdriver. Turn it like a pot and it falls apart. Learned this one the hard way! The adjustment procedure in the old manuals was a bit of "purple magic". After all what is a "smooth null" in the waveform anyway? Fortunately it's really easier than that... In test mode, and with the disc spinning, servos open, and observing the RF (HF) pattern, adjust the eye pattern for max, then press the Pause button to close the tracking servo. If the adjustment is off, the size of the waveform will drop. Re-adjust a bit to one side or the other until the size of the waveform is the same whether the servo is closed or not. This is how the Pioneer guys do it (or did anyway before they all got laid off).

    Pioneer PD-7010 adjustment procedure (from Davidson)

    Note: See Pioneer TEST mode description in the section: Pioneer PD/M series test mode.
    1. Laser Power - Normal mode. Press PLAY - Laser power should be set to: .26 mW +/- 0.02 mW. Adjust VR1 to spec.
    2. PLL VCO Free Run Frequency:
      • Set the player to TEST mode.
      • Press STOP to switch all servos off.
      • Press TRACK FWD to enable the FOCUS servo.
      • Press PLAY to enable the SPINDLE servo.
      • Observe the waveform at pin 8 of IC8 (2/2) using a scope set to 0.5 V/div. This waveform can be found easily at the legs of C47. Note the center value of this waveform.
      • Using a core driver, adjust VL1 (VCO coil) so that the center value of this waveform is the same when PAUSE is pressed to switch on the TRACK servo.

    3. Tangential Adjustment:
      • Enter TEST mode and load the TEST disc??
      • Use the MANUAL SEARCH FWD key to put the pickup at the end of the disc.
      • Press TRACK FWD, PLAY, and PAUSE in that order to enable all servos.
      • Use the Scope to observe TP2, Pin 4 (RF Output). Adjust the Tangential Adjustment Screw to obtain the clearest eye pattern. This is the midpoint between the places where the pattern begins to deteriorate.

    4. Tracking Offset and Focus Offset:
      • Enter TEST mode.
      • Adjust the voltage at TP1, Pin 9 TR (Tracking Return) to 0V +/- 10 mV by turning VR2 (Tracking Offset).
      • Adjust the voltage at TP1, Pin 3 FO.ER (Focus Error) to 0V +/- 10 mV by turning VR6 (FO.OF, Focus Offset).

    5. Focus Gain:
      • Enter TEST mode.
      • Press STOP to disable all servos.
      • Adjust the frequency and output voltage of CH1 of the F.T.G. to 878 Hz and 0.2 V P-P. What if I do not have an F.T.G.?
      • Connect the F.T.G. adjuster. Right :-).
      • Press TRACK FWD, PLAY, and PAUSE in that order.
      • Adjust VR3 FO.GA so that the green LED just comes on. Right.

    Alignment after replacing Pioneer optical pickups

    Unlike Sony pickups, which are aligned at the factory and then sealed with something like hot-melt glue to prevent tampering, Pioneer pickups require alignment, possibly even before a disc will be recognized. I wonder whether this is just due to cost cutting (but how could they even test the pickup?) or they just feel that it needs to be matched to the CD player....
    Both optical alignment of the pickup itself and then possibly servo adjustments will be needed. I have done these adjustments without the service manual using just an oscilloscope and a music CD (no test disc) on an existing pickup (not a replacement) by basically maximizing the amplitude of the 'eye pattern' but the proper equipment and documentation would help!
    Pioneer pickups are shipped unadjusted. Some of the newer models happen to work without additional adjustment but not all of them. Unfortunately some of the service manuals OMIT the final adjustment on the grating. One should adjust for a smooth null THEN for maximum output with a slight adjustment either clockwise or counterclockwise depending on whether the pickup is upside down or not. I can never remember which. I have seen at least a couple Pioneer manuals where the adjustment instructions END with the reference to the "smooth null". Frustrated technicians result because they think they've done what the instructions say, which they have - they just didn't get a full set of instructions. This is a common discussion point at Pioneer training schools.
    Radial and tangential adjustments must be done first. These are the metal screws visible through the pickup PC board. Have a scope on the RF test point and adjust each for maximum while playing a disc. Some discs may work better than others during initial adjustments. If you're lucky you may not have to adjust the grating after the other are done. The older Pioneers' pickups were shipped with the tangential adjustment ALL THE WAY to one side. This applies ONLY to the older ones with the mainly metal chassis. It was a white nylon screw which jammed the underside of the spindle motor mounting plate, and actually prevented the pickup from moving on its' track until loosened. On the newer models, there are radial and tangential adjustments which can be adjusted in test mode. Both older and newer ones have grating adjustments, but the newer ones don't generally need adjusting. Don't get into grating adjustment unless you really have to.

    Pioneer pickup replacement saga

    As a guy around here had problems with his Pioneer PDS-501 CD player, he asked me if I could help him to fix it. Ok, I thought, just a cd-player, probably a bad spindle-motor or a dirty lens. Well, I sure got a surprise after taking away the cover. I heard something's gone loose somewhere into it and soon I noticed the lens on the pickup had popped out. I spoke to the owner and he told me to change the entire pickup, as he didn't wanted to throw it away yet. Said and done. The new pickup were easily changed, about 10 minutes or so. Time for the first test. I suspected nice music streaming out of the player, but unfortunately all I could hear was: Sccchhh, stk, stk, stk... And off it went. What the heck! It didn't even recognize my test CD! The display showed all zeros. I started to check for bad connections. Didn't find any. Didn't find anything unusual. Hmm....
    After several days of investigation and a new spindle-motor, no improvement. I felt real stuck. Until I got a tip (from here) that they solder a jumper on the flex cable to prevent damage to the laser diode until the pickup is installed. OK, I threw myself over the player and unsoldered the jumper. Hopefully testing again: Sccchhh, stk, stk, stk... Off! God, what's wrong? After several hours of thinking I noticed that the pickup were not in horizontal position. I adjusted it for a proper position. Testing again... Scchhh, stk, stk, stk.. After this I realized that new Pioneer pickups come totally unadjusted from the factory. After adjusting the grating, I made the player able to recognize CD's again and even play them! So, be awake when changing a Pioneer pickup, cause they'll not make it easy for you!

    Sony KSS240 optical pickup adjustments

    The functions of the pots on the pickup itself (from left to right): Focus, Tracking, Laser Power. (This determined from one sample. I don't know if all revisions are the same!) See other sections of this document for adjustment procedures. DO NOT touch laser power except as a last resort.

    Yamaha CD3 adjustment procedure (from Davidson)

    1. Laser Power:
      • Remove the flapper.
      • Player should be in focus search mode.
      • Short terminals FD1 and R together.
      • Laser power should be 0.24-0.30 mW. (Apply -9V +/- 0.5 V if the pickup is off the circuit board.)

    2. HF Level:
      • Monitor HS with scope. Peak to peak level should be between 1.5 and 2.5 V.

    3. Focus Offset:
      • Set the TEST disc to PLAY. Make the adjustment at the center of disc rotation (35 DHS).
      • Connect the oscilloscope to HS. Adjust VR101 for the best eye pattern.

    4. Tracking Gain:
      • PLAY mode.
      • ACVM to terminal Q and VE.
      • Apply 800 Hz, 100 mV rms to TD1 and GND with a 220K resistor in series from the audio oscillator.
      • Adjust VR104 so that ETE = (EQ + 5 dB) +/- 1 dB.

    Audio whine (not from speakers) and/or muddy sound with Sony CD players

    Generally, the only symptom is a CD players that sounds unhappy - there are no audio or tracking problems. However, in severe cases, there may also be audio degradation described as "muddy sound".
    (No doubt, a non-Sony approved weight would work equally well for the solution below.) (From: Lance Edmonds (lanceedmonds@xtra.co.nz).) The whine problem usually occurs with KSS240A and KSS213A optical pickups, and is caused by a mechanical resonance. There are at least 2 service bulletins describing the fault and the cure. Sony sells a special weight to fit to the pickup, and also a felt pad to add to the bottom of the top clamp assembly. Both these items cure this problem. Some machines may only require the weight. In rare circumstances the resonance can interfere with the tracking/focus servos enough to cause skipping. Usually the problem is not easily repeated, however certain light weight disc's may trigger the problem repeatably. Note that the resonance usually only occurs on the first few tracks if at all, and some disc's will play with the problem never showing up. Seems to be a disc weight/thickness/density problem. (From: Tim Schwartz (toschwartz@worldnet.att.net).) Sony had a problem with the KSS-240A optical pick ups having an oscillation problem, usually 800 Hz, and it can be so loud that it causes the unit to start skipping. Sony had a cure of adding a brass weight to the optical pick up, and a felt washer to the clamper. I'm not sure it this applies to all application of the KSS-240A or not. From a Sony Technical News bulletin that I've got a faxed copy of, the weight is part number 4-962-979-01, and the screw to attach it is 7-685-134-19. The screw replaces the one holding the PC board with the pots to the laser. The felt washer is 4-986-769-01, and goes on the surface of the clamper that touches the disc. The machines that show this do not do it on all discs, and it seems to be the worse 5-12 minutes into the disc. Please be aware that original Sony KSS-240A lasers have 3 pots on the PC board, a cable connector with a clamp, and that the chip on the bottom is 14 (or is it 16) pins. There are many 'after market' lasers sold as KSS-240A that have a single pot, no clamp on the cable connector and an 8 pin chip.

    The vibration from the spindle motor sets up a resonance in the pickup. You can see it in the focus error and tracking error waveforms. Lowering the tracking or focus gain a bit can help also, and adding some silicon sealer or RTV where the spindle motor contacts the BD board.

    Notes on Sony CDU31/33A CDROM drives

    (Refer to the photo of the Sony CDU-31/33A CDROM Optical Deck for parts identification.)
    Both these drives use similar optomechanical technology. The CDU31A is 1X (though I have heard that some versions of this may be 2X, unconfirmed) and CDU33A is 2X. Many have complained about the lack of a motorized tray. What this does provide is a very simple robust mechanical design. A solenoid latch keeps the drawer shut. When the solenoid is activated (or the emergency release is pressed) the drawer pops out about an inch. Pulling the rest of the way is manual. The movement of the drawer clamps/unclamps the disc to the spindle with a powerful magnet. Except from gross abuse, there is little to go wrong mechanically. There are only two major components: the Printed Wiring Board where all the active electronics are located and the Optical Deck including laser, optics, and pickup worm drive mechanism. The other parts include the upper plastic casting and metal shroud, solenoid latch assembly, right and left guide rails, drawer assembly, and front bezel, two springs, bottom plate, 6 screws. There are only two electrical connectors inside: one flat printed cable linking the PWB and optical deck and a two pin connector supplying power to the eject solenoid. This is in pleasant contrast to some other CDROM drives I have seen with a half dozen or more small connectors spread all over the PWB making removal and testing very difficult and risky.

    Disassembling the Sony CDU31/33A CDROM drive

    The only major cautions are to not lose any of the small screws or springs and to avoid damaging the multi-conductor flexible cable linking the electronics to the optical assembly.
    The following procedure takes about 5-10 minutes:
    1. Place the unit upside-down on a soft surface.
    2. Remove 4 philips head screws securing bottom cover. Set bottom cover aside. You will now have access to the electronic adjustments for focus, tracking, etc. If this is what you are after, no further disassembly is needed.
    3. Unclip the front bezel. Slide it out with the tray as far as it will go. You may need to manually activate the eject mechanism with a paperclip.
    4. Remove 2 philips screws securing Printed Wiring Board (PWB). Gently lift PWB and disconnect connector to latch solenoid assembly in front of unit.
    5. Gently lift PWB further and disconnect flexible cable connector on optical assembly. Mark the orientation so there will be no doubt about getting it correct if you need to reassemble on the workbench for testing. There is a latch at each end which you push away from the connector 1 mm or so. The cable will than come out easily. You now have partial access to the optical assembly sled drive. Cleaning and lubrication of these components is now possible.
    6. Lift the latch solenoid assembly up, remove and set aside.
    7. Using a pair of fine needlenose pliers or tweezers, disconnect and set aside the two tray retraction springs. Note their position and orientation.
    8. Remove the two plastic guides - one on each side. There are little tabs that you will need to depress and then lift each guide straight up.
    9. The entire deck can now be slid forward and lifted off. The opto/mechanical assembly can then be removed from the tray. Set the tray aside. The mechanism shown in the photo of the Sony CDU-31/33A CDROM Optical Deck is screwed into the rubber shock mounts.
    10. If you prop up the PWB and reconnect the flexible cable - note the orientation marks you made previously - you can then run the drive with full visibility of the mechanism and optics. With a CD in place, there is no danger to you from the laser beam. Just make sure the PWB cannot short to anything and that the whole affair cannot tip over.
    Reassemble in reverse order. Be especially careful reinstalling the flex cable. Make sure no wires are being pinched and that nothing is obstructing free movement of the optical pickup. This is actually pretty easy for this drive.

    Sony Playstation (and other game machine) problems

    The following information applies directly to the Sony Playstation but other CD/CDROM based systems use similar technology.
    Note that the Playstation (and other newer game machines) are programmed to only work with discs released for the same country or general geographic location in which it was purchased. Thus, if you got a good deal on a used system, you may now know why: it might only work with Japanese software! :-(. I believe Sony has a flat rate ($100 or so) repair fee for these - probably toss the guts and replace them - but this is barely justifiable for a $200 system. Many complaints are similar to the following with symptoms of marginal play of audio or game discs, skipping, erratic operation, etc. Other service centers have both cheaper and DIY kits for Playstation repair. For example, VDO Specialties advertises a $45 flat rate and also sell a repair kit they say will handle loading, skipping, and other optical pickup problems. I have no idea of its price or whether these claims are accurate.

    Playstation appears dead 


    Quick test for symptoms of no power:
    With the Playstation top cover off and no CD installed press down on the door switch. What should happen is the CD will not spin, but the laser pickup should move up and down attempting to focus on a CD. WARNING: Laser is exposed - don't stare into it! See the section: SAFETY. --- Sam. If the above does not happen the following problems may exist, in order of probability:
    1. Door switch broken
    2. No 8 VDC to CD, usually a blown ICP "fuse" on the motherboard, or bad power supply.
    3. CD controller toasted (bad)

    PSX controller unreponssive 

    General problems reading PSX discs

    "I have a Sony Playstation, it starts up OK as in power-up etc. But, insert a disk and it does not seem to want to read the TOC. The disc spins up to speed and the laser goes through the motions of focusing, but then zilch, nada, no-zinks! Funny thing is it seems to play audio disks correctly, but not Playstation game disks"
    Of course, first clean the problem discs and lens. See the relevant portions of this document for instructions and other general troubleshooting tips. All the usual problems of normal CD players and CDROM drives apply. Note that in general, it may be possible to play music discs with few or no problems and still not be able to reliably play games (or as applied to CDROM drives, reliably access data). Readout of programs and data must be totally error free while errors can be tolerated for audio tracks with little or no detectable degradation in sound quality. Another reason is that audio is always read at the 1X rate; the system may be more tolerant of a marginal disc or servo alignment at the 1X compared to 2X or higher rate. Some of these problems may actually be a result of poor design due to extreme and unacceptable cost cutting on Sony's part. After all, the Playstation reader is essentially the same as a 2X CDROM drive - which should be mature technology by now!

    A common problem on Playstations is the lens 'sled positioning' assembly. The lubricant that they used on this gets 'a little' solid.
    Solution: remove old lube (all the way back to the motor worm gear) and use a long-lasting lubricant. I use a mixture of tri-flow and graphite grease. This seems to cure the problem. Apparently what happens is that the CPU requests a read of a certain sector of the CD, and the sled can't get the lens to the proper location quickly enough.

    There are many machines out there with similar problems to yours. This is usually caused by a laser servo that has been badly set up. The symptoms are jumping and/or skipping on the FMV (full motion video) intro sequences and jumping and/or skipping on the music. In the worst case, certain gold (CD-R) discs will not boot. The pits on CD-R are never as well defined as a pressed disk resulting in around a 1/4 to 1/2 volt reduction in the RF eye pattern.
    The problem can generally be cured by carefully adjusting the bias control on the main board near the laser ribbon connector. turn this a little bit clockwise or counter-clockwise until you have decent results. when you are happy leave it alone. It can be tempting to keep adjusting for different disks trying to get it spot on. There are not many machines that will play every single gold disk perfectly. Most will skip and jump occasionally no matter how carefully they are tweeked. DO NOT touch any other adjustments! Not sure of which of the following it more appropriate. Just make sure you mark the original positions of the pots --- sam. (From: Mike Walker (vdospec@werewolf.net).) Caution: for the following, I would avoid touching the pot on the pickup itself unless you have exhausted all other possibilities - this is laser power and can easily result in a ruined laser --- sam. Sony will not give out any procedure, we have done it before many times... As far as the beam, the adjustment is on the CD sled itself right by the eye. The gain is located on the main board listed as gain, don't mess with the bias adjustment, try moving the gain about 1/8 inch or less clockwise, then check the play of your CD's, most of the time this takes care of the problem, if not try moving the beam focus about the same and same direction. Not to much on either it's been known you can burn out the laser. We like to mark our original postion with a red marker pen, you can lose where you were and really goof it up. Use ESD precautions, the laser is sentitive to static also. Also, try and replace the grease on the gear drive also, we have found that this helps a great deal also. Remove old, use new lubriplate or similar. (From: Jerry Jessop (jjessop1@home.com).) You have it backwards, adjust the Bias and leave the gain alone. If you set the bias level on wiper of the Pot to around 1.60 vdc with a CD loading that is "generally" a good figure. Now adjust the gain during an FMV sequence until it stops reading at one extreme. Then the other, and set it in the middle. Regrease the rails using "LaBelle 106" a white grease with teflon designed for plastic components found in hobby stores. Of course more than likely the optical sled has groves worn in it and now the laser azimuth is out of alignment. The only solution is to replace the entire pickup assembly. MCM claims to be getting a new shipment of Playstation optical pickups soon - their price is $39.95 (as of November, 1997). (From: Cyberchaos (cyberchaos@aol.com).) All earlier productions of the playstation utilized a plastic sled rail construction which collapses and causes this problem. These must be replaced with the upgraded steel versions. Cleaning is a very short term cure.

     

    Testing of Optical Pickup Assemblies

    Introduction

    Identifying front-end problems in CD players, CDROM drives, laserdisc players, and other optical drives is often thought to be a mysterious and difficult task. This section describes basic techniques confirming functionality of the laser diode, focus voice coil actuator, tracking voice coil actuator, and photodiode array. No exotic test equipment is required.
    It is strongly recommended that you read and become familiar with the other information in this document. For general optical pickup information, see the section: CD optical pickup operating principles. For a description of some common types, see the section: Sony KSS series optical pickups. Don't immediately conclude that your problem is in the optical pickup. It is likely elsewhere and you will not need to undertake the testing described below. If the unit is able to read the disc directory, if even erratically, then these tests are unnecessary (unless you suspect an intermittent in one of these subsystems) as all of major parts of the laser pickup assembly must be properly functioning in order to do this. However, this does not guarantee that there are not some marginal components such as a weak laser diode or shorted turns in the focus or tracking coil - more on these problems later. Don't ignore the trivial: have you cleaned the lens? Sometimes a dirty lens will result in symptoms that may be mistaken for much more serious problems. For intermittents, first carefully inspect the pickup assembly for bad solder connections and hairline cracks in the flexible printed cables. Interlock switches may be dirty or worn. Mechanical problems may result in intermittent behavior as well.

    When and why to test the pickup

    If you have examined the 'RF Test Point' with a scope and found a proper 'eye pattern', then as noted, these tests are not needed as this indicates proper functioning of all the major components of the optical pickup. If, however, any of the following are observed, then testing of the laser diode, focus and tracking actuators, and/or photodiode array is suggested:
    • The startup sequence does not complete due to obvious failure of the pickup to perform some action. For example, there is no attempt to focus.
    • Focus appears to be established but the directory is never displayed even though the disc spins at the correct speed - or overspeeds or does not spin in correct direction (clockwise as viewed from the label side is correct for CDs).
    • The 'eye pattern' is weak, distorted, or missing at the RF test point.
    Try to eliminate alternative causes before undertaking these tests as there is a slight chance of damage due to accidents or electrostatic discharge. Will it be worth the time and effort? Only you can decide how much your time is worth. There is a good chance that these tests will only confirm that the pickup is dead - not many of the faults you will be able to locate have easy fixes. You will learn something if that matters. However, with the cost of new single disc CD players less than $70 and changers less than $100, any rational analysis of the expected value for this undertaking may recommend the dumpster. But, we all know that hobbiest's time is not worth much - as in free. The descriptions below assume that the pickup is still installed in the player but selected portions are disconnected when required. This enables us to conveniently use the circuitry of the player to control certain functions for the 'live' laser diode and photodiode tests. It is also possible to test the pickup stand-alone but this will require an alternative power supply to drive the laser diode. Since the microcontroller will not be imposing its own will on those parts of the pickup still connected to the player, this may be preferable. However, if you are uncomfortable in providing a substitute power supply for the laser diode, then leave that function to the player. Caution: whenever applying external power to any component, totally disconnect it (by unpluging or unsoldering - label each wire if there is any ambiguity) to prevent damage to the circuitry on the logic board.

    Required tools, documentation, and test equipment

    Only a minimum of tools and test equipment are required for these testing techniques to be effective. An oscilloscope is desirable but a VOM or DMM can substitute in a pinch since no high frequency measurements are needed. However, we will assume a scope is available. This section does not address mechanical problems in the sled drive, or the drawer or spindle motors. These problems are adequately handled in the elsewhere in this document. It is assumed that these components have been verified to be functional as there correct operation may be required for some of the tests described below.
    A schematic will help greatly if available. Depending on the design of the unit, you may be able to infer enough about the front-end electronics to get away without one. The design of the components of the optical pickup are sufficiently similar among manufacturers to make the tests relatively model independent. What may differ are polarities of photodiodes, laser diodes, connector pinouts, etc. These can usually be determined fairly easily. Despite the incredible precision of the focus and tracking servos, we can perform meaningful tests without sophisticated or specialized test equipment. Also see the sections: "Troubleshooting tips" and "Test equipment". The following tools and test equipment will be required:
    1. Basic hand tools including precision jeweler's screwdrivers.
    2. A VOM or DMM.
    3. An oscilloscope (for photodiode/RF tests). For most of the tests, almost any scope will do as long as it has a DC coupled vertical amp. As noted above, a scope is not essential but is highly desirable.
    4. A 0 to 5 volt variable DC power supply (400 mA). The power supply can be a 4-5 V 'wall wart' with a Variac. Alternatively (but not as desirable), you can use a fixed 5 V supply with a series adjustable resistor (100 ohms for focus and tracking actuator testing, 250 ohms for laser diode testing). A highly regulated supply is not needed.
    5. Resistors: 22 ohm 1W, 5 ohm 1W, 50 ohm, 1 M ohm.
    6. Assorted test clip leads, a few feet of #24 solid hookup wire (RS232 quad or multiconductor phone cable is good source).
    7. IR detector circuit, IR detector card, or IR sensitive camcorder (for laser diode tests).
    8. (Optional) Slow speed sweep or function generator (1-10 Hz) with low impedance output or amplifier, see text.
    For the following discussions, a component CD player is assumed to be the unit under test. Make appropriate adjustments in interpretation if it is a portable CD player, CDROM drive, or optical drive.

    Precautions

    Reread the section: SAFETY for your own protection.
    To minimize the chances of damage to the laser diode - which is extremely sensitive to static and excess current - leave its connector plugged into the main board as much as possible and do not attempt to test the laser diode with a VOM (which on the low ohms scale may exceed the current rating of the laser diode - poof, even if only for a microsecond. As with all modern solid state equipment, preventing electrostatic discharges to sensitive components is critical. An antistatic wrist strap is desirable. In any case, work in an area where static is minimized - not on a carpet prone to static. Make it a habit to touch the metal chassis first to discharge yourself.

    Basic description of optical pickup

    Also see the more detailed description (including a diagram) of the typical optical pickup components and operation found in the section: CD optical pickup operating principles.
    In order for information or music to be read off of a CD, several systems must work closely together:
    1. Laser must be emitting a coherent beam of sufficient power and stability. Optical system must be clean and properly aligned. Laser power is maintained constant via an optical feedback loop controlling laser diode current. Therefore, a weak laser may not be salvageable as the feedback loop may have done all that is possible.
    2. Photodiode sensors must be functioning correctly for data recovery and focus and tracking feedback. In a 'three-beam pickup', there are six segments: the central segments A-D are used for focus and data recovery; the outer segments E and F are used for tracking feedback. In a 'single-beam pickup' segments E and F are omitted.
    3. Lens must be focused to within a fraction of a um of optimal to produce a diffraction limited spot. This is less than 2 um in diameter at the disc 'pits'. The lens is actually positioned several mm from the disc surface and is maintained at the correct distance through optical feedback controlling the lens position using the focus coil. Note: um = micrometer = 10E-6 meter; mm = millimeter = 10E-3 meter. 1 meter is 39.37 inches.
    4. Lens must align to within a fraction of a um of the center of the track. Tracks on a CD are spaced 1.6 um apart. Tracking is maintained via optical feedback controlling the radial lens position using the tracking coil (or radial positioning unit on some rotary positioners).
    Note that if the behavior while the CD player is attempting to read the directory changes whether a disc is in place or not, (and there is no separate disc sensor), then some or all of these components are functioning correctly. For example, many CD players will not attempt to rotate the spindle until proper focus has been established. Thus, if the CD rotates when in place but the bare spindle does not, it is likely - though not guaranteed - that focus is being established successfully.

    Identifying connections to the optical pickup

    In order to perform many of the tests described below, you will have to locate the drive and/or signal connections to the optical pickup. While there are many variations on the construction of optical pickups even from the same manufacturer, they all need to perform the same functions so the internal components are usually quite similar.
    Here is the connection diagram for a typical Sony pickup:
                                                      _
                  R1                  +---|<|----o A   |             +----o F+
               +-/\/\---o VR          |      PDA       |            (  
          PD1  |   |                  +---|<|----o B   |            (    Focus
      +---|<|--+---+----o PD (sense)  |      PDB        > Focus/    (    coil
      |                               +---|<|----o C   |  data      (
      |   LD1                         |      PDC       |             +----o F-
      +---|<|--+--------o LD (drive)  +---|<|----o D  _|
      |       _|_                     |      PDD      _              +----o T+
      |       --- C1                  +---|<|----o E   |            (
      |        |                      |      PDE        > Tracking  (  Tracking
      +--------+--------o G (common)  +---|<|----o F  _|            (    coil
                                      |      PDF                    (
       Laser diode assembly           |                              +----o T-
                                      +----------o K (Bias+)
       (includes LD/PD and                                        Focus/tracking
        flex cable with C, R).       Photodiode chip                 actuators
    
    
    The laser diode assembly and photodiode chip connections are typically all on a single flex cable with 10 to 12 conductors. The actuator connections may also be included or on a separate 4 conductor flex cable. The signals may be identified on the circuit board to which they attach with designations similar to those shown above. The signals A,C and B,D are usually shorted together near the connector as they are always used in pairs. The laser current test point, if present, will be near the connections for the laser diode assembly. It is usually possible to identify most of these connections with a strong light and magnifying glass - an patience - by tracing back from the components on the optical block. The locations of the laser diode assembly and photodiode array chip are usually easily identified. Some regulation and/or protection components may also be present. Note: There are often a pair of solder pads on two adjacent traces. These can be shorted with a glob of solder (use a grounded soldering iron!) which will protect the laser diode from ESD or other damage during handling and testing. This added precaution probably isn't needed but will not hurt. If these pads are shorted, then there is little risk of damaging the laser diode and a multimeter (but do not use a VOM on the X1 ohms range if it has one) can be safely used to identify component connections and polarity.

    Testing the laser diode while in the player

    Without a laser power meter, it will be difficult to fully verify laser functionality. However, determining that IR is emitted will provide a reasonable assurance of laser operation.
    For this test you will need an IR detector. A simple circuit is described in the section: IR detector circuit. This unit is also useful for testing of remote controls and other IR emitters. You can also use an IR detector card - available at an electronics distributor. In a pinch, CCD based camcorders are often sensitive to IR. It will appear as a bright spot if the laser beam is projected onto a white paper screen. However, you will probably need 3 or 4 arms to position the screen, push the play button, and hold the camcorder while attempting to view the detected spot through the viewfinder! You will need to gain access to the lens. This may require the removal of the clamper assembly. Once this is accomplished prepare to position the photodiode of the IR tester within 1/8" of the lens. Plug the unit in and turn it on. On portables, you will need to defeat the door interlock - use a toothpick or bit of cardboard. Sometimes a CD player will have a disc detect sensor separate from the laser assembly - this will need to be defeated in order for this test to work without a CD in place. If it is a simple optical sensor, a piece of black tape or paper should suffice. The first thing that should happen once a CD is in place and the play button is pressed is for the laser to be powered. You should be able to detect this in a darkened room because there is usually a very faint red appearing emission which you can see as a tiny red dot of light if you look at the lens from a safe distance of at least 6 inches at an oblique angle (WARNING: Do not look directly into the lens from directly above or from very close as the invisible IR is much stronger than the faint red emission and potentially hazardous). For a photo of how it actually looks in the dark, see Appearance of IR (780 nm) Laser in CD Pickup. (Original photos courtesy of Gag Helfront (ie.dunster@ukonline.co.u).) If you see the faint red light, you know that at least power is being applied to the laser diode. With the laser lit, the lens should go through a few focus search cycles - between 2 and 8 typically. While it is doing this, position the IR detector above the lens. If the laser is working, you will get a positive indication of IR in about a 30 degree cone on either side of the lens. While you have no way of knowing if the power output is correct, this is a reasonable indication of laser operation. Due to the wide angle of the beam, the power decreases rapidly with distance so you will need to be very close to the lens for a positive result. Note that if the lens moves smoothly in at least one direction (up or down), you have also confirmed that the focus actuator is functional. If the IR detector does not pick up a beam and you do not see the red dot, then either the laser diode is really dead or there is no power being applied by the control circuits. At this point, you have four options:
    1. You can give up. However, you would not have gotten this far if you were likely to be defeated so easily.
    2. You can attempt to obtain a schematic if you do not already have one so that you will be able to test the control circuits to determine if the laser diode is being powered.
    3. You can attempt to trace the laser power circuits in the hope that you will find something absolutely obvious that is amiss - a bad connection or open resistor, for example, resulting in no power to the laser diode. See the section: Electrical testing to see if laser diode is being powered.
    4. You can perform some simple but risky tests on the laser diode itself in an attempt to light it from an external power supply. As noted below, laser diodes are easily destroyed and you will have no warning. One nanosecond it will be a laser - the next it might be a DED - Dark Emitting Diode. See the section: Testing the laser diode with an external power supply.

    Electrical testing to see if laser diode is being powered

    Where there is absolutely no indication of an IR emission or that tiny red dot of light, but the lens is moving up and down attempting to focus, the next step is to determine if the laser diode is being powered - or is totally dead.
    • If you have a service manual, follow the instructions in there for checking the laser diode - usually a place to check laser diode current by measuring a voltage drop across a sense resistor or other testpoint.
      • If the reading is very low or 0, there is likely a fault in the driver or optical feedback circuitry.
      • If the reading is very high, the laser diode is likely bad and the driver is unable to compensate for low or no emission.

    • Without a service manual, look for a testpoint labeled 'laser power'. Even if you don't know what a correct reading should be, anything other than 0 would be a good indication that the driver is being enabled.
    • Where you have no service info, it may be possible to *carefully* measure across the laser diode with a multimeter to determine if there is any voltage there when it is supposed to be active. A normal reading would be 2 to 3 V.
      • For Sony and other similar pickups, there is a chip capacitor across the laser diode. The trick is in being able to attach meter probes to these points without destroying everything!
      • The flex cable may also have a pair of solder pads. It should be possible to attach fine wires to these for your multimeter. But, you must use a fine point - preferably grounded and temperature controlled - soldering iron to prevent damage.
      WARNING: Improper testing of the laser diode can damage it but a DMM with ESD precautions can probably be used. Make all connections with power OFF as the momentary glitch from attaching the probes and/or an accidental short circuit can easily toast the laser diode and other parts.

    Testing the laser diode with an external power supply

    Consider the following only if there is no indication of laser output while connected to the player and you do not have schematics or a service manual to determine if the laser power circuits are functional.
    Typical currents are in the 30-100 mA range at 1.7-2.5 V. However, the power curve is extremely non-linear. There is a lasing threshold below which there will be no output. For a diode rated at a threshold of 30 mA, the maximum operating current may be as low as 40 mA. A sensing photodiode is built into the same case as the laser diode to regulate beam power. It is critical to the life of the laser diode that under no circumstances is the safe current exceeded even for a microsecond! Laser diodes are also extremely sensitive to electrostatic discharge, so use appropriate precautions. Also, do not try to test them with a VOM which could on the low ohms scale exceed their safe current rating. Even connecting the test leads can blow the laser diode from static on a bad day. In addition, always make or break power or test connections with the player turned off. Locate the laser power connector by tracing back from the three pins on the laser diode assembly. Note: the following only applies if the laser diode is directly connected to the cable. If the power regulating circuit is on the pickup, you will need to trace its circuit or obtain the schematic as there are now too many variations to recommend a specific procedure. Use the 0 to 5 VDC linear supply (a switching supply may put out laser diode destroying pulses) with a 50 ohm resistor in series with the diode. This is preferred over the variable resistor power supply as there is less likelihood of any potentially laser destroying overshoot or noise. If you do use the variable resistor, make sure it is at its maximum resistance when you start and that this is sufficient to keep the current under 20 mA. Keep in mind that a wall wart rated at 5 V may actually put out 8 V or more when unloaded - check the current into a short circuit before connecting the laser diode. Slowly bring the current up until you get a beam. Use an IR detector for this! If you get the polarity backwards or are actually measuring across the internal photodiode, the voltage across the diode will go above 3 volts or will be less than 1 V. Then, turn power off and reverse the leads. Note: some laser diodes will be destroyed by reverse voltage greater than 3 V - a spec sheet will list the reverse voltage rating. The ones I have tried out of CD players were fine to at least 5 V in the reverse direction. Without a laser power meter, however, you will have no way of knowing when the limit on safe beam power (safe for the laser diode, that is) is reached. For this test, increase the current only until you get an indication on the IR detector or you see the red dot. You are not trying to measure power, just to see if it works at all. A typical threshold is around 30 mA. Sometimes, the operating current is marked on the pickup. If this is the case, do not exceed this current. If you detect a beam and there was none before, then your problem is most likely located in the player's control or power circuits, not in the pickup.

    Laser power adjustment

    If you have the service manual and it provides a procedure not requiring a laser power meter (which you probably do not have), then by all means follow that procedure.
    As noted elsewhere, it is possible to destroy the laser diode by attempting to adjust its output power. However, if you suspect a weak laser as indicated by noisy playback or poor tracking performance (not a dead one as this will not help), and have exhausted all other possibilities such as the servo adjustments - and feel you have nothing to lose, you may attempt one of the procedures described below (with some risk) to determine if the laser diode is at fault. Note that what adjusting laser power is probably doing isn't compensating for a decrease in laser diode intensity, but rather a buildup of dust and other junk on the optics (possibly internal and inaccessible) which reduces the beam intensity at the CD and the return beam intensity even more. There is a subtle difference as the optical output of the laser diode itself is feedback controlled and shouldn't drift much and the result of an adjustment will be an increase in laser output power beyond its normal range - which may indeed shorten its life substantially. If the laser output power HAS actually decreased, there is probably nothing that can be done as the feedback circuit is maxed out and the adjustment will have little effect. Thus, make sure the optics are as clean as possible before you touch laser power! The following requires that you can play a disc - even if it has some problems with noise or tracking. This is best done with an oscilloscope. However, if you do not have one, you can still try the procedure. The risk is that without a visual indication of the signal amplitude, you will turn the control too far before you realize it and destroy the laser diode. Note that the power may increase by turning the pot *counterclockwise* rather than in the normal clockwise direction! So, if nothing happens, you may be turning the power down. But, at least, that won't hurt anything. :)
    • If you have an oscilloscope, put a probe on the RF test point. While the disc is playing, you should see the eye pattern. Mark the exact amplitude of the peaks. Also, note the 'playback quality' so you will recognize if it changes. Note: while the correct voltage for the eye pattern is not the same in all players, typical values are in the 1 to 2 V range. If you see a few hundred mV or less, there is likely a problem. Caution: a weak eye pattern can also be due to improper focus bias adjustment (check it) or an electronic problem. The laser power may be normal. It may be safer to turn the laser power adjustment with player power off to avoid the possibility of electrical noise causing current spikes. Your choice. Mark the exact position of the laser power adjustment so you can get back to it if there is no effect or it makes things worse. Turn the control the slightest amount clockwise. Caution: this control may be very sensistive - 'slightest' really does mean just a very small amount. Turn power back on and/or note the eye pattern amplitude. If the laser diode is not at the limit of its power and thus bad, you should see the amplitude change from what it was. If it has decreased, try the other direction. Note the playback quality. Has it changed any? If not, then laser power is probably not your problem. If the amplitude of the eye pattern is unchanged, you either are turning the wrong control or the laser is at its power limit - and probably near the end of its life. Try the same test in the counterclockwise direction if the amplitude decreased - not every designer knows left from right. If there is improvement, you can risk leaving the control at the new (most likely) higher power setting realizing that you may be shortening the ultimate life of the laser diode. Do not push your luck by continuing to turn up the power unless you have exhausted all other alternatives.
    • If you do not have an oscilloscope. you can still attempt the procedure above, using audio listening exclusively to determine if there is any change. It is just a little bit riskier. As noted, the laser power adjustment may be very sensitive you will have no direct way of knowing how much you have increased the setting.

    Testing the focus and tracking actuators

    If there is a question of whether the lens is focusing or tracking properly, perform the following. Again, if the unit is able to read the disc directory at all, then these tests are not needed. Note that if you have a CD player with a rotary positioner, there may be no separate tracking coil as coarse and fine tracking may be combined.
    Typical linkages between the lens/coil assembly and the body of the pickup are (1) a sliding shaft (focus) and rotation on the shaft (tracking) or (2) a hinged-hinge. With (1), the slide can get gummed up preventing reliable focus and tracking. With (2), one or both hinges can break - they are often made of thin flexible plastic. Repair is not really possible. First, identify the cable leading to the focus and tracking voice coil mechanism. This is usually a 4 conductor cable separate from the data and laser cable (at least at the pickup end). Disconnect it from the mainboard before testing. Using a DMM or VOM, you should be able to locate a pair of coils with very low resistance - a few ohms. One of these is focus coil and the other is the tracking coil. Construct one of the following test circuits:
    1. Your 4-5 V DC wall wart plugged into a Variac with its output connected to a 22 ohm 1W resistor in series with a pair of 2 foot #24 insulated wires.
    2. Your 5 V DC power supply connected in series with the 100 ohm variable resistor and 22 ohm 1W resistor with a pair of 2 foot #24 insulated wires.
    Gain access to the lens for visual inspection. This may mean ejecting a disc, opening the drawer, or in some cases, actually removing the clamper. In a portable or boombox, the lens will be readily accessible. Unplug the CD player from the wall or remove the batteries - you will not be using its internal power. Locate one pair of the two pairs of low resistance connections you identified above. With your power supply off or the Variac turned all the way down, connect the #24 leads to one of these pairs. Now, turn on the power and slowly adjust the Variac or reostat while watching the lens. If you are connected to the focus coil, you may see the lens moving up and down. If you are connected to tracking coil, you may see it moving from side to side. If there is no motion, turn off the power supply, reverse the polarity and try again. For a typical pickup, the 4-5 V power supply and minimum of 22 ohms should cause the lens to move through the entire range of motion up and down or side to side as appropriate. Once you have exercised the first coil, switch connections and repeat for the other. If the motion is jerky, the lens assembly may be dirty. Clean it carefully first with a bit of compressed air (not high pressure, a photographic air bulb is fine) and then with Q-tips and isopropyl alcohol. Do not lubricate. Repeat the tests after the cleaning. If both the tests are positive, you have confirmed operation of the focus and tracking actuators. If either you were unable to locate both pairs of coils or one or both actuators did not move, then you have located a problem. An open coil can be due to a cable problem or a break at the coil. If the break is right at the solder connections which are usually visible once the plastic protective shroud is popped off, then it may be possible to repair it. This will require a great deal of manual dexterity and patience - the wire is really really fine. It is still possible for there to be shorted turns in the fine coils or an intermittent that was not detected.
    • Shorted turns would reduce the frequency response of the servo, reduce the reliability of focus or tracking, and increase the needed servo driver power. A CD player that is overly sensitive to slight disc defects even after all the proper adjustments have been performed may conceivably be a result of this type of fault. An additional symptom may be an unusually hot servo driver IC. However, many of these ICs run hot normally so don't panic as the possibility of shorted turns is really quite remote.
    • An intermittent may only show up during dynamic operation or with certain particularly finicky CDs or other peculiar circumstances. The intermittent could be at the solder connections or the fine printed ribbon cable that connects the moving lens assembly to the remainder of the pickup.

    Testing the photodiode array

    The photodiode array in a optical pickup consists of an IC with typically 4 or 6 detector segments. Four segments may be used for the less common 'single-beam pickup' while 6 segments are used in the 'three-beam pickup'.
    These segments are usually designated A-F. A, B, C, and D are the main detector which is used for both focusing and data recovery. Segments E and F are used in a 'three-beam pickup' for fine tracking feedback. We will assume a three-beam pickup for the remainder of this discussion. All 6 photodiodes are connected to a common point which during operation has a DC bias voltage on it typically around 5 V. If they are connected common anode, it will be negative; if common cathode, it will be positive. The reason is that the photodiodes need to be reverse biased for normal operation. The outputs of the photodiodes feed several operational amplifiers which are set up to amplify the current from the photodiodes. The normal connections may be at virtual ground potential or they may feed into large value resistors. The connector to the photodiode array is usually separate and will typically have at least 8 wires - photodiodes A-F, ground, and bias voltage. You will need to identify the wiring. First locate the ground using the ohmmeter. Then locate the bias - it will probably go to a low value resistor and then to the supply. Another way to identify the bias wire is to turn on the player and measure each of the possibilities. The bias will be the highest or lowest and will be solid with no noise or ripple. It will probably be powered all the time. Now for the photodiode segments. Very often the connections or some of the connections are marked on the circuit board. For example, there may be several labeled test points designated A+C, B+D, E, and F. Since the A and C segments and B and D segments are usually shorted together on the circuit board, this provided all the info needed to identify the photodiode connections. It is not important to distinguish between A and C or B and D for the following tests though you will want to be able to separate them. With power off, there is essentially no light on the photodiode array. Unplug the photodiode connector from the main board. Using your ohmmeter, test each diode for opens and shorts as you would test any signal diode. There should be a junction drop in the forward direction and very high resistance in the reverse direction. If you are using a DMM with a diode test mode, the junction drop will typically measure 0.7-0.8 V. There may be a very slight difference between the readings for segments A to D and those for E and F. An initial test of photodiode response can be made using an external light source - a flashlight or other incandescent bulb or IR remote control shining into the lens from directly above. With the multimeter connected to reverse bias each diode segment, shine the light into the lens. The resistance reading should drop somewhat - possibly dramatically. Segments A to D should show reasonably similar sensitivities but these may differ from segments E and F (which should be similar to each other). Similarly, with with the photodiode connections restored to normal, you can use an oscilloscope to monitor the RF test point. A source of IR directed into the lens from above may result in a detectable change in the signal - but only when the photodiode array is properly biased. This may be all the time that the CD player is turned on or only when it is trying to focus or perform some other operation. With an IR remote, you should actually see the pulsed signal for each key-code. On a typical Sony CD player, I was able to get about a 0.1 V signal at the RF test point using a VCR remote control as an IR source. However, even on a functional pickup, due to the nature of the optics, these responses may be very weak or undetectable. Thus, failure of either of the above tests is not strong evidence of a bad photodiode array. Any unusual readings such as a significantly lower resistance for one of the diodes, a short or open of a particular diode, a short between diodes, or variations in sensitivities is an indication of a problem. While it is possible for there to be a cable or soldering defect, this is somewhat unlikely though bad solder connections or breaks in the flexible cables are not out of the question. A defect found in the photodiode array will usually mean that the laser pickup is not salvageable with reasonable effort. Even if you could locate a replacement photodiode array, aligning and soldering the (most common) surface mount package would be quite a challenge without the factory jigs. Assuming these tests do not turn up anything, the next step will verify that the photodiodes are picking up an optical signal and will evaluate the relative strengths of each segment using the laser diode, optical system, and disc combination. Note that for these tests to confirm proper operation, the optical alignment must also be correct. For the tests using the internal laser diode, we will need to setup one of the following. Method (2) is more straightforward but requires the optional signal generator for best results. In each case the objective is to cause the lens-disc distance to sweep through perfect focus without requiring that the focus servo loop be closed. This will then result in a signal that will include the point of maximum signal amplitude on a periodic basis. Alternative methods may be used to accomplish the same purpose. Both techniques require the adjustable power supply previously used to test the focus coil.
    1. Adjustable focus with continuously rotating spindle. For the spindle motor, you will need a 1.5 V battery or your power supply with a suitable series resistor to cause the spindle to turn at approximately 1-2 Hz (rps). Warning: disconnect the motor from the mainboard! The unavoidable wobble of any disc is essential in this case and will sweep the focus distance by more than enough to cover the entire focus range of interest.
    Note: this assumes that the spindle is driven by a conventional PM DC motor. If it is a brushless DC motor, then some of the control electronics may be external to the motor and you will not be able to just provide a DC voltage to get it to rotate. If this is the case, you must use method #2.
    1. Stationary spindle but sweeping focus. This is the better method but requires a signal generator for easiest use. You can do this by hand using a Variac or reostat (this is easier if you have three functioning hands). A better method is to use a 1-10 Hz sinusoid or triangle wave from a low frequency signal generator with a low impedance output or feeding an emitter follower or audio amplifier to boost the current. This signal is then fed into the coil along with the focus offset derived from your power supply.
    Note: it may be possible to dispense with these test setups and just use the normal focus search of the CD player to provide the sweep. However, since we will be interfering with the proper feedback by removing selected sensors, there is no telling what the microcontroller will do. Therefore, breaking the feedback loop as we are doing is preferred. If the CD player appears to make many attempts at focus, this may be worth a shot, however. You will also need a disc - preferably one you do not care much about as sometimes it will get scratched due to opening the drawer accidentally or something equally idiotic while the disc is still rotating. Locate a 1 M ohm resistor and securely fasten it to a ground near the photodiode connector. Put your scope probe on the other end with its ground clipped to the same ground point as the resistor. Bend the free lead of the resistor completely over so that it will be able to hold the end of a wire like a mini-clip lead. Make sure you remember or mark down exactly how the connector is wired so that as you remove individual wires, you will be able to get them back in the proper spot. Presumably, you have already made a diagram of the photodiode connector wiring. Component players often have connectors with individually removable socket pins. A fine jeweler's screwdriver or paper clip may prove handy in removing these one at a time. Turn on your power supply and adjust the focus to about midrange. Start the spindle rotating or turn on the signal generator to provide a small sweep - about 1/10 V p-p as measured on the coil should be fine.

    Making the photodiode measurements

    Remove the wire corresponding to the photodiode (say, A) to be tested from the connector but leave the connector itself plugged into the main board. Set the scope for 1 V/div. vertical on a slow free running sweep.
    Clip the A wire into the resistor. Now, turn on power to the CD player. While the player thinks it is focusing, slowly adjust the focus voltage while observing the scope. As you approach proper focus, you will see the signal increase (depending on polarity) greatly, pass through a maximum, and then decrease. Depending on the design of the CD player, you may need to turn it off and on several times before you locate the signal as the microcontroller may give up pretty quickly with no focus or tracking coil servos (since you disconnected the actuators). If you have the service manual it may tell you how to force the laser to be powered all the time. Leave the focus set near the middle of the region of high signal. If you are using the signal generator to perform the focus sweep, you may need to optimize the amplitude of the signal by adjusting the signal generator output and offset from your power supply. You probably should not need to touch the settings for the remaining photodiode segment tests. Repeat the above procedure for each of the photodiodes A-F. All should produce fairly similar signals, say within 20 % of one another in amplitude. If A,B,C,D or E,F differ from one another by more than say, 20 %, there may be a serious optical alignment problem in the pickup (the player may have been dropped or bounced around without securing the hold-down screws, if any). Alternatively, the photodiode array may be bad. It is also possible for there to be partially shorted photodiode segments in which case, the outputs will not be independent as they should be. Loading one segment's output with a resistor may affect the output of one or more other segments. In any of these situations, such a discrepancy in A-D will prevent the establishment of proper stable lens position at the optimal focal distance. This will prevent the formation of a proper 'eye pattern' and subsequent data recovery. A significant difference between E and F (beyond the adjustment range of the tracking or E-F balance control) will prevent proper tracking. Note, however, that the signal amplitude from A-D and E,F may differ as A-D operate off of the main beam and E,F operate off of the first order diffracted beams which are weaker. As with the basic photodiode tests above, a failure here usually will require the replacement of the entire optical assembly. As noted, if the pickup's optical alignment is way off, there could be significant differences in photodiode responses. On component type units, it is unlikely that the optical alignment would shift on its own. Portables that have been dropped or automotive units subject to constant bumps and vibration could have alignment problems, however. If this is your last hope, then some experimentation with adjustment of the optical alignment on a successive approximation basis might be worth the effort. Mark the original position of any adjustments and try small variations on either side to determine their effect. You might get lucky. If this eventually results in improved uniformity of photodiode response, alignment may be the problem. If you can more or less equalize the response, reconnect the servos and attempt to get an eye pattern. If you can, optimize the eye pattern stability and amplitude using the optical alignment adjustments and servo adjustments.

    Sony KSS series optical pickups

    Note: For general information on optical pickups see the section: CD optical pickup operating principles.
    These are probably the most common optical pickups in the universe. Many variations - many dozens if not hundreds - on the basic design have been produced from before 1988 until the present. In general, they are compact, simple, robust (despite what you may have heard), and no doubt dirt cheap to manufacture. Depending on the type of player and mechanical constraints, the specific optical arrangement and construction will differ. Many brands of CD players and CDROM drives actually use Sony pickups. While these are all recognizable for their octagonal black lens cover and parallelogram type lens suspension for focus and tracking (neither of which has changed noticeably in 10 years), the construction of the fixed optics has gone through quite an evolutionary process:
    • Early KSS pickups were quite complex with most of the components described in the section: CD optical pickup operating principles mounted as separate components. These had accessible optical alignment adjustments and were also quite large and bulky compared to today's pickups. An example of one of these is the Sony KSS110C Optical Pickup.
    • Most of the KSS pickups found in consumer CD players and older CDROM drives combine some optical elements and eliminate others. For example, types like the very common KSS361A do not have a separate collimating lens or cylindrical lens. All parts are totally glued at the factory so no possible optical alignment adjustments are possible. A diagram showing the organization of the Sony KSS361A optical pickup is available in PDF format: CDKSSP.
    • The newest KSS series pickups appear to have combined the laser diode and photodiode into a single package. They are offset by a very small distance so the outgoing and return beams pass through the same optics and thus there is no longer a beam splitter - more cost reductions! By eliminating the optical components for redirecting the two beams, performance should also be better since this operation was not 100 percent efficient and additional optical surfaces can only degrade the beam quality. The small reduction in the clarity of the detected analog signal resulting from the very slight non-perpendicular (with respect to the disc 'pits' surface) beams should be more than made up for by these simplifications. While I do not yet have a sample of a Sony pickup of this design, the CMKS-81X Optical Pickup and Optical Pickup from Philips PCA80SC CDROM combine the laser diode and photodiode array into single package and eliminate all of the other optical components except the diffraction grating and turning mirror. I expect that Sony versions are similar.
    The description below is for pickups similar to the KSS361A and KSS210A. These are horizontally organized and less than 1/2 inch thick. The laser diode, grating, and beam splitter are mounted inside the casting of the optical block. The turning mirror is glued to its base plate, the photodiode array is glued to a port on its side and the objective lens and its focus and tracking actuators are mounted on a self contained removable unit. Please refer to the closeup views of the Sony KSS361A Optical Pickup. The following can be seen from the underside after removing a cover plate (1 screw). The descriptions are for the outgoing beam which originates at the laser diode, passes through the diffraction grating, then reflects from the dichroic beam splitter mirror on its way to the objective lens:
    • Laser diode. This is clamped and glued in place in a nicely finished brass barrel which is itself clamped and glued in place in the optical block. An adjustment for optical power sensitivity, is mounted on the flex cable next to the laser diode. This may mean that identical model pickups should be interchangeable without laser power adjustments - hopefully. Many players don't have a laser power adjustment pot on the electronics board. The front face of the laser diode package is angled so that the exit window (anti-reflection coated) is also mounted at what may be the Brewster angle, probably to further prevent stray reflections from the window's surfaces from feeding back into the laser diode's cavity or interfering with the detected signal. (At the Brewster angle, light polarized parallel to the window is totally reflected and light polarized perpendicular to it is totally transmitted. The output of these edge emitting laser diodes is polarized.) The Closeup of Laser Diode from Sony KSS361A Optical Pickup shows the angled front face and optical window. The reason it appears so HUGE is that the photo was scanned at 600 dpi - this is not a monster laser diode! It can be seen more like 'actual size' in the upper left corner of the group photo, A Variety of Small Laser Diodes.
    • Diffraction grating. Glued onto the end of the barrel in which the laser diode is mounted. The grating is at a 45 degree angle to produce the 3 spots for tracking in the appropriate orientation. (Once reflected through the lens the spots are in the direction tangential to the tracks).
    • Collimating lens. On some versions, there is an actual collimating lens. However, the most common models do not appear to have one. There is nothing really wrong with such a design, it is just unexpected. Their optical efficiency will be lower since some of the beam will be lost to the side walls but other than that, a shorter focal length objective lens should be able to compensate fully for a non-parallel beam. The optical path is so compact in these pickups that the losses are likely to be small. It is also not clear why otherwise very similar model pickups in very similar model CD players differ in this respect. A test of the laser diode barrel assembly removed from a KSS361A pickup shows that its output is an ellipsoidal beam with a divergence of at least 10 degrees on the narrow axis (across the grating) and somewhat greater than this in the orthogonal direction. These angles are consistent with a raw laser diode. If there were a collimating lens, the beam should be much less divergent. (My curiosity finally got the better of me and I ripped the laser diode from the barrel to confirm that there was indeed no collimating lens hiding inside!)
    • Polarizing dichroic beam splitter mirror. This thick mirror is mounted at a 45 degree angle and glued in place. The outgoing beam is reflected by the mirror toward the turning mirror and/or objective lens. The thick mirror also introduces astigmatism into the beam and this is how focusing servo feedback is accomplished. See the section: What happened to the cylindrical lens?.
    The outgoing beam reflects off of the turning mirror and then passes through the objective lens:
    • Turning mirror (models with horizontally oriented optics only). This is implemented as a coated glass front surface mirror glued to a 45 degree angled support which is in turn glued to the casting. The coating is mostly transparent to visible wavelengths of light - it is not aluminized.
    • Lens assembly. This appears to be very similar for all models. Of course, there are probably variations in focal length and other optical properties which cannot be determined by inspection.
      • Objective lens uses a double convex plastic molded design glued into a plastic frame which mounts the focus and tracking coils and is attached to the lens' suspension. Both surfaces are coated and the top surface, at least, is aspheric. A raised guard ring protects the optical surface from damage should the lens come in contact with the spinning disc.
      • Focus actuator is a pair of rectangular formed coils surrounding a pair of vertical magnet pole pieces.
      • Focus suspension is a parallelogram molded plastic design. This assures that the lens remains parallel to the disc as it moves up and down. The four hinges appear to be just very thin portions of the molded 4 sided box structure. These hinges are susceptible to weakening or failure.
      • Tracking actuator is a set of 4 circular coils glued to the outside surfaces of the focus coils and moving with respect to the same magnetic fields.
      • Tracking suspension is a single vertical molded hinge of similar design to that of focus. A second vertical hinge is also present but is restricted from free movement by a resilient rubber material. This appears to protect against sideways shocks. These hinges are susceptible to failure.
      • The magnets appear to be of a rare-earth type - very strong for their size.
      • A short flex cable links the terminals of the coils to 4 solder pads where the flex cable would normally connect from the electronics board.
      • Optical alignment is achieved with a 3-point mounting arrangement for the lens assembly. One of 3 screws with a spring clamps the frame. The two other screws are used for adjustment. The entire affair is aligned and then glued in place at the factory so adjustment in the field is virtually impossible - and unneeded in any case.
      • The lens assembly can be removed by unsoldering the 4 solder pad flex cable and unscrewing two very small Torx type screws from the top (these will succumb to a roughly 0.7 mm hex wrench. It then lifts off. Optical alignment should not disturbed. Note: Just loosening the Torx screws permits lens assembly to be shifted slightly though some small amount of adhesive may need to be removed to free it. This should have an effect on optical alignment. I will do some experiments at some point to determine its precise effect.
    After passing back through the objective lens and reflecting off of the turning mirror, the return beam passes through the dichroic beam splitter mirror and hits the photodiode array.
    • Photodetector array. Glued to a plate with the 8 pins (7 connected) poking out the back and soldered to the flex cable. Approximate dimensions of actual sensor area shown.
                       |<---------- 0.6 mm ----------->|
             
                  ---- +-------------------------------+
                   ^   |       |       |       |       |
                   |   |       |       |       |       |
                   |   |       |   A   |   B   |       |
                   |   |       |       |       |       |
                   |   |       |       |       |       |
                0.3 mm |   E   |-------+-------|   F   |
                   |   |       |       |       |       |
                   |   |       |       |       |       |
                   |   |       |   C   |   D   |       |
                   |   |       |       |       |       |
                   v   |       |       |       |       |
                  ---- +-------------------------------+
      
      
      These are the 6 segment silicon photodiodes (for a three-beam pickup. (For a single-beam pickup, there will be 4 but as far as I know, all Sony pickups are all 3 beam types). Note that the entire active area is a fraction of a mm in each dimension. This emphasizes the likely critical nature of optical alignment. Nonetheless, with everything screwed and/or glued in place, the likelihood of this ever changing is small.
    • Flexible cables. In most cases, there are two - a 12 or so conductor cable for the laser power and photodiode return signals and a 4 conductor cable for the focus and tracking actuator drive. However, there are many many variations on the specific layout. These are either soldered to the electronics board or more commonly, terminate in clamp-type connectors.

    What happened to the cylindrical lens?

    It would appear that the mystery is solved:

    Fabulous! That has to be it. I even just did an experiment with a 1.5 inch think piece of Plexiglas and a lens - the astigmatism was clearly visible and it isn't a subtle effect. The astigmatism of the laser diode may contribute but probably is small compared to the result of passing through the thick beam splitter. I should have wondered why Sony would use extra material if there weren't a good reason! :-)
    A possible explanation of my version is the position of ABCD diodes on its chip: they are always tailored to the mirror in different systems with different mirror position: compare SONY and SANYO, so that the A-C (or B-D) line is parallel to corresponding sides of the mirror, at the same time the axes of astigmatic spot of the inclined mirror are also parallel to the mentioned sides. Interesting, that the position of EF can be either on the A-C line or between A-C,B-D lines, that means that diffraction grating molded with laser unit can be so or other way turned in the whole system but I suspect that it is always tailored to wedge beam of laser, so the proposed astigmatism of laser is hardly used.

    Interchangeability of Sony KSS pickups

    If you have looked inside a variety of CD players, you probably have noticed (1) that many use Sony pickups (the characteristic octagonal black lens cover) and (2) that many of *these* appear similar even if their model numbers differ. A closer examination will reveal that many many different types use what would appear to be the identical optical block - the casting that mounts the lens and its actuators, the laser diode, and photodiode array. If you delve even deeper, you would find that the optical paths are identical as well. The only obvious difference in many cases are in the mounting and the way the sled is driven, and in the configuration of the flex cable and its connections. So, are the optical blocks themselves indeed interchangeable?
    The answer is a definite 'maybe' and servo adjustments may be needed in some cases (where none would possibly be necessary with an exact replacement). However, there could be cases where where differences are too great. I am not sure I believe the differences listed below since much of the pickup behavior in terms of bump immunity and drop-out performance is based in the servo loop electronics, not the pickup. So, while I do not know for sure, my guess is that the A and B versions would be totally interchangeable if the CD player electronics have enough adjustment range. (From: Lance Edmonds (lanceedmonds@xtra.co.nz).) Sony KSS150A is compatible with KSS210A and KSS212A. However, due to signal levels KSS210A and KSS210B have differing specs. The rule here is that a KSS210B can be used in place of a KSS210A, but for optimal performance, an A should not be used in place of a B.
    • B versions designed for "ghetto-blasters" (lower drop-out performance and higher vibration resistance).
    • A versions for desk-top models (higher drop-out performance, lower vibration resistance).
    Source of info: Sony Japan Designer who visited me a few years ago. Yes they actually send their technical staff around the world to get an idea of what happens to the products after sale! Not often, but it does happen. Over the years I've met designers, technical managers, technicians, and a load of marketing folks from Japan and Singapore.

    Super simple optical pickups (sort of)

    Some of the modern generation designs are about as simple as possible in terms of the number of separate components and still perform the needed functions of a single-beam or three-beam optical pickup. While the objective lens assembly with its focus and tracking actuators is of standard construction, there are few additional components. However, the term "simple" is really not accurate. The technology that enables the number of discrete components to be minimized is quite sophisticated.
    The CMKS-81X Optical Pickup and Optical Pickup from Philips PCA80SC CDROM are typical of such designs. Sony also manufactures such a pickup, apparently used in some revisions of its PlayStation PSX and elsewhere. The smallest ones such as the Optical Pickup from the Philips CR-206 CDROM are only about 1/2" x 5/8" x 3/4" overall - just about the size of the lens cover! The LD assembly has a Holographic Optical Element (HOE) glued to its front to among other things, divert the return beam to the PD array. Aside from that, the only other component not visible is a fixed collimating lens. A diagram showing the organization of the CR-206 is available in PDF format: CDSSBP. (Being revised.) The following is my current (limited) understanding of how this thing works:
    • The laser diode and photodiode array (LD/PDA) are combined into a single package about the diameter of a larger LD but extra tall with 10 pins - 3 for the LD and its monitor photodiode and 7 for the PDA.
    • A glass plate roughly 3 mm on a side and 1 mm thick is glued to the front of this LD/PDA package. In the center is a spot about 1 mm in diameter etched on the outer surface which is a Holographic Optical Element (HOE). This is directly over the emitting facet of the LD and separated from it by 5 to 7 mm, a fraction of a mm less from the PD array (the thickness of the PD chip). While there is a narrow clear region surrounding the HOE spot, it doesn't seem likely that this is actually used for beams in either direction. DVD Laser Holographic Optical Element shows closeup of an HOE, though it's not the same one as used in this pickup.
    • After removing the HOE and cutting off the top of the package, see Interior View of Combined LD/PDA Hologram Laser from Philips CR-206 CDROM. In the center is the LD chip oriented vertically. Beneath it is the monitor photodiode chip. To the right is the PD array chip with its 6 connections. Yes, this has seen better days as several of the bonding wires have been broken. :( :)
    • The raw LD beam passes through the HOE on its way out and is split into three parts. But this is NOT a three-beam pickup! In fact, the two 1st order beams spread at about a 20 degree angle - so fast that they do not make it through the objective lens at all. Only the 0th order undeflected beam makes it to the disc. Yet, the 1st order beams are equal in intensity - or perhaps even a bit stronger - than the 0th order beam. And that's all wasted. More on this below for the return path.
    • There is an aperture just beyond the HOE about the size of the HOE spot which further limits the angle of any outgoing beam(s) and may serve to help circularize the normally very asymmetric beam from the LD. (Add hand-waving here.)
    • The turning mirror is oriented at about 42 degrees from the horizontal, not 45 degrees as expected. The result is that the beam hitting the disc will be at 5 to 10 degrees from the normal. It is not possible to orient the beam going to the turning mirror to produce normal incidence at the disc.
    • A fixed collimating lens reduces the divergence of the raw LD beam before it gets to the objective lens. Its focal length is around 1 cm.
    • The objective lens uses a single axis voice coil positioner for focus. The voice coil is surrounded by a ring magnet and is on a flexure suspension. It is assumed to be similar to other CD objective lenses with a 4 mm focal length and NA of 0.45. However, unlike most others, it is a plano-asphere. CD objective lenses are typically double asphere or sphere.
    • The return beam passes back through the objective and collimating lenses and reflects off the turning mirror to hit the HOE.
    • The HOE splits the return beam into three parts - a 0th order undeflected beam and a pair of 1st order beams, again separated from the 0th order beam by about 20 degrees. One of the 1st order beams appears to have just the right offset to hit the PD array. The other 1st order beam and 0th order beam are not used. Thus, ignoring losses in the optical system and in the reflection from the CD surface, 90 percent or more of the laser power has been wasted! However, putting that into perspective, modern pickup typically use a simple (non-polarizing) beam-splitter which results in 75 percent of the laser power being wasted (50 percent each way). Only older pickups, or those where laser power is limited (like some for Blu-ray) use a polarizing beam-splitter and quarter waveplate, which would in theory be 100 percent efficient.
    • The deflection angle of the 1st order beam is altered by a few degrees depending on which half of the HOE it hits. Since the return beam has finite size, this means that there may be two sub-beams with the intensity of each one depending on the precise position of the return beam on the HOE.
    • The location(s) on the PD array where the return 1st order beams hit will be a very sensitive function of the returning beam's location. It is believed (though not confirmed) that the slightly off-axis beam orientation at the disc in conjunction with the split 1st order return beam is what's used by the feedback system to control tracking and/or focus. Although it's hard to see in Interior View of Combined LD/PDA Hologram Laser from Philips CR-206 CDROM, the PD array appears to have 4 parallel lines on it which could be 4 long photodiodes. Counting wire bonds counterclockwise starting at the lower left, they are 1, 2, 3, and 4, and may be for the 1st order sub-beams. There are also two other connections to the PD array, purpose unknown (as if the purpose of everything else is known!). Perhaps they are for additional photodiodes that aren't obvious, or buried connections to pairs of the other four.
    More to come including no doubt, additional extensive hand-waving. :) 

    Itmes of Interest

    CD technology basic specifications

         Parameter             Compact Disc/CD-R
     ----------------------------------------------------------------------------
    
       Full Disk diameter:     120 mm (4.75").
       Disk thickness:         1.2 mm.
       Disk material:          Polycarbonate.
       Track width:            0.6 micron (um) approx.
       Track pitch:            1.6 microns (nominal).
       Playing time (audio):   74 minutes, 15 seconds (>78 minutes by cheating)
       Data capacity (CDROM):  >650 MB
       Sampling frequency:     44.1 kHz per channel.
       Number of channels:     2.
       Sample size:            16 bit linear, two's complement code.
       Bit rate:               4.3218 M bits/second average (1X).
       Data rate (CDROM):      150-2400 KBytes/second (1X-16X).
       Spindle speed:          200 to 500 rpm (1X, constant linear velocity).
       Linear speed:           1.2 to 1.4 meter/second (1X).
       Modulation:             Eight-to-fourteen modulation, RLL(3,11).
       Error Correction:       Cross Interleave Reed-Solomon Code - CIRC.
       Laser type:             Semiconductor Diode GaAlAs.
       Laser wavelength:       780 nm (most common).
       Laser power:            0.1-1 mW. typical (at lens).
       Frequency response:     5 to 20,000 Hz +/- 3 dB.
       Harmonic distortion:    0.008 % at 1 kHz.
       Dynamic range:          Greater than 90 dB.
       Signal to noise ratio:  Greater than 85 dB.
       Wow and flutter:        Below measurable limit (as good as crystal).
    
    

    Comparison of CD, DVD, BD Specifications

    CD = Compact Disc/k, DVD = Digital Versatile Disc/k, BD = Blu-ray Disc/k.
         Parameter                     CD          DVD          BD
     -------------------------------------------------------------------------
       Disk diameter                120 mm       120 mm       120 mm
       Disk thickness               1.2 mm       1.2 mm       1.2 mm
       Disk structure               Single      Two bonded     ???
                                    substrate     0.6 mm      0.1 mm
                                                substrates   substrate
       Laser wavelength             780 nm       650 nm       405 nm
       Numerical aperture            0.45         0.60         0.85
       Track pitch                  1.6 um       0.74 um       0.32
       Minimum pit/land lgth       0.83 um       0.4 um      0.138 um
       1X speed (CLV)             1.2 m/sec     4.0 m/sec
       1X data rate (mode 1)      1.2 Mb/sec    11 Mb/sec    36 Mb/sec
                    (mode 2)                    
       Number of data layers         One                    One or two
       Number of sides               One                    One or two
    
       Data capacity              ~680 MB      4.7 GB (1L)    27 GB
                                               8.5 GB (2L)
                                              17 GB (2L/2S)
    
    The reduced track pitch and pit length made possible by the shorter wavelength and advances in optical readout technology accounts for the almost 8-fold increase in data storage capacity on a single layer. For more information on DVD and BD technology, check out the following sites:

    A down-to-earth comparison of digital and analog recording

    Digital solutions to anything are not inherently superior to old style analog approaches. Digital storage and playback can result in truly terrible sound if the underlying technology specifications and implementation are inadequate. However, for storage, there is a fundamental difference which can be expressed in simple terms:
    (From: Michael A. Covington (mcovingt@ai.uga.edu).) The way I explain digital recording to people is this:
    • Digital recording is like hiring somebody to type a paper for you, from a typed original. If they hit the same keys you did, there is no loss of fidelity at all. If they make an error, you can find it and correct it.
    • Analog recording is like hiring an artist to copy a painting. It is going to come out a little different no matter how good they are.

    What is oversampling?

    CD audio reads 16 bit samples off of the disc at a rate of 44.1 K samples per second (for each channel). This is the 1X rate. It is possible to produce *perfectly* faithful sound reproduction at 1X. However, digital sampling theory and the Nyquist criterion then require an analog filter which has a flat frequency response in the audio passband - 20 Hz to 20 kHz, and 0 at 22.05 kHz (1/2 the sampling rate) and above. The filter is necessary to remove 'aliasing' artifacts which would produce frequencies in the output not present in the original recording. Such filters are are possible but very difficult to design and tend to have nasty phase response as you get near 20 kHz since the filter response needs to go from 1 to 0 within a very small frequency range (20-22.05 kHz). The phase response may have an effect on stereo imaging and instrument localization. Whether you can hear any of this depends on whether you have 'golden ears' or not.
    Enter oversampling. Instead of putting out the original CD samples at 44.1 kHz, digitally interpolate intermediate samples so that the D/A converter can work at 2X, 4X, 8X or more. The digital filters can be designed with very good performance and are part of the VLSI chipset in the CD player. For example, with 4X oversampling, three interpolated samples will be inserted between each original 44.1 kHz sample and the D/A will run at 176.4 kHz. An analog antialiasing filter is still needed at the output but its response only needs to go from 1 to 0 over the range 20 kHz to 88.2 kHz - a much much easier filter to design. Which will sound better? There is a lot of hype. It may depend more on the quality of either design rather than the basic technique. So many other factors enter into the ultimate listening experience that the difference in in frequency and phase response around 20 kHz can easily be overshadowed by errors introduced throughout the recording process as well as playback considerations such as speaker quality and placement, room acoustics, and listener location. Most consumer grade CD players now use oversampling. The newest fad is the 1 bit D/A with 256X (or more) oversampling. This is largely cost driven as well: you don't even need a high quality 16 bit D/A anymore. The simplest way of describing this approach is that it is a combination of pulse width modulation and sophisticated interpolation. The net result is audibly the same as all the others.

    In fact, it *is* a 1-bit D/A converter...
    Rather than making an expensive 16-bit converter out of a carefully trimmed set of resistors, current sources, and other analog components, the manufacturers cost-improved the D-A converter by clocking out digital patterns at a rate much faster than the sampling rate. For example, a reading of 0 volts would be 101010101010, where -1 volt would be 00000000, and +1 volt would be 11111111. A string of 100100100 would be somewhere in the -.333 volt region. (these are just a normalized example). Because everything is defined by the designer (digitally), very few adjustments are necessary when the player is actually made. When analog components are used, they must be trimmed to make them accurate. This very fast digital stream is then run through a low-pass filter, which converts the very fast square wave into its 'average' value, which is supposed to be the original music signal. There is much debate as to what type of D-A sounds better. Personally, I like to stay away from 1-bit D/A converters, but the last time I listened to a 1-bit D/A is about two or three years ago. I thought they sounded a bit muddy. 

    What is an anti-aliasing filter

    Antialiasing filters are needed in a sampled data system (of which digital audio is one example) to guarantee that out-of-band signals do not confuse the digitization process or find their way into the output.
    1. Prior to sampling and digitizing, an antialiasing filter is used to cut off all frequencies above Fmax where Fmax is the highest frequency that it is desirable to reproduce. Sampling per Nyquist must be at least at 2*Fmax but making it somewhat higher than this enables the antialiasing filter to be more easily designed. For example, CDs reproduce 20 kHz as Fmax and sample at 44.1 Ks/sec. The antialiasing filter must have a response which is substantially flat to 20 kHz and then rolls off to 0 before 22.05 kHz. If this is not done, frequencies between 22.05 kHz and 44.1 kHz (as well as any above) will be reflected back in the digitized samples resulting in aliasing noise which is mighty peculiar sounding! Thus, the signal flow for input is:
        Mic or \|  +-----------+  +--------------+  +---------+  +-----+    Digital
        other   +->+   Audio   +->+ Antialiasing +->+ Sample/ +->+ A/D +--> proc.,
        source /|  | Amplifier |  |    Filter    |  |  Hold   |  +-----+    storage.
                   +-----------+  +--------------+  +---------+
      

    2. Following the D/A, an antialiasing filter with a similar roll off is used to remove all frequencies above Fmax introduced by the D/A process. Thus, the signal flow for output is:
                                                                  /
                    +-----+  +--------------+  +-----------+   |/
        Digital o-->+ D/A +->+ Antialiasing +->+   Audio   +-->+  Loudspeaker
        Sample      |     |  |    Filter    |  | Amplifier |   |\
                    +-----+  +--------------+  +-----------+      \
      
      
      The output antialiasing filter is not for antialiasing in the same sense as the input filter (before digitization) but without it, similar audible effects can take place in subsequent amplification stages which respond in a non-linear fashion to any high frequency (out of band) sample or clock noise that gets through.
    3. Oversampling techniques can be used on both input and output to simplify the filter design. Prior to the D/A, additional digital samples are interpolated between the original samples read off of the CD. Thus, the digital samples will typically already be at some multiple of 44.1 kHz. The D/A then runs at a much higher sample (clock) rate decreasing the demands on the analog filer. See the section: What is oversampling?.

    How good are the digital filters in digital audio systems?

    (From: Winfield Hill (hill@rowland.org).)
    The digital filters within a typical CD-sound sampling system are very good indeed. I'm looking at a few AES papers reprinted in the 1994 Crystal Semiconductor databook (so we're talking "old" technology!), and I see the amazing performance possible with the linear-phase finite-impulse-response (FIR) filters in the delta-sigma A/D chips. For example, the Crystal CS5328 has a flat response to 22.5kHz and then drops like the proverbial rock to a first -105dB dip at 26kHz. Ditto for the filters in a high-quality D/A like the CS4328. Also, the in-band frequency response is very good. Passband ripple within +0.00025 and -0.0004dB to 10kHz. Hmmm, deteriorating to -0.0006dB at 17.5kHz. And for the D/A chip, a flat line on the chart (I can't see under 0.01dB) to 20kHz with a slight 0.1 dB rise by 22kHz. Strike that "very good," insert PERFECT. The Crystal CS5328 A/D has a very low -105dB distortion with full-scale analog input, and -125dB with -10dB input. That works out to under 0.0005% at full scale and even less for typical signals. The CS4328 D/A is not quite as good, with under -92dB (0.0025%), but I'll not complain! Also, they and others (e.g. Analog Devices) make better parts for the purist.

    Instant oversampling theory

    (Mostly from: Lasse Langwadt Christensen (fuz@control.auc.dk).)
    When you have a signal from a CD sampled at 44.1 kHz, the resulting frequency spectrum looks something like this after the D/A converter:
     Amplitude
       |
       |
     __|_____       ___________
       |     \     /           \
       |      \   /             \
     --+--------+--------+-----------> Frequency
       0       Fs/2      Fs             Fs=44.1 kHz
    
    
    After the D/A converter you then need a antialiasing filter to remove the frequencies around the sampling frequency (Fs). That filter has to pass the frequencies you need 0-20 kHz and remove (-96dB) the frequencies above Fs/2 (22.05 kHz). Thats a pretty sharp filter - which is a problem, since it has to be an analog filter. This is where oversampling come in. If you insert one zero sample in between every real sample, you get a signal looking something like this: where X = originally sampled values, 0 = inserted zeroes Note: The analog signal would look like a line connecting the the X's, not ASCII friendly :-).
     Amplitude
       |
       |
       X         X     
       |         |         X         X
       |         |         |         |
     --+----0----+----0----+----0----+---> Time
       0        1/Fs      2/Fs      3/Fs    Fs=44.1 kHz
    
    
    The sampling frequency has now been increased to 88.2 Khz (2X oversampling) and in frequency it would look something like this:
     Amplitude
       |
       |
     __|_____       ___________     ____________
       |     \     /           \   /            \
       |      \   /             \ /              \
     --+--------+--------+----------------+-----------> Frequency
       0       Fs/2      Fs              Fs*2            Fs=44.1 kHz
                                                         new_Fs=88.2 kHz
    
    
    If you now filter that signal with a digital filter (before the D/A), with the same specifications as the previous analog antialising filter, (it is a lot easier doing it digital than analog, you get a signal something like this in frequency:
     Amplitude
       |
       |
     __|_____                         ___________
       |     \                       /           \
       |      \                     /             \
     --+--------+--------+--------+--------+-----------> Frequency
       0       Fs/2      Fs              Fs*2             Fs=44.1kHz
    
    
    And in time domain would look something like this:
     Amplitude
       |
       |
       X    I    X     
       |    |    |    I   
       |    |    |    |    X    I    X
       |    |    |    |    |    |    |
     --+----+----+----+----+----+----+---> Time
       0        1/Fs      2/Fs     3/Fs     Fs=44.1kHz
    
    
    As you can see from the signal in the frequency domain, the analog antialiasing does not need to be as sharp as before, it still has to pass the frequencies from 0-22.05 kHz but it only have to remove frequencies above 44.1kHz (the new Fs/2). This is much much easier. If you look at the signal, in time domain, you can see that the original samples (X) are still where they where, but the I`s has been moved, so they are placed as if the signal had really been sampled twice as fast. Since the extra samples are interpolated from the original samples, are they only limited in accuracy, by how many bits that was used in the filter. So the signal after the digital filter could in theory be any number of bits, and thats why a 18, 20, or 22 bit D/A-converter is sometimes used.

    Is there a difference between CDs for 1X, 2X, or 25X CDROM drives?

    A CD may be recorded at a 1X, 2X, 4X, etc. rate but what is on the CD is supposed to be the same.
    However, the location of the information on the disc may have been optimized for use readout at a 1X, 2X, 4X, etc. rate on a particular drive/computer combination but again what is on the CD is coded the same way and should be read properly regardless of the speed of the CDROM drive. However, actual performance including interactions with multimedia programs, and sound and video devices may be vary dramatically. For CDROMs, the 8X specification is not related to the 8X oversampling of an audio player. An 8X CDROM drive can actually spin at up to 8 times the normal speed of an audio CD. It can transfer data at 8 times the 1X (audio) speed of 150 KB/second or about 1.2 MB/second. However, note that the actual access time for an 8X CDROM drive may not be dramatically better than that of a 1X drive once the seek time is taken into consideration. A CDROM drive must get the data unaltered even with defects on the disc. An occasional unrecoverable error on an audio CD will never be detected. However, a dropped bit could render a program disc useless. Therefore, a CDROM disc is coded with additional levels of error correction and a CDROM drive has the required decoding logic to deal with this information. The interpolation used for oversampling and the interpolation and/or muting used for dealing with unrecoverable errors in audio players are not useful for data. How the CDROM drive actually deals with audio playback is a totally separate issue from its data readout performance. For example, an 8X CDROM may actually use 4X oversampling for its audio playback but nothing else. Conceivably, an 8X CD ROM could buffer and read ahead - and re-read a segment of the disc if errors are found (as some people think normal CD players do but generally do not - at least not in the context of oversampling). Sophisticated programs reading audio data off the CD could certainly do this on a greater than 1X drive. I do not know whether any CDROM drives themselves would do this given that audio performance is not something that is generally considered that important on a CDROM drive. An audio player using oversampling never need to spin the disc faster than the 1X speed but implement the interpolation to simplify the analog filter design. However, portable players with a 'bump immunity feature' have several seconds of audio sample memory and will read (prefetch) the audio information off of the disc at higher than 1X speed to assure that the buffer can be kept as full as possible even if the player is unable to track for a couple of seconds.

    CDROM drive speed - where will it end?

    CDROM drives advertised as 16X are now common. Taken literally, this would mean that at the inner track, this drive must spin the CD at 500*16 or 8,000 rpm. Geez, they must have a Kevlar shield around the perimeter to catch any shrapnel should the CD disintegrate! (Apparently, this isn't as rediculous as it sounds - see the description of an "event", below.) Have you ever seen the slow motion video of a jet engine exploding? Just about one year ago, I was 'proving' why such technology would never be practical. So much for predicting the future. Have I mentioned that my crystal ball has been in the shop for the last few years awaiting repair? :-)
    However, most 16X drives really are not 16X CDROM drives. Some drives do advertise '16X max' which might indicate a constant rotation apeed of a much more reasonable 3,200 rpm resulting in a transfer rate which approaches 16X only near the edge (outer tracks where 1X would be 200 rpm). The transfer rate could be as 'low' as 6.4X near the center. Another possibility is a hybrid approach called Partial Constant Angular Velocity (PCAV) with a more modest 8X speed (around a constant 4240 rpm) for the inner tracks topping off at 16X near (5/6ths of the way radially to) the outer edge (at which point the rotation speed decreases to limit the peak transfer rate to 16X). 12X drives typically run at a true 12X rate with the CLV varying between 6360 and 2400 rpm across the disc. These will actually have a faster transfer rate than '16X max' drives since most discs are not full and the most frequently accessed data is near the center - where the '16X max' drives are only really operating at 8X. One factor limiting the performance of present drives is the speed of the Digital Signal Processing (DSP) chipset which is used to perform the decoding and error handling (i.e., EFM and CIRC). This is one area where there will no doubt be rapid advances. There is nothing to prohibit a fully Constant Angular Velocity (CAV as opposed to CLV or PCAV) approach from being used as long as the DSP can keep up. This would mean that the transfer rate varies continuously across the disc. An added bonus would be that CAV would actually greatly reduce stress on the spindle motor and its servo system allowing for much lower cost components and improved reliability. There are other ways, at least in principle, of increasing the performance of CDROM drives without spinning the discs at hyperwarp speeds. These involve the use of multiple laser beams or entire laser pickups to read data from multiple tracks in parallel. However, the hardware and software for these schemes become extremely complex and expensive to implement due to the CLV encoding, CD tolerances, and other factors. Therefore, spinning the disc faster has become the solution of choice. In addition, the seek time of the CDROM drive will dominate for short file transfers. Since this specification is not as hyped as the 'X' rating, these are often pathetic - 200 to 300 ms full stroke being typical even for high-X (e.g., 16X) CDROM drives. Of course, ultimately, it is the speed of the computer interface, system bus, CPU, and software, which limits actual performance. Just because you have a high speed CDROM does not mean it will behave as expected on your system. There is some question as to whether discs manufactured to current tolerances can be spun much above 6,000 rpm without vibrating themselves to pieces. Other than this slight 'problem', there really isn't any fundamental reason why faster drives could not be built. Perhaps, discs will simply need to be approved for high perfomance drives (sort of like grinding wheels: "Do not exceed 8,500 rpm") - "Do not use above 40X". Therefore, a drive spun at a constant 8,000 rpm with an advanced DSP chipset could operate with '30X max' performance. Are you marketers listening? Now (August 1997) some company is offering a 24X CDROM drive! Stay tuned for "Safety precautions and recommended body armor when using or troubleshooting a 100X CDROM drive" :-). Here are a couple of data points on ultimate CD speed limits: For the following, if one assumes the worst case, 1X is equivalent to 500 rpm. You can do the heavy math. :-) (From: Richard Griffin (rjgriffin@viewlogic.com).) I just thought I would chip in with my 2 cents worth...... There have been studies into just how fast you can spin your average CD without structural problems occurring. I believe Philips (UK) conducted the study. They found that spinning a disc up to the equivalent of 45X caused the disc to stretch enough due to the centripetal forces to make it impossible for the laser to track the track (if you catch my drift). Just for the sheer hell of it, they wound the test discs up to 56X at which point they scattered themselves in a very artistic 'splinter' formation all over the test lab. (From: Scott May (scottmay4@home.com).) My wife was browsing a the contents of a CD-ROM on her computer when suddenly there was a loud noise, followed by shards of what was once her CD-ROM, now raining down on our heads. The door to the Memorex drive (model CD-482E) was blown off its hinges, and left dangling by a small spring. About the room were fragments of the CD, mostly in splinters, and few larger than dime. Inside the CD-ROM drive were the remains of the disc. I was able to open the door using the manual release, but could not open more than halfway. Internal drive parts were blasted off and mixed with CD rubble. We are both very lucky not to have suffered injuries, because of flying debris. But I'm dumb-founded as to the cause of this major malfunction. I've never heard of this happening to anyone before. And to be honest, I wouldn't believe it if it hadn't happened to me. The drive was about a year old, but we have no idea if the CD had any surface flaws or physical defects. (From: Sam.) There couldn't have been any major structural defects or it wouldn't have been usable. That's why I suggested Kevlar encased CDROM drives. With these high-X drives, a failure of the spindle motor servo control could easily put it over that 55X disintegration limit. I bet the manufacturer would be interested in knowing about this incident. Think of what a good slicky lawyer could do with it. :)

    CDROM spins continuously even when not in use

    The complaint may be that it sounds like a jet engine all the time and is annoying or just a matter of curiosity. I don't know whether it is normal or not for your combination of hardware and driver, but CDROM drives rated above about 12X are typically CAV (Constant Angular Velocity) - they run at a constant speed - not CLV (Constant Linear Velocity) like normal audio players (though they may drop into that mode when playing audio CDs). (The X speed rating is a MAX and you only get this performance for the outer tracks (which may be the later files in the directory unless they specifically placed them).
    Thus, your 24X CDROM drive actually spins the disc at a constant 4,800 rpm or so and you only get the specified access times if it is already spinning. Therefore, by one argument, it makes sense to keep it spinning whenever a data disc is in place. Also see the section: CDROM drive speed - where will it end?.

    Golden ears and technohype

    You have no doubt encountered various claims of how player A uses such-and-such a technology and therefore clearly has superior sound compared, no doubt, with all others in the explored universe. There may be people who can hear such differences in noise, frequency response smoothness, and such. Perhaps even you could hear a difference under ideal conditions. However, once all the variables that make *music* are included - the chain from artist and recording studio, microphones, recording, mixing, and resampling as well as your speakers and room acoustics - not just sinusoids played in anechoic or resonant chambers, the very slight differences between players are virtually undetectable to human ears. If you are interested in playing test discs all day, then worry about the last percentage point of noise floor or frequency response. If you really want to enjoy the music, this stuff should not bother you. There are more important things to worry about than an undetectable blip in your CD player's frequency response curve. Anyhow, with the introduction of the DVD technology pending, your carefully optimized ultimate stereo system will be as obsolete a year from now as a 78 turntable. Consider that! Only PC technology has a shorter lifespan. I bet you won't sleep tonight. :-)
    I would be curious as to the results of any true double-blind listening tests comparing CD players implemented with differing technologies (analog vs. digital filters, 4X or 256X oversampling, 1 or 2 D/As, etc.) on actual music (not test tones) in realistic listening environmemts. Such tests should be with people who are interested in the overall musical experience and not just the nth decimal point of technological specsmanship. There must, of course, be no vested interests (financial or otherwise) in the outcome of such tests. I would bet that the results of such tests would make for some fascinating reading and surprises for some manufacturers of high-end audio equipment.

    That last little decimal point

    Someone was hyping his high-end CD player (with a stratospheric price tag no doubt as well) claiming that it uses **mechanical** relays instead of transistors to perform the muting function (between discs or tracks) in the final audio amplifier. These mechanical relays are supposed to have less capacitance and thus not affect the 'fluency' or some other equally meaningless non-measurable characteristic of the sound. According to the same article, "only cheap CD players costing less than $900 use transistors for muting. All more expensive players use relays". If this claim is true, then how can manufacturers claim a +/-0.3db response curve from 20Hz to 20kHz even for CD players costing a lot less than $900?
    Well, my 10 year old Technics SLP-2 uses relays and it sure cost a lot less than $900. Shall we do a little calculation: Parasitic capacitance, say 100 pF (much much larger than likely). Highest frequency of interest: 20 kHz. The magnitude of the impedance of this parasitic capacitance will be:
      |Z|=1/(2*pi*f*C) = 1/(2*3.14159*2E+4*1E-10) = 80 K ohms
    Compare this to the output impedance of a typical final audio stage, say less than 1 K ohms (usually a lot less, but this will do for a back-of-the-envelope calculation). Yeh, right, I will loose a lot of sleep over that. There are better things to worry about than an immeasurable blip in your frequency response curve: Are the transistors at the very output? Oh my gosh, you better start investigating super ultra low capacitance audio cables costing at least $1000 each with water protected oxygen free tapered oriented strand conductors. But wait: you are connecting to an amplifier with non-infinite input impedance (perhaps, horrible as it may seem, non-uniform as well)? Your setup must sound like crap! How can you even have it in the same house with you? There are so many variables involved in the reproduction of high fidelity digital audio that this is about as significant as a pimple on an elephant. Ask for a scientifically designed and implemented A-B comparison. You won't get one because the revelations might be too shocking for the audio industry should the 'Golden Ears' fail to reliably distinguish between players at the two ends of the price spectrum.

    Totally worthless gadgets for CD enthusiasts

    Here are descriptions of a few of the items sold to born-every-minute suckers to improve the performance and audio quality of their stereo systems with respect to CDs. (These are strictly CD or digital audio related. There are many many more for general audio 'enhancement'.)
    Save your money. This stuff is total garbage:
    • Sonic rings to put on your CDs to stabilize them. The argument goes that this reduces wow and flutter by helping the servo system. There is none to begin with since pitch is determined by a quartz crystal. Note: these may even make your performance worse due to the added inertia of the rings. In addition, any added thickness could cause mechanical problems with some players like Pioneer changers (cartridge type) - loading, unloading, or during play.
    • Magic markers for used on the edge to reduce errors. The rational is that the colored edges will absorb any stray laser light and minimize interference with the main readout beam. Forget it. Such reflections are very minimal. Furthermore, the digital processing means that if there is a slight drop in the signal-to-noise ratio, there will be no - zero - audible effect.
    • Special digital clock you sit near your stereo to improve sound. I have no idea of the basis for this but I heard about it on a supposedly serious audio show. To clarify, I am talking about a time-of-day clock as in 12:34:56 with LEDs that has no direct physical connection to the audio equipment, not some high precision atomic cesium beam time-base unit! Perhaps, the added digital noise floating around will add some dithering to the signals and improve linearity? Right.... :-).
    • Special cleaning solutions. Soap and water just isn't good enough for Golden Ears. No doubt, CDs should be stored under pyramids as well for optimal longevity.
    • Fiber optic patch cords to reduce phase distortion. No kidding, I am sure there is at least one biological life-form in the universe that could detect the nanosecond or so phase shift introduced by the ordinary copper variety used by the rest of us. You don't suppose all the electronics involved will introduce any distortion of its own, do you?
    I recently was sent one of those audiophile magazines, and out of all the really stupid things advertised there, these two I found the funniest:
    • A demagnetizing CD. Play this on your system and it is supposed to demagnetize your equipment and make it sound better. The one I have seen the ad for claims: 10 times the effective demagnetization of other discs. Less than 1/100th the heat dissipation (!!!??) of other discs. Complete demagnetization of all frequency selective circuits. The fax I got was pretty funny. They claim on their fax that it also removes residual magnetism from the slight impurities present in the copper wires. (Maybe it will degauss my TV! --- sam) Of course, the disc is made with 99.999% pure 24 karat gold (for a higher reflected signal level, whatever that means). (This, too, is of course bogus. Gold will have the same or lower reflectance at the IR wavelength of the CD laser. It just looks way cool. --- sam).
    • Special solder, which tells you to remove all the solder on your amplifier, and redo all of it with this "Wonder Solder UltraClear". "For mere pennies you can solder (or reflow) a whole amp or speaker, and make it sound like one twice as expensive". (Sure sounds like a fun project to me - solder reflow in your toaster oven! --- sam).

    More on CD enhancers - magic markers and anti-vibration disks

    "I just had to comment on what you said about CD enhancers. I had the opportunity to test both a special green magic marker and a plastic anti-vibration disc that you stick on top of the CD to improve sound. The magic marker didn't work but the anti-vibration plastic did work. What I heard it do was enhance the spatial quality of the music. The separation was better. It sounded like the various instruments were a good foot or two farther apart on each side. That said, the demo was conducted on a $20,000 stereo system and I felt that $50 for the plastic disc was a bit high and I wasn't convinced that I could hear a difference on my more modest system."
    Sorry to be skeptical - go do an A/B comparison. Unless that player has an excessive error rate - and I doubt that to be the case with a $20,000 system - there is simply no way that any meaningful difference is possible. A CD is not like an LP - small variations in speed are irrelevant and thus improving the stability or whatever is also irrelevant. The data readout is fully buffered - meaning that even if there is wow and flutter or vibration in the CD rotation, it does not matter. Show me a double blind A/B comparison and I will reconsider. For now, the physics doesn't make sense. The guy doing the demo wasn't by any chance trying to sell $50 disks, now was he? :-) And, no, I have not done a double blind test. But, I would not mind being proven wrong. Just that based on the physics and technology, unless the CD player had a high error rate to begin with due to an underdamped servo system - he could have jimmied it - then there simply is no basis for expecting such things to improve a digital datastream. If the error rate decreased due to his discs, then perhaps there would be some sonic improvement. But, it should not have been high to begin with. Error rate reduction is the only possible mechanism I can think of to explain any possible audible differences. However, virtually all errors due to disc imperfections and scratches are *fully* corrected and thus undetectable in the output by human or machine. BTW, was he also selling $1,000 speaker cables? Go to engadget.com and search for the article "Audiophiles can't tell the difference between Monster Cable and coat hangers". :-)

    Why is speaker cable like spaghetti?

    (From: Keith Mayes (Mayes@d-m-g.demon.co.uk).)
    A survey was carried out in the 70's. People were given two bowls of spaghetti, one coloured blue and one coloured spaghetti colour. Most people claimed to prefer the taste of the spaghetti-coloured spaghetti. This was a real effect, with real people who had nothing particularly to gain or lose either way. Naturally, there was no instrumentally measurable difference in flavour between the two types. The same applies to speaker cables. People who have fancy cables will quite probably hear an improved sound, in their judgement. There is more to perceived sound quality than vibrating eardrums. Someone who has already bought fancy cable will not appreciate this story. If they hear an improved sound, then that's their good fortune. Someone who is considering buying fancy cables may well benefit from this story. It may save them a small fortune. In reality, the Emperor's response to being told that he was naked was:
    1. Deny it and prove it with signed affidavits.
    2. Have the kid locked up under a section of the mental health act.
    To believe in the power of a fancy cable surely pales into insignificance beside belief in a deity, and there are plenty of people who go for that.

    Can a CDROM disc damage a CD player?

    Some CDROMs include audio tracks that are entirely playable. However, data-only CDROMs may not even be recognized by newer CD players. With older ones - designed before the CDROM standards had been developed - the player may come up with a bogus track directory. Attempting to 'play' such a disc will probably not damage the CD player but will sound, shall we say, strange. I have done this and it really gets pretty boring pretty quickly. But, like pointing the camcorder at the video monitor, is something that is irresistible to try once. If you do this experiment, TURN DOWN THE VOLUME!!!. None of the rules which govern real-world audio frequencies and amplitudes are obeyed with data discs. You may blow out your speakers (or ear drums) if the volume is set too high or even at normal listening levels. I wonder what WIN.EXE or vmunix really sounds like!
    Another less common possibility is that a CD-R or CD-R/W that was aborted during writing (or damaged CD or CDROM of any variety) could result in the reader to repeatedly attempt to access a non-existent tract causing excessive sled movement - possibly even into the stops. This *could* conceivably result in overheating of servo components and motors and permanent damage though I've never heard of this happening. More below.

    Notes on Killer CDs and DVDs

    I am not referring to popularity, but rather instances where a defective CD or DVD can either lock up a player or drive, or in the case of some DVD-R or DVD-RW drives, even destroy the drive.
    The latter case has occurred (Fall, 2002) and involves certain DVD-R and DVD-RW drives using Pioneer pickups and electronics. See New Scientist. (Sorry, the original direct link died.) In short, a firmware bug in over 1 million Pioneer CD-R and CD-RW drives (Some Macs use these), and stand-alone players and recorders, may result in a burnt out laser when attempting and failing to recognize new high speed blank media. Apparently the firmware went in before the standard was fully developed (or at least fully debugged!). There is a firmware patch to fix the problem in existing equipment. A normal CD player or CDROM drive could lock up but would probably not be damaged except by physically damaged media (e.g., a broken disc catching on something or disintegrating at high speed) but in principle, the same could happen to CD-R or CD-RW drives. However, I am not aware of any such problems. (From: Dave Platt (dplatt@radagast.org).) I have seen situations in which these new "copy protected" discs have caused CD players to lock up quite seriously. These have been in cases where the CD player was based on a CD-ROM mechanism (i.e. an "internet appliance" type of device). Some of the new copy-protection techniques work by creating an invalidly-formatted multisession disc. A standard Red Book audio CD player won't even try to look for the second session, so it'll play the disc just fine. A CD-ROM drive - or any appliance based on one - will see that the disc is multisession, try to read the second session header, and become badly confused by the misformatted disc. In one case I witnessed, the CD-ROM drive's firmware became "stuck in a loop" trying to locate the malformed sessions. It never succeeded in accessing the disc, and it refused to respond to the "eject disc" button or the eject commands by the unit's control software. The only way to get the disc out of the drive was to shove an unfolded paper clip into the "emergency drawer open" hole in the front plate. I've been told that many of the higher-tech car CD players actually use CD-ROM mechanisms and the "rip the data" method of playing, in order to allow the data to be spun at higher speeds than 1x and then buffered in RAM. This allows extremely good bump/shock protection. If this is the case, then I expect that these types of car CD player will be unable to play these "copy protected" discs. Worse yet: imagine what will happen if such a disc locks-up the firmware in a slot-loading CD player which doesn't have an emergency-eject paper clip hole?! Put the disc in the player, it swallows it, the CD player freezes up and won't give the CD back, and you've got a useless CD player which requires a trip to the dealership for repair! If this does, in fact, ever happen, I fully anticipate that some savvy lawyer will arrange to file a huge class-action lawsuit against the disc manufacturer, on the grounds of "strict liability". The disc manufacturer "knew that these discs were deliberately manufactured in a way which would 'freeze' certain types of CD player, and knew or should have known that this could result in expensive damage to certain types of CD players." I'm heartened to note that Philips has put the disc vendors on notice that these discs *cannot* be caused by the "Compact Disc" name, or use the Compact Disc logo, or promise Compact Disc compatibility, since they do not meet the standards required by the license agreements.

    Performance testing of CD players

    The question arises: "How do I determine if my new, newly acquired, newly repaired or adjusted, or other CD player is actually performing up to specifications?".
    Note that in this section I am not addressing questions like: "Is my THD less than 0.003% (or whatever)?" but rather general usability issues like immunity to disc defects. If the music sounds right, the audio circuits are working. Subtle problems with the audio circuitry are rare. The best approach is to use the test disc(s) that most manufacturer have made available for their own CD players. However, this is probably an unacceptable expense unless your repair volume can justify it. No single test disc will be suitable for all brands. One problem is that CD players from different manufacturers (and even models from the same manufacturer) have varying amounts of tolerance to CD defects and varying levels of error correction (by design). Therefore, what plays on one may result in dropouts or skipping on another. Without the test discs, no quantitative measurements can be made. However, general types of tests can be done. My general recommendation would be to use a good quality music CD which is a full 74 minutes (e.g., Beethoven's 9th Symphony) to test basic seek and tracking capabilities. Exercise the player with track-track and full disc seeks in both directions to confirm stability and that none of these times are excessive. Evaluate bump immunity with your calibrated finger tap at the start, middle, and end of the disc. Also see the sections: "Comments on test discs" and "Custom test CDs using CD-Rs". Want to have fun? Find a garbage CD - one you don't really care about - and add imperfections of your own to the non-label side - using it as a frisbee or hockey puck should qualify. I would also suggest smudges but these are not permanent and what we want is something that will not change over time. Maybe try some fine sandpaper or steel wool. Painting fine strips of black radially (up to a width of 2 mm or so) may also be instructive though in reality, although the error correction may be capable of dealing with these, there may still be skipping or other mistracking. As long as the CD does not have any edges for the lens to catch on (it is not cracked or broken), there is little risk to your player. Scratching through the label side to the pits (information) layer may also be intersting. In this case, the data and tracking will be affected directly since the benefits of the out-of-focus surface (the non-label side) are lost. With this 'scientifically designed test CD' you should be able to gain a feel for how your unit-under-test compares to the CD player you normally use. However, don't be too disappointed if one or the other falls down in some respect. CD players are just not all designed alike. You may find that your $100 portable doesn't even hiccup on defects that send your $1000 audiophile model (which you thought was the ultimate in the state-of-the-art) straight to the showers. Finally, if you take reasonable care of your CDs (and don't position the CD player in front of your Megablaster-1000 speaker systems, you won't be 'pushing the envelope' during normal use and your CD player will not have to deal with marginal discs and vibration that often. For more fun, see the article: "Where is CD Date Physically?".

    Comments on test discs

    "Is a special expensive test CD needed for typical servicing? Can anyone recommend a test CD disk. I want test tones more than recorded music, single note sinewaves rather than sweeps."
    I ordered one from MCM Electronics called the "Diagnostic Test CD" for about $5. It has over 40 tracks mostly of pure tones (sinusoids) of various pitches (frequencies) and amplitudes. However, as noted below, an appropriate test disc is more likely to be useful for evaluating tracking performance than for audio distortion problems. Any music CD will suffice for the latter - these faults are usually quite obvious even to your average chimpanzee (or someone who is tone deaf). Test discs like the following will provide nice quantitative info and should be useful in comparing the defect tolerance of various CD players. However, you will need to know what the specifications are of the player-under-test to really be able to determine if it is performing properly. 

    Custom test CDs using CD-Rs

    With the continuing decrease in the prices of CD-R recorders, this approach will likely become much more common. If you have access to one at work, then there is no problem - it is probably not being used for its intended purpose anyhow :-). The only caution is that since CD-Rs are not quite the same as CDs in terms of optical behavior, some adjustments may not be optimal and should be rechecked with a normal CD or test CD.
     I have created a test CD using a CD-R. Using a program like Cool-Edit you can create perfect waves of different frequencies and amplitudes, silence tracks, and nearly anything else. With a program like Disc-at-Once delays can be added between tracks. After you burn the CD, holes can be drilled in the disc as well. I left a 2 minute gap between adjacent tracks so I could see the spaces between tracks. Drilling holes from 0.2 mm to 2 mm with 0.2 mm increment is allright. The disc is fantastic and it was made to fit my needs.

    Controlling the pitch of a CD player

    While it is easy to vary the pitch of a turntable or tape deck by controlling motor speed, this will not work with a CD player.
    Spindle motor speed is only loosely related to audio pitch. CD players use Constant Linear Velocity recording, meaning rotational speed varies from inner-most track to outside track. Reading a CD is more like transferring data from a hard drive under computer control - there is extensive buffering and the instantaneous spindle speed is not the main factor that determines pitch. For this reason, wow and flutter are generally so small as to be undetectable even with audio test instruments since readout is controlled by a very stable quartz crystal master clock, not anything electromechanical. Digital audio data is read from the disc into a FIFO (First in First Out buffer). Various processing is performed including decoding and error checking/correction and it is then fed to the DACs at a constant rate (determined by a crystal). If the FIFO gets too low, the motor speeds up. If the FIFO gets too full, the motor slows down. Very simple. Change the rate that data is read and the motor follows right along (up to a point). The actual frequency of the crystal varies from design to design but a typical value is 11.29 MHz (256 times the audio sampling rate of 44.1 kHz. If may be possible to substitute a variable frequency oscillator for the crystal to provide some amount of pitch control. With care and possibly some tweaking of the PLL servo adjustments, a pitch range of +/- 6% (about 1 semitone) should be possible. Some commercial CD players may do +/-12% such as the Technics SLPD-967 and some people have apparently achieved as much as +/- 20% by substituting a variable oscillator. But beyond this, strange things will likely happen with the spindle servo and the anti-aliasing (analog) filter. However, a schematic is really needed - and possibly more like chip specifications - to determine if simply injecting an external oscillator signal will work. Where a large change in pitch is desired, it may be easier to convert a CD player having an anti-shock memory since that capability means that the system inherently only calls for data when it needs it and actually reads the data off the disc at a much faster rate (e.g., 2X or 4X). This would also be the scheme used in players designed with a large range of pitch control. In any case, locating the clock that controls data readout (rather than the main microcontroller) would be the place to start. That may use a separate crystal. The more completely the player is based on digital processing, the less aliasing and other funny speed related effects will be present since everything will scale equally with readout rate. The only changes that may be needed to eliminate aliasing effects may be to the output antialiasing filters and may just be one or two capacitors in each channel. Needless to say, a schematic will be highly desirable. All in all, transferring the audio to another medium that allows for easy pitch control would be a whole lot simpler! There are cassette decks that can provide a 2:1 change in pitch while maintaining reasonable audio quality. Or convert to MP3 and do whatever you want in software. :)

    Converting a CD player into a CDROM drive

    Why anyone would seriously consider this project other than for the curiosity value is not clear, but the question does seem to pop up from time to time.
    If you mean audio making a CD player into a CDROM drive. Forget it. Don't waste any neural bandwidth on such considerations. While the optics and front end electronics are similar, the CD player is missing the circuitry needed to decode the CD data, CDROMs used more involved error correction, the control inputs are not there, and it is virtually impossible to obtain detailed schematics or firmware listings. And, in the end, it would be a state-of-the-art 1X drive since the servo systems and motors in an audio CD player are not capable of operation at more than 1X speed. Unless, that is, you are willing to butcher a CD player with an anti-skip buffer! :) You can probably pick up a 1X CDROM drive for $5 or less probably much less, like free. They practically come in cereal boxes these days (or was that 1G hard drives? Technology moves so quickly). Similar comments also apply to the nth degree with respect to converting a CD player or CDROM drive into an MPEG video device or something more exotic.

    Using a CDROM drive as a stand-alone CD player

    Since nearly all CDROM drives are capable of playing audio CDs, a natural question is whether it is possible to just supply power and be able to use an old 1X (or 2X or 10X) CDROM drive as a CD player without attaching it to a computer.
    For many types, the answer is yes. These provide some way of starting play and moving between tracks on the front panel. Usually, this is a pair of push buttons which combine play, eject, and next track functions or a volume control that can be pushed to start play and move to the next track. All these CDROM drives usually need is power to operate as audioCD players. For headphone listening, just use the front panel jack. A suitable adapter will permit the line outputs in the rear to be connected to the CD or AUX inputs of your stereo system. Some will automatically play CDs upon powering up or closing the drawer if a jumper is set properly. The Eject button will then control play, track selection, stopping, ejecting, depending on how long it is held down. Where the drive does not have these features, this may be more difficult.
    • It is probably not worth it for SCSI or IDE drives as special commands will need to be set up.
    • I don't know how difficult it is with the custom interfaces like Sony and Mitsumi. These may have a simpler command set but I doubt that it is just jumpering a signal to ground somewhere. Some logic will likely be needed to allow the drive to play music CDs but it should not be that complex.
    Note that the audio performance of CDROM drives is usually a notch below that of the typical audio-only CD player. The audio circuits are basically an afterthought for a CDROM drive. Therefore, don't expect quite the same level of frequency response, dynamic range, and lack of noise as your are used to with your stereo system or even your portable CD player. Of course, in a Jeep, this may not matter much. In addition, the bump immunity is probably not spectacular - PCs are usually not expected to deal with pot holes. Therefore, unacceptable rates of skipping and repeating may result if a converted CDROM drive is used in your car or back pack. However, some people claim to have used retired CDROM drives in vehicles with great success (see below). Therefore, it is worth a try if your model doesn't require a PC to be dragged along to play music CDs! CAUTION: Since the interface (if unused) will be disconnected, some people have expressed concern that leaving the inputs floating may be bad for the circuitry and/or that they will pick up spurious signals resulting in erratic behavior even if just using the front panel buttons. Therefore, it may be worth identifying the inputs and tying them inactive (pullup or pulldown as appropriate). I don't really know if this is ever a problem - just something to consider. Well designed systems *should* already have this built-in to handle the case where the cable becomes disconnected accidentally

    SP/DIF is common on most newer ATAPI CD and DVD drives, and specifically very rare on SCSI drives.
    Toshiba, Teac, Panasonic, etc, have SP/DIF. I think the long term idea is to eventually drop the headphone output and DAC in the CDROM and route SP/DIF to the sound card which will, or is being put on the motherboard. I have a number of new motherboards with SP/DIF inputs but I have not yet tested them in this mode. I know that the digital performance of the sound chip used on these particular boards (the HT1869) is horrible. Hopefully, somebody will do it 'right', as this is technology with promise. I've tested some CDROM's SP/DIF output with external audio DACs and good quality sound cards with digital inputs and they work, pure and simple. The performance of a $80 CD ROM and a $200-300 DAC (specifically the Technics SH-AC-300) can eclipse more expensive equipment, in technical terms.

    Can I use the pickup from a CD player or CDROM drive for optical experiments?

    With the nice precision optics, electromechanical actuators, laser diode, and photodiode array present in the mass produced pickup of a CD player, CDROM drive, or other optical disc/k drive, one would think that alternative uses could be found for this assembly after it has served for many years performing its intended functions - or perhaps, much earlier, depending on your relative priorities :-).
    People sometimes ask about using the focused laser beam for for scanning or interferometry. This requires among other things convincing the logic in the CD player or CDROM drive to turn the laser on and leave it on despite the possible inability to focus, track, or read data. The alternative is to remove the optical pickup entirely and drive it externally. If you keep the pickup installed in the CD player (or other equipment), what you want to do isn't going to be easy since the microcontroller will probably abort operation and turn off the laser based on a failure of the focus as well as inability to return valid data after some period of time. However, you may be able to cheat:
    • If the unit has a 'Test Mode', it may be possible to force the laser to remain on despite a total lack of return signal - or even without the focus and tracking actuators even being connected, for that matter. Many models have a Test switch, jumper, or pair of solder pads on the mainboard (enable before powering up). Then, there may be a key sequence to enable the laser, move the sled, etc. See, for example, the section: Pioneer PD/M series test mode.
    Where such a feature is not provided:
    • First, whatever is used to detect a disc must be defeated. Usually, this is a reflection of the laser (most common).)but may be a separate sensor.
    • Then, the 'focus ok' signal must be provided even if you are not attempting to focus the laser beam. It may be possible to tie this signal to the appropriate logic level to do this.
    • Even if it is not possible to access these signals, depending on design, you may be able to locate the logic signal to turn on the laser and enable it there. However, some systems bury this inside a chip based on the controller to activate it. Getting a schematic will probably be essential - but this may be difficult (especially for a CDROM).
    It may be easier to just remove the pickup entirely and drive it directly. Of course you need to provide a proper laser diode power supply to avoid damaging it. See Sam's Laser FAQ in the chapter: "Diode Laser Power Supplies" for details. You will then have to provide the focus and/or tracking servo front-end electronics (if you need to process their signals or drive their actuators) but these should not be that complex. CAUTION: Take care around the lens since the laser will be on even when there is no disc in place and its beam is essentially invisible. See the section: SAFETY. Some people have used intact CD player, CDROM, and other optical disc/k drive pickup assemblies to construct short range interferometers. While they have had some success, the 'instruments' constructed in this manner have proven to be noisy and finicky. I suspect this is due more to the construction of the optical block which doesn't usually take great care in suppressing stray and unwanted reflections (which may not matter that much for the original optical pickup application but can be very significant for interferometry) rather than a fundamental limitation with the coherence length or other properties of the diode laser light source itself as is generally assumed. In any case, some of the components from the optical block of that dead CD player may be useful even if you will be substituting a nice HeNe laser for the original laser diode in your experiments. Although optimized for the IR wavelength (generally 780 nm), parts like lenses, diffraction grating (if present and should you need it), and the photodiode array, will work fine for visible light. However, the mirrors and beam splitter (if present) may not be much better than pieces of clear glass! Unfortunately, everything in a modern pickup is quite small and may be a bit a challenge to extract from the optical block should this be required since they are usually glued in place.

    Taking a CD player overseas (or vice-versa)

    Fortunately, the standard for the CDs themselves is the same everywhere in the explored universe. Yes, even Australia :-). Thus, there should be no issues of incompatibility. The differences will relate only to the power supply needed for your player.
    First, check your user's manual (which you of course have saved in a known location, right?). It may provide specific instructions and/or restrictions. Most component type CD players use a simple power supply - a power transformer followed by rectification, filter capacitors, and linear regulators. These will usually only require a small step up or step down transformer to operate on a different voltage. Since power requirements are minimal, even a 50 VA transformers should be fine. WARNING: never attempt to use one of those cheap lightweight power adapters that are not true transformers to go from 220 V to 110 V as they are designed only for heating appliances. They will smoke your CD player (or other equipment not designed to handle 220 V to 240 V input). Some CD players may have dual voltage power transformers which can be easily rewired for the required voltage change or may even have a selector switch on the rear panel or internally. The frequency difference - 50 or 60 Hz should not be a problem as nothing in a CD player uses this as a timing reference. The only slight concern would be using a CD player specified for 60 Hz on 50 Hz power - the transformer core may saturate and overheat - possibly blowing the internal fuse. However, I believe this to be a rather remote possibility. For portable CD players, if your wall adapter does not have a voltage selector switch, obtain one that is rated for your local line voltage or use a suitable transformer with the one you have. As with power transformers, a frequency difference may cause a problem but this is not likely.

    Sony portable service mode

    This applies to the D33 - don't know about other Sonys. At least only a single jumper is involved. On the D88, it was necessary to both remove one jumper and add another. After several of these cycles, the circuit board tracks started to disintegrate :-( How about pads for a microswitch which would be part of the standard Sony service kit?

    Remove the power supply (batteries or whatever you have) and the bottom cover. Now make a soldered interconnection between the two jumper TEST terminals and apply power again). Pressing the PLAY button should cause the spindle to spin continuously.
    That would make it easier to determine whether the motor is OK or not.

    Portable CD player Q & A

    The following questions and comments may give you a better feel for the considerations on attempting to repair a portable CD player (or CDROM drive for that matter).
    "I've read the relevant sections in the FAQ already. My problem concerns a Sony D-99 discman, it started skipping, etc., but within a matter of days degenerated to the point that it won't even read the TOC any more and is essentially dead. All the motors work fine. I'm assuming that the problem has to be something to do with the laser optical subsystem or its setup. The fact that it sort of worked for a while but rapidly degenerated suggested nothing has died totally but something has a terminal disease. I'm guessing either that the calibration has drifted to (and now beyond) the limits it can accept, or that the laser's power output is deteriorating. 1. Do lasers age significantly assuming they aren't abused as noted in the FAQ (i.e. turn into DEDS)?"
    They really should not 'wear out'. Certainly not in the span of a few days after having been faithful servants for several years. The quoted life of a typical laser diode is 5,000 to 10,000 hours. But that assumes proper drive There is no way of knowing for sure. FWIW, there is a disc player that I repaired for a mechanical problem that is used something like 8 to 10 hours a day, 6 days a week for the last 5 years or so. It is still going strong.
    "2. Since it is a small Discman, I worry a little that it will either go 'pling' when I take the back off (not that that ever stopped me opening things before) but more seriously there will be little I can do when I get in there."
    Portable CD players tend to be fairly well behaved when the covers are removed. However, I am not optimistic about your chances of repair. Some careful exploration should not harm anything (not that it is likely to matter). I have found from my experience with portables that working on those things is a pain. This is especially true of older Sonys where the mainboard is connected to the optical pickup with many fine soldered wires in addition to soldered in flexible cables.
    "3. Sony have *not* been helpful. They will likely charge me the same as it costs to buy a new one, which is a shame because this old girl is actually made of metal and I hate the horrid plastic feel of the new toys, even if the batteries last longer and it sounds as good. The Sony man himself said that the new ones are built down to a lower price."
    Forget Sony. If I interpret the model correctly, that one is fairly old. You would be lucky to get their attention for something 1 day out of warranty.
    "4. Should I pay the man?"
    The temptation of some repair places is to blame the optics without even doing any testing - which alone will set you back more than the price of a new basic player (well, it will do everything yours will do but weigh half as much!).
    "5. Should I throw it away?"
    That would be a shame but it depends on how much you value your time versus the cost of a new one. I really do respect the look and feel of those old Sonys. Needing to reseat internal connectors, dirty controls, mechanical problems, are still possibilities. Also, if you are using an AC adapter, make sure *it* is not the one that is terminal! However, adjustments may not even be marked and if it is now totally unresponsive, there is no way to really tweak them without a service manual.
    "6. Should I take the back off, nothing to loose, then most likely throw it away?"
    First, clean the lens and check the mechanics, and the AC adapter. Next, see the chapter: "Startup Problems". Then try to identify how far it is getting. This can probably be done without taking the back off. You can pretty much forget attempting to repair the circuitry - most components are surface mount - both very tiny discrete parts and large multilegged ICs. It is difficult to obtain data sheets for many of these. The service manual is not always complete enough to be much help. Even probing test points without shorting anything out or having the whole mess fall on the floor while balancing the guts of the player and pushing buttons typically requires a minimum of 4 hands.
    "7. Do I stand a chance to find someone who will give me a better likelihood of success at a reasonable price than the local sony man (who to be honest looks like his idea of repair is to replace it in any case, certainly on a module level)?"
    IMO, unlikely. It takes more time to get into one of those than a full size. Time is money, etc. They would probably have to order the manual which is an added expense that may never be useful for a future customer.
    "Sorry if 'throw it away' isn't in the spirit of things, but hey."
    Sometimes it is. :(
    "P.S., one improvement to the FAQ would be to outline the likelihood that things actually have worn/died with age, rather than simply how to adjust or repair something that just doesn't work for some reason. This one has had a lot of use over five years."
    Unfortunately, aside from things like grease gumming up or mechanical parts collecting dirt, optics getting coated with dust, tobacco smoke or cooking grease residue, motor bearings wearing out, the electronics and optics really should not age. Of course, there are all kinds of ways that this could happen through use and abuse (e.g., large dogs, toilets, and salt air) or bad design.

    CD players in vehicles

    Although a CD player mounted in an automobile or ATV is subject to much greater levels of vibration and shock than a home stereo (though perhaps not more than a well used portable), this may not be the primary factor affecting the long term survival of these devices. Other considerations are cycles of heat, cold, and humidity; dust and tobacco smoke; and the harsh environment of the vehicle's electrical system.
    Temperatures under the dash or in the trunk can easily vary from below 0 F to more than 110 F during the year. Humid and salt air are particularly nasty. The confines of the passenger compartment concentrate tobacco smoke products so the lens and optics may suffer more in this environment. While these must perform the same basic functions as their more stationary counterparts, there are some additional considerations:
    • Environmental - hot, cold, humidity, exhaust fumes, tobacco smoke. All of these can result in more wear and tear on the mechanism, temporary or long term problems.
    • Vibration - Unless you live in an earthquake zone, your home stereo system doesn't get bounced around much. However, in a car or truck, constant bouncing is to be expected. CD players designed to be used in mobile situations should have more robust and compliant shock mounts. This is one reason why using a surplus CDROM drive as a mobile CD player may not work well (but some will be fine).
    • Power - The quality of the power to the accessories is often pretty poor compared to a stereo system or PC. High voltage spikes may result in permanent damage if there is inadequate protection. Ignition noise may feed through to the audio and require special line filters or other means to reduce the whine or buzz to acceptable levels. Either of these may also result in erratic behavior.
    • Accessibility for repair - Finally, these systems are generally difficult to work on when repairs are needed. This includes removing the unit(s) from the dash/trunk, providing proper power and possibly control, and simulating the conditions that are causing the problems in the first place!
    Here is one example illustrating the additional uncertainties of these units:
    "I have recently install a Panasonic in-dash CD, My problem is the CD player does read and play but it will stop suddenly and eject itself, few of my friends have told me it could be due to dirty lens and I have seek a second opinion from a pro car audio installer and they told me is my lens is damaged and needs repair."
    The "pro car audio installer" probably doesn't have a clue but mentioning the lens is sure to impress - NOT! (From: Filip M. Gieszczykiewicz (filipg@repairfaq.org).) If you installed a *new* player, I doubt that this is the problem. Most likely, alas, is a wiring mistake or a bad connection. Did you follow the instructions and use the recommended wire harness adapter? Did you provide a good, solid ground? What wire-splicing method did you use? Did you tape/heat- shrink all connections? Did you mount the radio securely in the dash? Most car CD-players will spit out the disk when power is interrupted to them. Does it happen when you hit a bump or are going over rough road? Check over the wiring, then check the ground, but first check *when* exactly the problem appears! Take it for a test-drive over a bumpy road: does the light flicker before the disk comes out? Any noise from the speakers? (From: Steve Loboyko (sloboyko@mindspring.com).) Automotive CD players are more susceptible to smoke on lens. Also, highly variable temperatures make servo "center" adjustments tougher and critical on a car in-dash CD player. For example, I am starting to have problems reading gold/green CD-R's in my car if the interior of the car is hot. Gold/blue CD-Rs won't work at all. All work 100% fine in home audio or CD mechanisms. It will be a pain in the butt to fix, with a hair drier simulating the "normal operating temperature" on a 90 degree day.

    Who says CDROM drives are fragile?

    The average person thinks that a CD player or CDROM drive is a delicate piece of precision equipment that will die given the least excuse. Well, chalk at least one up for the good guys!
    (From: Joseph E. Fealkovich (jef812@ix.netcom.com).) My best friend calls me up, he works at a computer outlet in Cleveland, OH (figure it had to be Cleveland! :-) --- sam), to tell me he has a Teac CDROM he 'accidentally' ran over with a pallet truck loaded with about 850 pounds of DOS and Windows (who says software isn't a tangible asset! :-) --- sam). The CDROM drive is crushed a little bit in the rear, the faceplate popped off and skittered across the floor. Upon obtaining this CDROM drive, I look at it and yes, the back part is pretty well damaged. Me and my good friend Timmy take this poor unit apart to look at the insides. I'll be damned, there is no internal damage whatsoever. All that has to be done is straighten the main chassis of this CDROM and straighten out the outer case. While I was at work straightening out the CDROM, I hit Teac's website to get the drivers for this CDROM, and I'll be double damned, IT IS A 16X CDROM DRIVE!! COOL! The model number is CD-516E, cool, if I get this gem working, I can put it on my secondary port on my 32-Bit IDE interface. Sure enough, I straightened out the crushed case on this unit and I install it with the drivers I downloaded from Teac's website. This CDROM works like it was brand new!:-) WOW, is this damn thing fast! COOL, I got a free 16X CDROM, all I had to do is fix the damaged case and chassis!:)

    Most expensive replacement part of the century award

    This is right up there with $400 hammers and $20,000 toilet seats :-)
    MCM Catalog #38, page 500: Original Aiwa/Sony Spindle Assembly: $94.50(ea). It is part number 32-7275 if you are eager to order one ;-). From the picture, this is the type of spindle assembly used in the typical $70 portable CD player or cheap (by now obsolete) CDROM drive - a $1.99 Mabuchi style motor (two pin connector included!) and plastic self locking spindle platter glued or pressed to the shaft. Do people actual pay this???? Why would anyone spend almost $100 for one of these replacements? Yes, I know most of the answers. The question is to stimulate discussion.

    Comments on Sony KSS pickup suspension problems

    There seems to be some debate as to what extent weak suspension contribute to uncorrectable (by the internal adjustments) skipping and other erratic behavior. However, it is generally agreed among those who actually have to repair CD players and CDROM drives using Sony KSS pickups that such deteriorated suspensions can indeed be a cause of a variety of problems.
    (From: Mark Z.) Anyone who has worked much with these units knows that the suspension can be a factor, especially where a player is somewhat finicky about which discs it likes or doesn't. This is particularly true of the D- series portables. I call attention also to the Denon DN2000 type dual players which use the KSS240A optic. Replacing the pickup seems to *always* fix these type of erratic skipping problems. There is no way I know of to tell for sure that the focus bias or other adjustment won't get it back into nominal area of operation, other than just trying it. In fact, adjusting the focus bias (focus offset) is often done to get the player into a better operating area, and to save the expense of a new optic. With a player say, 4 to 5 years old, the actual deterioration may be quite minor, and the adjustment may be all that is needed. Of course, if if it is really that minor, why was it acting up in the first place? I disagree with Sony on the issue of deterioration. I've seen too many examples, particularly when the objective lens is 'bottomed out'. If the focus servo is really able to overcome this physical problem:
    • The focus drive electronics, transistors, IC, whatever will run unnecessarily hot. These circuits are designed to have a zero average offset to lower average power dissipation.
    • Why then does the RF signal look so bad on players where the disc table is installed at the wrong height by as little as 1/2 mm?
    However, most skipping, sticking, repeating, and similar symptoms are still caused by feed problems and spindle motors. Sony is correct to state that many pickups get replaced unnecessarily. I attribute this to inadequate technician training, and also that CD players work by FM.... (F***ing Magic). tech humor. Ha. Ha :-).

    Enhancing the sound quality of an inexpensive CD player

    OK, this isn't for everyone. But, if you have the electronics experience and desire, it may be possible:
    As we all know, reading errors are NOT main problem in CDs (as I know it is not a problem at all. I checked this in my old Technics). What really making some of them sounds so bad are awful output states and analogue filters. Sound of some cheaper players can quite easily be improved by changing these crappy output states and filters. When I recognize this I went to the market and I bought old second- hand Technics (or Matsushita) SL-P550 for a rather low price. I chose this one because it had the good optical deck (linear motor and three points spring suspension) and generally was in good condition. Then, it was extremely easy to find all signals on electronics board, as most of them are marked (what an idea!) and most important ICs are "typical" and easy to find in catalogues (it does not mean that they are good). Finally I decided to change everything from digital filter to the output. I bought NPC 8x oversampling filter, Burr-Brown DACs and designed my own analogue lowpass filters and output states. I still don't know much of a problem jitter is, but I wanted to make a really HiFi CD, so I throw away the 16.9344 MHz crystal and connected XTI pin of main laser receiver/decoder to the separate low jitter oscillator. For connections from main board I used short wires soldered directly to electrical paths, and then connected to my own circuits. It is funny how a few signals were needed (Data In, Bit CLK, L/R CLK, and System Clock - all can be found directly on Yamaha digital filter on main board). I also change (upgrade) the power supply and add a display on/ off switch. I think that almost every CD (maybe not small portable units) can be upgraded in this way, but be careful - CDs are usually NOT the limiting components in stereo system. You need a really good one to hear the difference in between them.

    Impress your friends with the power of your CD player

    The laser output of the typical CD player optics is less than 1 mW but since the beam is focussed to a diffraction limited spot of less than 2 um the resulting power density is truly impressive:
    (Portions of the following from: James Carter (jcarter@photon-sys.com).) Intensity is related to power by the 'area' of the beam. For a Gaussian laser (as most semiconductor lasers are), the 'area' of the beam is related to the area of the intensity contour (usually an ellipse for these guys) representing 1/e^2 or approx. 13.5% of peak intensity (at the centroid). Thus the peak intensity occurs at the centroid and equals
                 2 * Po
       Io  =  ------------
              pi * Wx * Wy
    
    Wx and Wy are the beam semi-diameters for the 1/e^2 contour. The beam size at the facet of a semiconductor laser can be as small as 1.5 by 3.5 microns. The high power density at the facet represents the cause for most common failure modes in laser diodes. For a 5 mW laser diode, the resulting power sensity on this facet can be in excess of 600 MW (that is Megawatts) per square meter! Sounds impressive, doesn't it? At the CD, the spot is even smaller which for the same power would result in even higher densities. However, this is more than offset by the fact that a significant fraction of the original power is lost in the optics so the the power density might be only - 300 MW per square meter. I still would not recommend hanging out at the focal point! Note that while these numbers are impressive, conduction and other losses generally prevent any actual damage from occurring to most common materials. However, in a CD-R recorder using a laser diode with a power output of similar magnitude, the temperature rise at the disc even while spinning at 4X or greater speed is sufficient to blast holes in the intermediate (green) information layer. Watch out!

    CD to VCD converter? 

    They can convert cheap CD players selling at RM200-300. The converter just took the signal coming from the amplifier after the CD head. And the output is RF signal for the TV. I once saw one of these cards to have a 8051 uC on it and I don't really know how the thing works. They also do mods on LD players and it works well with the remote control on the LD player.

    Modifying CD player to get at data stream? 


    A couple of years ago Elector electronics magazine published several articles about add-on items for digital audio. They also published a construction article for making a CD player.
    The data stream is called SPDIF (Sony Philips Digital Interchange Format). This is the same data stream format that you'll see at an internal node on every Sound Blaster card. It is not just audio waveforms encoded as numbers. It also can contain the copy bits, and perhaps other stuff. I believe that it is a 24 bit data format, even though the data on the CD itself is only 16 bits. Philips and SGS Thomson make neat consumer IC's that process this data stream in various ways. Again see the back issues of Elector for more information. If you cannot find them, let me know by email and I'll search my archive.

    Designing CDROM reader to recover data from damaged CDs, CD-Rs, or CD-RWs

    A disc/k which has been cracked or some of the coating has peeled off, may be totally unreadable, especially if any of the damage is in the directory area.
    In principle, you could design a CD reader that would get most of the data in the areas that are not damaged. It would have to read slowly so that focus and tracking lock could be reacquired after skipping the damaged area. Whether a normal CD reader could be modified I don't know, it might take custom circuitry to rotate the disc at a programmable slow rate and pick off the raw data. Decoding and reconstruction could be done in software. It could be a big project with questionable returns. There would still be major gaps and with data, that could be bad news. This is worse than attempting to recover data from a magnetic disk (diskette or hard drive).

    Arfa's Comments on DVD Player Optical Block Testing and Replacement

    In general, there's not an awful lot you can do to 'test' an optical block, as such. In general, if the unit plays CDs but not DVDs, or, more rarely, the other way round, you have a better than even chance that it's the laser (optical block) that's at fault. If your player is used a fair bit, then 3 years is not at all uncommon for the laser to be showing signs of wear. Another good pointer is if the player starts freezing up after about 3/4 of a full length feature film has played. This is when the player has switched to reading layer 2 on the disc, which has to be read through the semi-transparent layer 1, so consequently has less reflectivity of the laser beam.
    Other causes of poor playability are bad spindle motors, when they are the brush geared little Mitsumi DC types, and (very) occasionally deposits on the outer surface of the lens, particularly if it's a heavy smoking household. Geoff in Israel also tells me that it is more common to have a dirty laser, if you live in a climate like his. As far as replacing lasers goes, on most players, it's not a difficult job. Often, the laser comes pre-mounted and aligned on a sub-deck, which also includes the spindle and sled motors, and limit switch. Where this is the case, it is pretty much guaranteed that it is just a 'drop-in' replacement. Some lasers are supplied as just a 'bare bones' optical block. In most cases, these will also just drop in, but some players, such as Panasonic for instance, require the tilt to be mechanically adjusted. Some other players have electronic setups to match in the replacement laser to the machine. Most machines also have a degree of self diagnosis built in, but it's often hard to get at unless you have a service manual, and sometimes a service remote. In my experience, unless you have a particular liking for a player, or if it's a HC system, and you have all its speakers and cabling 'plumbed in' to your walls, the cost of a replacement laser is prohibitive, and you might as well go and buy a new player, with a new 2 year warranty, at the cheapest place you can find...
     

    Exploration and Tinkering

    Interesting CD player signals

    Poking around inside a working CD player makes an excellent exercise for the student. Component CD players very often have clearly marked test points for RF, focus, tracking, and audio data. With care, there is little risk of damaging anything as long as you are not tempted to try your hand at tweaking any of the internal adjustments.
    If you have nothing better to do and you have your CD player open, try to locate the test points for data, fine tracking, and focus. They may be labeled something like TP.DTA (or TP.RF), TP.FO, TP.TR. TP.DTA or TP.RF is the data coming off of the disc having gone through only the photodiode segment combiner and preamp (probably). Using a 10:1 probe set the scope for a horizontal sweep of around 0.5 us/div. Try a vertical sensitivity of 0.2 V per division to start and adjust for a full screen display. Use internal positive triggering. While playing a disc, you should see the classic 'eye' pattern used in the communication world to characterize channel quality.

    The CD player 'eye' pattern

    The 'eye pattern' depicted below results from the characteristics of the run length limited 8-14 modulation coding used on the CD where there are no fewer than 3 and no more than 11 clock cycles per symbol. You should be able to make out the fact that the minimum distance between channel bits is 3 with the smallest distance between bit transitions of about 3*232 ns. The readout clock is 1/(232 ns) or about 4.321 MHz.
    A 'good' eye pattern will be clean, symmetric, and stable with clear visibility in the cross hatched areas. Its amplitude is typically in the .75 to 2 V range p-p when measured at the RF test point. This waveform may be viewed using an oscilloscope of at least 5 MHz bandwidth. Some typical RF amplitude specifications:
    • Aiwa: 1.3 to 1.4 V p-p.
    • Sony full size: 1.2 V p-p, auto and portable: 0.85 V p-p.
    This diagram shows the general form of the eye pattern present while playing a musical track or reading data from a CDROM. An actual scope trace from a typical CD player RF testpoint is shown in: CD Player Eye Pattern.
            ______________________________________________________
           /      \   \   \   \   \/  \/  \/  \/  \/  \/  \/  \/
          /        \   \   \   \  /\  /\  /\  /\  /\  /\  /\  /\
         /          \   \   \   \/  \/  \/  \/  \/  \/  \/  \/  \/
                     \   \   \  /\  /\  /\  /\  /\  /\  /\  /\  /\
                      \   \   \/  \/  \/  \/  \/  \/  \/  \/  \/
                       \___\__/\__/\__/\__/\__/\__/\__/\__/\__/\__
    
                            |<---- 1 us ---->| (approximately)
    
    
    Examination of the eye pattern would be the first measurement that would be performed to determine the condition of the CD player optics and electronics. A good eye pattern eliminates most of the parts of the optical pickup from suspicion. Note that the eye pattern observed while the player is accessing the following areas of the disc may not be well formed as in the diagram above:
    • Disc directory (Table of Contents or TOC).
    • Before the start of the first track (Track 1, time less than -0:01).
    • Between tracks of distinct selections (where there is silence).
    • After the end of the last track.
    This is because there is no musical data at these locations on the disc (but probably a constant value like 0) and the TOC and/or time display is obtained from the Q bit. The Q bit is part of the Control and Display byte that is present once per frame (14 EFM coded bits out of 588 total bits per frame). See the section: CD (disc) construction. This funny looking eye pattern has much more low frequency content and thus does not exhibit the nice cross hatched area as will be present with the highly variable audio data.

    Focus and tracking drive or error signals

    TP.FO or TP.FE is the focus voice coil error signal. Monitoring this with a disc in good condition will show what looks like noise - the more or less random fluctuations in actuator current necessary to maintain proper focus within +/- 0.5 um of the disc surface. On a warped disc you will see the DC level of this signal varying at the disc rotation rate. On a damaged disc, you will see higher frequency variations in the level depending on what kind of defects are present. Gently tapping the optical deck should evoke a visible effect on this signal as well as the servos correct for your mischief.
    TP.TR or TP.TE is the fine tracking voice coil error signal. As with TP.FE, this will show a noise waveform with a good disc. On a disc with runout, you will see a periodic level variation at the spindle rotation frequency. Note how the DC value of this signal gradually changes as the voice coil actuator maintains lock on the track while the track spirals outward. Eventually, this error becomes great enough to trigger the coarse tracking motor to jog the pickup a fraction of a mm and recenter it on the track at which point the signal you are watching will suddenly shift its DC level. On a disc with scratches, there will be higher frequency deviations which will be readily visible on a scope trace. Gently tap the optical deck from various points and observe the effects on this signal. For both focus and tracking, you can actually hear the voice coil actuators as they compensate for minute defects or just the normal data pattern. This is the 'gritty' sound one hears from the CD audio or CDROM transport when it is operating correctly and is an indication that the laser and focus (at least) are most likely functioning properly. If you listen carefully, you can actually hear various defects by the effect they have on this gritty sound but there will be no corresponding effect in the audio outputs as there would be with an LP.

    Focus, tracking, and error correction performance

    If you have a test CD (or use your regular CD), put your scope on one of audio outputs. Put some thin pieces of tape or mark with a (water soluble) felt tipped pen radially on the bottom surface of the disc to create some 'defects'. Play some tracks which have constant pure tones or silence. For widths less than the error correcting capability of your CD's LSI chipset, there should be no detectable signal degradation. See what happens as you increase the width of your 'defects'. Put your finger on the spindle or even gently touch the disc as it is rotating. Note that unless you really press hard, the disc will continue to play normally without any change in pitch. This is due to the servo control and extensive buffering of the data - unlike an LP turntable where the instantaneous speed is what determines pitch.
    Other experiments are left as exercises for the student.

    IR detector circuit

    This IR Detector may be used for testing of IR remote controls, CD player laser diodes, and other low level near IR emitters.
    Component values are not critical. Purchase photodiode sensitive to near IR - 750-900 um or salvage from optocoupler or photosensor. Dead computer mice, not the furry kind, usually contain IR sensitive photodiodes. For convenience, use a 9V battery for power. Even a weak one will work fine. Construct so that LED does not illuminate the photodiode! The detected signal may be monitored across the transistor with an oscilloscope.
     Vcc (+9 V) >-------+---------+
                        |         |
                        |         \
                        /         /  R3
                        \ R1      \  500
                        / 3.3K    /
                        \       __|__
                        |       _\_/_  LED1 Visible LED
                      __|__       |
            IR ---->  _/_\_ PD1   +--------> Scope monitor point
              Sensor    |         |
            Photodiode  |     B |/ C
                        +-------|    Q1 2N3904
                        |       |\ E
                        \         | 
                        / R2      +--------> GND
                        \ 27K     |
                        /         |
                        |         |
           GND >--------+---------+
                       _|_
                        -
    
    

    Inexpensive laser power meter

    In principle, a reverse biased photodiode and mA meter can be used to measure laser power. A silicon solar cell could also be used in zero bias current source (photovoltaic) mode. However, this is sort of difficult for CD and similar equipment which don't produce a nice compact collimated beam that can be directed at the photodiode without losing too much. The beam from the objective lens of CD, DVD, or other similar optical storage equipment is highly divergent.
    The conversion factor of current to laser beam power also depends on wavelength and the way the photodiode was processed. A typical silicon photodiode has a sensitivity of 0.4 to 0.45 mA per mW at 632.8 (HeNe laser wavelength, close enough for DVD). At 780 nm, it will increase to 0.5 to 0.55 mA per mW. More information on laser power meters can be found in Sam's Laser FAQ in the chapter: "Items of Interest".

    Laser diode fundamentals

    Note: This is a summary. For additional information on using laser diodes, see Sam's Laser FAQ in the chapter: "Diode Lasers".
    Typical CD laser optics put out about 0.1 to 1 mW at the objective lens though the diodes themselves may be capable of up to 4 or 5 mW depending on type. The laser diodes for CD players are infra red - IR - usually at around 780 nm. Visible laser diodes are also readily available from many sources. The most common wavelength is 670 nm which is deep red but 630 nm diodes are also available - red orange and appear much brighter (and more expensive at the present time). Inexpensive (well relatively) laser pointers use visible laser diodes with power outputs up to about 5 mW. This is enough power to risk permanent retinal damage if you look into the beam especially when well collimated as is required for a pointer. Don't. Typical currents are in the 30-100 mA range at 1.7-2.5 V. However, the power curve is extremely non-linear. There is a lasing threshold below which there will be no output. For a diode rated at a threshold of 80 mA, the maximum operating current may be as low as 85 mA. This is one reason why all actual applications of laser diodes include optical sensing (there is a built in photodiode in the same case as the laser emitter) to regulate beam power. You can easily destroy a laser diode by exceeding the safe current even for an instant. It is critical to the life of the laser diode that under no circumstances do you exceed the safe current limit even for a microsecond! Laser diodes are also extremely sensitive to electrostatic discharge, so use appropriate precautions. Also, do not try to test them with a VOM which could on the low ohms scale exceed their safe current rating. While only a few hundred mW at most is dissipated by the laser diode, a good heat sink is also important for long life and stability. The optical pickup is usually a metal casting partially for this reason. Remember that the active diode chip is only about 0.1 mm on a side. However, some optical blocks are now made of plastic so this must not be as important as in the past. It is possible to drive laser diodes with a DC supply and resistor, but unless you know the precise value needed, you can easily exceed the ratings. One approach that works for testing is to use a 0-10 VDC supply (preferably a linear supply - a switching supply may put out laser diode destroying pulses) with say, a 100 ohm resistor in series with the diode. Slowly bring the current up until you get a beam. Use an IR detector for this! If you get the polarity backwards or are actually measuring across the internal photodiode, the voltage across the diode will go above 3 volts or will be less than 1 V. Then, turn power off and reverse the leads. Note: some laser diodes will be destroyed by reverse voltage greater than 3 V - a spec sheet will list the reverse voltage rating. The ones I have tried out of CD players were fine to at least 5 V in the reverse direction. Without a laser power meter, however, you will have no way of knowing when the limit on safe beam power (safe for the laser diode, that is) is reached. If you have the data sheet for your laser diode, then the best you can do is limit the current to specified maximum rating. Also, there is usually a weakly visible emission which appears red (for IR laser diodes) present when powered. Do not be fooled into thinking that the laser diode is weak as a result of this dim red light. The main beam is IR and invisible - and up to 10,000 times more intense than it appears. The beam from the raw laser diode is emitted in a broad wedge typically 10 x 30 degrees. A convex lens is needed to collimate the beam (make it parallel). For optimal results, this needs to be anamorphic - unequal horizontal and vertical focal lengths - to correct the astigmatism of the beam. The mass produced optical pickups used in CD players include this as well as other sophisticated optics. For an actual application, you should use the optical feedback to regulate beam power. This usually takes the form of a simple current controlled power supply with extensive capacitive filtering and a regulated reference. It is possible to modulate the beam power by tapping into the feedback circuits - as long as you guarantee that the maximum current specification will never be exceeded. Laser diodes do not behave like LEDs and cannot be pulsed for higher peak power - they turn into DEDs - Dark Emitting Diodes. Single chips are available from a number of manufacturers for driving laser diodes in both CW and modulated modes.
     

    Laser diode life

    For all intents and purposes, laser diodes in properly designed circuits do not degrade significantly during use or when powered on or off. However, it doesn't take much to blow them (see the section: Laser diode fundamentals). I have seen CD players go more than 10,000 hours with no noticeable change in performance. This doesn't necessarily mean that the laser diode itself isn't gradually degrading in some way - just that the automatic power control is still able to compensate fully. However, this is a lower bound on possible laser diode life span.
    Laser diodes that fail or weaken prematurely were either defective to begin with or, their driver circuitry was inadequate, or they experience some 'event' such as a power-on transient resulting in momentary overcurrent, possibly as short as a few nanoseconds in length! As noted elsewhere, a weak laser diode is well down on the list of likely causes for CD player problems. Of course, in the grand scheme of things, even LEDs gradually lose brightness with use. However, this is another area where manufacturers can cut corners - see the next section.

    Comments on CD player/laser life 


    I did a check on several manufactures expected laser output life. Note this does not relate to the life of the mechanical parts of the optical pickup assembly itself.
    The usable laser output light level is that which the electronics and light sensors can still reliably detect the rf pattern returning off the disc. A new laser in most units optimally will give 1.5 V p-p RF level, while the threshold for failure is around 0.95 V p-p. (This is why many CD players cannot reliably play CD-R's as they have between 60% and 80% reflectivity of a normal CD). Non-officially acknowledged hours rating from a MAJOR CD/LD player manufacture: A few years ago most manufactures of consumer grade cd players reduced the quality of the laser to around 7,000 hours usable output. This is a light bulb in a sense and all light sources will eventually degrade. The laser has an auto power circuit to maintain the proper calibrated light output and the laser power should NEVER be increased may already be operating near the point at which the laser is damaged. The temperature of the laser diode also increase and as the laser gets warm the light output will decrease. I have seen this many times by monitoring the RF level while playing a reference disc and heating up the unit with a hair dryer in those old units that come in saying skips and stops playing after an hour or so. Today many el-cheapo units has rated laser light output life of between 700 and 3000 hours. Yes, really that low. Even 7,000 hours comes out to 9.5 months if the unit is playing 24 hours a day. I cannot tell you how many of these consumer grade units I have had businesses bring in that was playing music on hold all the time, then having to tell them it is not a warranty failure due to excessive use and using a consumer product in a commercial application (all warranties on consumer goods specifically exclude this type of use) It is very possible that due to the large air vents required on boomboxes due to the heat generated by the audio output IC, that a lot of dirt gets into the inside of the optical assembly. For example, 99% of the Aiwa units we get in for repair wind up needing new optics to make the play reliably again as the dirt has caused too much internal damage to the delicate optical pickup mechanism. Sony acknowledges that over 90% of the optics they test come out good on tests, but still replacing them fixed the 'skipping' problem in any given cd player. The number one failure I was seeing with optics was not the laser diode output, but from the internal grating lens shifting inside the optics (usually from the glue holding the internal grating lens in place had cracked and come loose). The second failure I would see would be an open focus coil. This was due to poor design where the combo unit would spike the focus coil with full dc b+ on power on of the unit, causing it to exceed its mechanical limits and heat up the windings. The only case of actual worn out lasers I have seen was in a big box RCA marketed made in China combo stereo. Whenever the unit was plugged in, the laser was on, when the amplifier was turned on the laser would get spiked with large DC voltage. The unit was suppose to have been an exchange in warranty unit, but they had to make it a repair item and supply the modification entire cd mechanisms with circuit board and an auxiliary circuit board as well. LD players due to the larger optical pickup assembly used and the higher cost design of the unit are made to last MUCH longer than the normal el-cheapo cd player. DVD players on the other hand are currently being made so cheaply that we are commonly seeing them in for repair JUST out of warranty with weak lasers (even from major manufactures). Just look at this Oritron super junk DVD brand that is currently on the market right now. Get real: $125 for a DVD player, what kind of junk is it really. I have a friend that works at the local Best Buy service desk and asked him after seeing a pile of these units that have been returned about them, most of them actually have problems within the first week that need to be sent back to the manufacturer for repair. No actual parts or service literature is available for these units.

    CW Laser Light (reverse engineered from commercial unit)

    This circuit was traced from a commercial CW laser light. Errors may have been made in the transcription. The type and specifications for the laser diode assembly (LD and PD) are unknown. The available output power is unknown but the circuit should be suitable for the typical 3-5 mW visible or IR laser diode (assuming the same polarity of LD and PD or with suitable modifications for different polarity units.)
    If you do build this or any other circuit for driving a laser diode, I suggest testing it first with an LED and discrete photodiode to verify current limited operation. Them with the laser diode in place, start with a low voltage supply rather than 9V until you have determined optimal settings and work up gradually. Laser diodes are very unforgiving. Note the heavy capacitive filtering. Changes would be needed to enable this circuit to be modulated at any reasonable rate.
               D1
     +9 >------|>|-------+------------+-----------------+-----+--------+
             1N4001      |            |                 |     |        |
             Reverse     |            |      Pwr Adj    |    _|_     __|__
            Protectio n  |            /      R3 10K (2) | PD /_\  LD _\_/_
                         |        R2  \     +----+      |     |        |
                         |       560  /     |    V      +-----|---||---+
                         |            \     +---/\/\--+-------+   C4   |
                         |            |     |         |          .1 uF |
                         |+           |     |         +----||----+     |
                       __|__          |     |       __|__  C2 (1)|     /
                    C1 -----          |     |     E /   \  100 pF|     \
                   10 uF | -          +-----|------' Q1  '-------+     / R4
                         |            |     |    BC328-25 (5)    |     \ 3.9
                         |            |     |       (PNP)        |     |
                         |            |     |                    |     |
                         |        +---+     |                    |   |/ Q2
                         |        |_ _|_i   |                    +---|  BD139 (NPN)
                         |     VR1  _/_\_   |                   +|   |\ (5)
                         |    LM431   |     |              C3  __|__  E|
                         |    2.5 V   |     |           10 uF  -----   |
                         |    (3)     |     |                   -|     |
              R1 3.9     |            |     |                    |     |
     GND >----/\/\/\-----+------------+-----+--------------------+-----+
    
    
    Notes:
    1. Capacitor C4 value estimated.
    2. Potentiometer R3 measured at 6K.
    3. LM431 shunt regulator set up as 2.5 V zener.
    4. Supply current measured at 150 mA (includes power on LED not shown).
    5. Transistor types do not appear to be critical.

    Use of a CD, CDROM, CD-R, or DVD disc as diffraction grating

    You have no doubt been impressed by the neat and nifty rainbow patterns seen in the reflection off of a compact disc. This is due to the effect of the closely spaced rows of pits acting like a diffraction grating.
    How good is it? I tried an informal experiment with both a normal music CD and a partly recorded CD-R (using the label side of the CD-R as the green layer on the back is a great filter for 632.8 nm HeNe laser light!). Both types worked quite well as reflection gratings with very sharply defined 1st and 2nd order beams from a collimated HeNe laser. There was a slight amount of spread in the direction parallel to the tracks of the CD and this was more pronounced with the music CD, presumably caused by the effectively random data pits. Note that there is usually no truly blank area on a normal CD - the area beyond the music is usually recorded with 0s which with the coding used, are neither blank nor a nice repeating pattern. The CD-R starts out pregrooved so that the CD-writer servo systems can follow the tracks while recording. There is no noticeable change to the label-side as a result of recording on a CD-R. The track pitch on a CD is about 1.6 um or about 625 grooves/mm, quite comparable to some of the commercial gratings from Edmund Scientific or elsewhere. (Note that this is the nominal specification but may vary somewhat and will be less on those CDs that contain more than 74 minutes if music or 650 MB of data but it is probably constant for any give CD.) For a 1 mm HeNe spot, the curvature of the tracks is totally inconsequential. However, for larger area beams, this will have to be taken into account - using outer tracks will be better. The 'tracks' on a DVD are much closer together - 0.74 um compared to 1.6 um for a CD. Since this spacing is very close to the 632.8 nm wavelength of a HeNe laser, only the 0th and first order spots will be present and the first order spots will be at a large angle - 59 degrees *within* the polycarbonate substrate. This becomes an even larger angle when they exit due to the refraction from the surface. At this extreme angle, the spots are weak and distorted. The typically longer wavelength of a laser pointer (up to 670 nm or more) would be even worse. Shorter wavelengths (like that of a green HeNe laser at 543.5 nm) would result in a smaller angle and cleaner spots. Interestingly, on my DVD demo disc, the reflection from the label-side also shows a rainbow pattern but it has a track spacing consistent with the CD rather than DVD format. (The DVD is a sandwich of two 0.6 mm thick polycarbonate substrates with the information on their inner surfaces allowing for either a single or double-sided disc. In the case the pattern for the label-side is just there for decoration!) Most other optical media can be used as diffraction gratings as well. DVDs (Digital Versatile Discs) in particular should be even better at this as their tracks are much closer together than those on CDs :-). If you can figure out a non-destructive way of removing the label, top lacquer layer, and aluminum coating, the result should be a decent transmission type grating. Here's one approach
     
    The following works for pressed CDs with aluminum coatings, but not for CD-Rs or other media with dye-based information layers.
    Take some white vinegar (dilute acetic acid, available at any grocery store), and pour some into a shallow dish at least 6" diameter. Float the CD, label side down, on the surface. Put a cover over the dish. For 2 or 3 days nothing will happen. Then, the acid will start to attack the Al through pinholes in the lacquer. Once that starts, in a few more days most or all of the Al will be gone, and you will have: (1) a decal that was once the label, and (2) a very clean transmission grating. There are lots of interesting things to observe with these gratings, that would make excellent science projects for middle school or even well motivated elementary school students.  

    Rubber belts in CD players

    The type of belts used in CD players for drawer loading and sometimes elsewhere is nearly always a type with a square cross section. Obtaining an exact replacement belt may be difficult and not really necessary.
    Measure the old belt and select one from a parts supplier like MCM Electronics which is as close as possible - equal or slightly greater thickness and an inside circumference (this is how they are measured) such that it will be tight but not so tight as to slow the motor or cause damage to the bearings. This usually means about 5 to 10 percent less than the old (stretched) belt.

    Interchangeability of electronic and mechanical components

    The question often arises: If I cannot obtain an exact replacement or if I have a CD, VCR, or other equipment carcass gathering dust, can I substitute a part that is not a precise match? Sometimes, this is simply desired to confirm a diagnosis and avoid the risk of ordering an expensive replacement and/or having to wait until it arrives.
    For safety related items, the answer is generally NO - an exact replacement part is needed to maintain the specifications within acceptable limits with respect to line isolation, X-ray protection and to minimize fire hazards. However, these components are rare in CD players. Although only a few manufacturers produce most of the components in CD players and CDROM drives, don't expect a lot of readily interchangeable parts other than the common electronic ones listed below. In their never ending search for cost reductions and technology improvements, manufacturers are constantly tweaking their designs. More and more circuitry is finding its way into custom VLSI chips. Fortunately, these do not fail too often. The only parts that are fairly standardized aside from the electronic components are motors. Often, if the motor is physically interchangeable, then it will work as a replacement. Electronic components and entire circuit boards (if identical models and production run) can often be substituted without difficulty though servo alignment will probably be needed due to slight unavoidable differences between apparently identical pickups or electronic components. For common components, whether a not quite identical substitute will work reliably or at all depends on many factors. Except for the optical pickup, non-custom components in CD players are fairly standard. Here are some guidelines:
    1. Fuses - exact same current rating and at least equal voltage rating. I have often soldered a normal 3AG size fuse onto a smaller blown 20 mm long fuse as a substitute.
    2. Resistors, capacitors, inductors, diodes, switches, potentiometers, LEDs, and other common parts - except for those specifically marked as safety-critical - substitution as long as the replacement part fits and specifications should be fine. It is best to use the same type - metal film resistor, for example. But for testing, even this is not a hard and fast rule and a carbon resistor should work just fine.
    3. Rectifiers - replacements should have at equal or better PRV and Imax specifications. For power supply rectifiers, 1N400x types can usually be used.
    4. Transistors - substitutes will generally work as long as their specifications meet or exceed those of the original. For testing, it is usually ok to use types that do not quite meet all of these as long as the BVceo and Ic specifications are not exceeded. However, performance may not be quite as good. For power types, make sure to use a heatsink.
    5. Motors - small PM motors may be substituted if they fit physically and their winding resistance are reasonably similar (say, within 25 percent of one-another). Brushless DC spindle motors are not usually interchangeable.
    6. Sensors - many are sufficiently similar to permit substitution.
    7. Power transformers - in some cases, these may be sufficiently similar that a substitute will work. However, make sure you test for compatible output voltages to avoid damage to the regulator(s) and rest of the circuitry.
    8. Belts - a close match should be good enough at least to confirm a problem or to use until the replacements arrives.
    9. Mechanical parts like screws, flat and split washers, C- and E-clips, and springs - these can often be salvaged from another unit.
    10. Optical pickups - see the section below: "Interchangeability of components in the optical pickup".
    The following are usually custom parts and substitution of something from your junk box is unlikely to be successful even for testing: microcontrollers, other custom programmed chips, display modules; and entire optical pickups, optical decks, or power supplies unless identical.

    Interchangeability of components in the optical pickup

    Once you have located a problem in the optical pickup, what should you do? The quick answer is: probably nothing. In the end any such attempts may simply prove too time consuming and frustrating.
    For parts like laser diodes and photodiode arrays, there are probably too many variables to consider and the labor and risks involved - even for the do-it-yourselfer - would likely be unacceptably high. As an example, the laser diode, which is an expensive component you might be tempted to attempt replacing with one from another pickup (1) may not fit physically, (2) may have different polarity laser diode and photodiode inside the case, (3) may have a very different threshold current and safe operating current, and (4) may have a different optical alignment with respect to any index marks. Any of these would likely make the interchange virtually impossible. The only possibility like to have any chance of success would be to replace the laser diode with a known working device from another *identical* pickup. This is known to work for at least some models but I wouldn't guarantee its success in general. The only breakdown below the pickup level that I would consider as having a reasonable chance of success would be to swap the lens assembly including focus and tracking coils between identical pickups. The optical alignment is not supercritical at this point. However, servo alignment might be needed after this exchange. See the section: Aligning the lens assembly after replacement. One style of lens assembly found in many (Sony) pickups is mounted with two tiny Torx style screws from the top of the optical block. Pop the black plastic cover and you will see these at the end opposite the lens. A small straight blade screwdriver or 0.7 mm hex wrench may work in place of the Torx. Unsolder the four connections for the focus and tracking coils and the entire lens assembly can be removed without disturbing anything else. (Yeh, right, like anyone would actually go to all this trouble!). The lens assembly may be mounted on a platform that is fastened with three screws - two which affect optical alignment from the bottom and a spring loaded screw from the top. Once the alignment is set at the factory, the lens assembly is fixed in place with adhesive. It should not need to be touched. Thus, interchange of these lens assemblies is possible but expect to spend a lazy afternoon or more :-(. However, you will probably wish you had that friendly unemployed Swiss Watchmaker for your assistant. If you have narrowed the problem down to the pickup and you have an identical pickup which you believe to be functional, the best bet is to exchange the entire pickup as a unit. Only minimal servo system alignment would likely be needed after such a replacement. The only optical adjustment needed might be the setting making the beam perpendicular to the disc surface - possibly a hexagonal nut on the bottom of the deck. Be careful with respect to static discharge which could destroy the laser diode. Sometimes, the cable carrying the laser drive voltage has a pair of solder pads to short while handling the pickup not connected to the electronics board. Take care not to rip any of the fine ribbon or other electrical cables and avoid damaging the delicate lens assembly. One other risk is that the laser power adjustment may be set too high for your new pickup - especially if you had turned it up in an effort to revive a weak laser diode. Better yet is to replace the entire optical deck as a unit. This is a lot less work and there is no risk of optical alignment problems at all. Then, only (probably minor) servo alignment may be needed. If you are lucky, the design of your player will even permit you to twiddle the servo adjustment screws while attempting to play a disc (with all the wiring in place) - which is really handy. Also see the section: Test CDs.

    Aligning the lens assembly after replacement

    Should you need to remove the lens assembly from a Sony or other optical pickup, it will need to be replaced in *precisely* the same position, accurate to 0.1 mm or better. Unless it is keyed in place to begin with, this will require monitoring of the return beam and maximizing the amplitude of the sum of the photodiodes A,B,C,D from a mirror or disc.
    First of all, hope you never have to deal with this! Second, it may be fundamentally impossible to accomplish with a disc in place unless you are the size of a dust mite and can fit between the CD and the pickup! Finally, a minor miracle may also be required and it is best to arrange for this ahead of time :-). If you get mostly one type of pickup, then you can build a test device which would power the laser and and provide a test point to monitor the combined photodiode current. In principle, it is simple. In practice you will most likely need a custom device for each type of pickup. With some CD players, you can do this in test mode and monitor the RF while adjusting the alignment.

    Recommended parts suppliers

    For general electronic components like resistors and capacitors, most electronics distributors will have a sufficient variety at reasonable cost. Even Radio Shack can be considered in a pinch.
     
     
     
     Hasil gambar untuk electronic circuit cd room 
     
      Gambar terkait 
     
      Gambar terkait 
     
       Hasil gambar untuk electronic circuit cd room  
    Hasil gambar untuk electronic circuit cd room  
     
       
           Hasil gambar untuk electronic circuit cd room 
     
     
    =================== OPTIC DISC THE MATIC ====================